Cargando…
Coregistered optical coherence tomography and frequency-encoded multispectral imaging for spectrally sparse color imaging
We present a system combining optical coherence tomography (OCT) and multispectral imaging (MSI) for coregistered structural imaging and surface color imaging. We first describe and numerically validate an optimization model to guide the selection of the MSI wavelengths and their relative intensitie...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Society of Photo-Optical Instrumentation Engineers
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7011031/ https://www.ncbi.nlm.nih.gov/pubmed/31755250 http://dx.doi.org/10.1117/1.JBO.25.3.032008 |
_version_ | 1783495990781673472 |
---|---|
author | Attendu, Xavier Bourget, Marie-Hélène de Sivry-Houle, Martin Poinsinet Boudoux, Caroline |
author_facet | Attendu, Xavier Bourget, Marie-Hélène de Sivry-Houle, Martin Poinsinet Boudoux, Caroline |
author_sort | Attendu, Xavier |
collection | PubMed |
description | We present a system combining optical coherence tomography (OCT) and multispectral imaging (MSI) for coregistered structural imaging and surface color imaging. We first describe and numerically validate an optimization model to guide the selection of the MSI wavelengths and their relative intensities. We then demonstrate the integration of this model into an all-fiber bench-top system. We implement frequency-domain multiplexing for the MSI to enable concurrent acquisition of both OCT and MSI at OCT acquisition rates. Such a system could be implemented in endoscopic practices to provide multimodal, high-resolution imaging of deep organ structures that are currently inaccessible to standard video endoscopes. |
format | Online Article Text |
id | pubmed-7011031 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Society of Photo-Optical Instrumentation Engineers |
record_format | MEDLINE/PubMed |
spelling | pubmed-70110312020-02-14 Coregistered optical coherence tomography and frequency-encoded multispectral imaging for spectrally sparse color imaging Attendu, Xavier Bourget, Marie-Hélène de Sivry-Houle, Martin Poinsinet Boudoux, Caroline J Biomed Opt Special Section on Biomedical Imaging and Sensing We present a system combining optical coherence tomography (OCT) and multispectral imaging (MSI) for coregistered structural imaging and surface color imaging. We first describe and numerically validate an optimization model to guide the selection of the MSI wavelengths and their relative intensities. We then demonstrate the integration of this model into an all-fiber bench-top system. We implement frequency-domain multiplexing for the MSI to enable concurrent acquisition of both OCT and MSI at OCT acquisition rates. Such a system could be implemented in endoscopic practices to provide multimodal, high-resolution imaging of deep organ structures that are currently inaccessible to standard video endoscopes. Society of Photo-Optical Instrumentation Engineers 2019-11-21 2020-03 /pmc/articles/PMC7011031/ /pubmed/31755250 http://dx.doi.org/10.1117/1.JBO.25.3.032008 Text en © 2020 The Authors https://creativecommons.org/licenses/by/4.0/ Published by SPIE under a Creative Commons Attribution 4.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI. |
spellingShingle | Special Section on Biomedical Imaging and Sensing Attendu, Xavier Bourget, Marie-Hélène de Sivry-Houle, Martin Poinsinet Boudoux, Caroline Coregistered optical coherence tomography and frequency-encoded multispectral imaging for spectrally sparse color imaging |
title | Coregistered optical coherence tomography and frequency-encoded multispectral imaging for spectrally sparse color imaging |
title_full | Coregistered optical coherence tomography and frequency-encoded multispectral imaging for spectrally sparse color imaging |
title_fullStr | Coregistered optical coherence tomography and frequency-encoded multispectral imaging for spectrally sparse color imaging |
title_full_unstemmed | Coregistered optical coherence tomography and frequency-encoded multispectral imaging for spectrally sparse color imaging |
title_short | Coregistered optical coherence tomography and frequency-encoded multispectral imaging for spectrally sparse color imaging |
title_sort | coregistered optical coherence tomography and frequency-encoded multispectral imaging for spectrally sparse color imaging |
topic | Special Section on Biomedical Imaging and Sensing |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7011031/ https://www.ncbi.nlm.nih.gov/pubmed/31755250 http://dx.doi.org/10.1117/1.JBO.25.3.032008 |
work_keys_str_mv | AT attenduxavier coregisteredopticalcoherencetomographyandfrequencyencodedmultispectralimagingforspectrallysparsecolorimaging AT bourgetmariehelene coregisteredopticalcoherencetomographyandfrequencyencodedmultispectralimagingforspectrallysparsecolorimaging AT desivryhoulemartinpoinsinet coregisteredopticalcoherencetomographyandfrequencyencodedmultispectralimagingforspectrallysparsecolorimaging AT boudouxcaroline coregisteredopticalcoherencetomographyandfrequencyencodedmultispectralimagingforspectrallysparsecolorimaging |