Cargando…

Technical note: sensitivity analysis of the SCoRE and SARA methods for determining rotational axes during tibiofemoral movements using optical motion capture

PURPOSE: The first aim was to report the sensitivity of calculated tibiofemoral movements for the choice of placement of the set of femoral markers. The second aim was to report the influence of accuracy of the motion captured positions of the markers on the calculated tibiofemoral movements. METHOD...

Descripción completa

Detalles Bibliográficos
Autores principales: Keizer, Michèle N. J., Otten, Egbert
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7010897/
https://www.ncbi.nlm.nih.gov/pubmed/32040787
http://dx.doi.org/10.1186/s40634-020-0219-z
_version_ 1783495962900037632
author Keizer, Michèle N. J.
Otten, Egbert
author_facet Keizer, Michèle N. J.
Otten, Egbert
author_sort Keizer, Michèle N. J.
collection PubMed
description PURPOSE: The first aim was to report the sensitivity of calculated tibiofemoral movements for the choice of placement of the set of femoral markers. The second aim was to report the influence of accuracy of the motion captured positions of the markers on the calculated tibiofemoral movements. METHODS: Tibiofemoral kinematics during single leg hops for distance were calculated. For the first aim, an experiment was conducted in which four different setups of the femoral markers were used to calculated tibiofemoral movements. For the second aim, an experiment was conducted in which all raw marker positions were mathematically moved independently with the known Vicon position error with a distance and in a random direction in each frame, repeated a hundred times. Each time, the tibiofemoral movements were calculated. RESULTS: The first experiment yields that the standard deviation of the calculated anterior tibia translation between marker setups was 0.88 mm and the standard deviation of the external tibia rotation between marker setups was 0.76 degrees. The second experiment yields that the standard deviation was 0.76 mm for anterior tibia translation and 0.38 degrees for external tibia rotation. CONCLUSION: A combined standard deviation of both experiments revealed that transients in anterior tibia translation less than 2.32 mm and external tibia rotations less than 1.70 degrees should be taken with caution. These results are 19.42% of the range of the anterior tibia translation and 13.51% of the rotation range during the jump task. The marker setup should be chosen carefully.
format Online
Article
Text
id pubmed-7010897
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-70108972020-02-25 Technical note: sensitivity analysis of the SCoRE and SARA methods for determining rotational axes during tibiofemoral movements using optical motion capture Keizer, Michèle N. J. Otten, Egbert J Exp Orthop Research PURPOSE: The first aim was to report the sensitivity of calculated tibiofemoral movements for the choice of placement of the set of femoral markers. The second aim was to report the influence of accuracy of the motion captured positions of the markers on the calculated tibiofemoral movements. METHODS: Tibiofemoral kinematics during single leg hops for distance were calculated. For the first aim, an experiment was conducted in which four different setups of the femoral markers were used to calculated tibiofemoral movements. For the second aim, an experiment was conducted in which all raw marker positions were mathematically moved independently with the known Vicon position error with a distance and in a random direction in each frame, repeated a hundred times. Each time, the tibiofemoral movements were calculated. RESULTS: The first experiment yields that the standard deviation of the calculated anterior tibia translation between marker setups was 0.88 mm and the standard deviation of the external tibia rotation between marker setups was 0.76 degrees. The second experiment yields that the standard deviation was 0.76 mm for anterior tibia translation and 0.38 degrees for external tibia rotation. CONCLUSION: A combined standard deviation of both experiments revealed that transients in anterior tibia translation less than 2.32 mm and external tibia rotations less than 1.70 degrees should be taken with caution. These results are 19.42% of the range of the anterior tibia translation and 13.51% of the rotation range during the jump task. The marker setup should be chosen carefully. Springer Berlin Heidelberg 2020-02-10 /pmc/articles/PMC7010897/ /pubmed/32040787 http://dx.doi.org/10.1186/s40634-020-0219-z Text en © The Author(s) 2020 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Research
Keizer, Michèle N. J.
Otten, Egbert
Technical note: sensitivity analysis of the SCoRE and SARA methods for determining rotational axes during tibiofemoral movements using optical motion capture
title Technical note: sensitivity analysis of the SCoRE and SARA methods for determining rotational axes during tibiofemoral movements using optical motion capture
title_full Technical note: sensitivity analysis of the SCoRE and SARA methods for determining rotational axes during tibiofemoral movements using optical motion capture
title_fullStr Technical note: sensitivity analysis of the SCoRE and SARA methods for determining rotational axes during tibiofemoral movements using optical motion capture
title_full_unstemmed Technical note: sensitivity analysis of the SCoRE and SARA methods for determining rotational axes during tibiofemoral movements using optical motion capture
title_short Technical note: sensitivity analysis of the SCoRE and SARA methods for determining rotational axes during tibiofemoral movements using optical motion capture
title_sort technical note: sensitivity analysis of the score and sara methods for determining rotational axes during tibiofemoral movements using optical motion capture
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7010897/
https://www.ncbi.nlm.nih.gov/pubmed/32040787
http://dx.doi.org/10.1186/s40634-020-0219-z
work_keys_str_mv AT keizermichelenj technicalnotesensitivityanalysisofthescoreandsaramethodsfordeterminingrotationalaxesduringtibiofemoralmovementsusingopticalmotioncapture
AT ottenegbert technicalnotesensitivityanalysisofthescoreandsaramethodsfordeterminingrotationalaxesduringtibiofemoralmovementsusingopticalmotioncapture