Cargando…
Surgical outcomes of elderly patients aged more than 80 years with distal radius fracture: comparison of external fixation and locking plate
BACKGROUND: To compare the outcomes after surgical intervention, including external fixation (EF) with the optional addition of K-pins or open reduction and internal fixation (ORIF) with a volar locking plate (VLP), in patients with distal radius fracture aged > 80 years. METHODS: We reviewed 69...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7011248/ https://www.ncbi.nlm.nih.gov/pubmed/32041567 http://dx.doi.org/10.1186/s12891-020-3101-3 |
_version_ | 1783496030854053888 |
---|---|
author | Huang, Yu-Yi Lin, Tung-Yi Chen, Chien-Hao Chou, Ying-Chao Su, Chun-Yi |
author_facet | Huang, Yu-Yi Lin, Tung-Yi Chen, Chien-Hao Chou, Ying-Chao Su, Chun-Yi |
author_sort | Huang, Yu-Yi |
collection | PubMed |
description | BACKGROUND: To compare the outcomes after surgical intervention, including external fixation (EF) with the optional addition of K-pins or open reduction and internal fixation (ORIF) with a volar locking plate (VLP), in patients with distal radius fracture aged > 80 years. METHODS: We reviewed 69 patients with a distal radius fracture aged > 80 years who treated under surgical intervention from 2011 to 2017 retrospectively. Their demographic data and complications were recorded. Preoperative, postoperative, and last follow-up plain films were analyzed. The functional outcomes of wrist range of motion were also evaluated. RESULTS: 41 patients were treated with EF with the optional addition of K-pins, while 28 patients were treated with ORIF with a VLP. The radiological parameters, including ulnar variance and radial inclination, at the last follow-up were significantly more acceptable in the VLP group (p = 0.01, p = 0.03, respectively). The forearm supination was significantly better in patients treated with VLP (p = 0.002). The overall incidence of complications was lower in the VLP group (p = 0.003). CONCLUSION: VLP provides better radiological outcomes, wrist supination and lower complication rates than EF. Therefore, although EF is still widely used because of its acceptable results and easy application, we recommend VLP as a suitable treatment option for distal radius fracture in the geriatric population aged > 80 years. |
format | Online Article Text |
id | pubmed-7011248 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-70112482020-02-14 Surgical outcomes of elderly patients aged more than 80 years with distal radius fracture: comparison of external fixation and locking plate Huang, Yu-Yi Lin, Tung-Yi Chen, Chien-Hao Chou, Ying-Chao Su, Chun-Yi BMC Musculoskelet Disord Research Article BACKGROUND: To compare the outcomes after surgical intervention, including external fixation (EF) with the optional addition of K-pins or open reduction and internal fixation (ORIF) with a volar locking plate (VLP), in patients with distal radius fracture aged > 80 years. METHODS: We reviewed 69 patients with a distal radius fracture aged > 80 years who treated under surgical intervention from 2011 to 2017 retrospectively. Their demographic data and complications were recorded. Preoperative, postoperative, and last follow-up plain films were analyzed. The functional outcomes of wrist range of motion were also evaluated. RESULTS: 41 patients were treated with EF with the optional addition of K-pins, while 28 patients were treated with ORIF with a VLP. The radiological parameters, including ulnar variance and radial inclination, at the last follow-up were significantly more acceptable in the VLP group (p = 0.01, p = 0.03, respectively). The forearm supination was significantly better in patients treated with VLP (p = 0.002). The overall incidence of complications was lower in the VLP group (p = 0.003). CONCLUSION: VLP provides better radiological outcomes, wrist supination and lower complication rates than EF. Therefore, although EF is still widely used because of its acceptable results and easy application, we recommend VLP as a suitable treatment option for distal radius fracture in the geriatric population aged > 80 years. BioMed Central 2020-02-10 /pmc/articles/PMC7011248/ /pubmed/32041567 http://dx.doi.org/10.1186/s12891-020-3101-3 Text en © The Author(s). 2020 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Huang, Yu-Yi Lin, Tung-Yi Chen, Chien-Hao Chou, Ying-Chao Su, Chun-Yi Surgical outcomes of elderly patients aged more than 80 years with distal radius fracture: comparison of external fixation and locking plate |
title | Surgical outcomes of elderly patients aged more than 80 years with distal radius fracture: comparison of external fixation and locking plate |
title_full | Surgical outcomes of elderly patients aged more than 80 years with distal radius fracture: comparison of external fixation and locking plate |
title_fullStr | Surgical outcomes of elderly patients aged more than 80 years with distal radius fracture: comparison of external fixation and locking plate |
title_full_unstemmed | Surgical outcomes of elderly patients aged more than 80 years with distal radius fracture: comparison of external fixation and locking plate |
title_short | Surgical outcomes of elderly patients aged more than 80 years with distal radius fracture: comparison of external fixation and locking plate |
title_sort | surgical outcomes of elderly patients aged more than 80 years with distal radius fracture: comparison of external fixation and locking plate |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7011248/ https://www.ncbi.nlm.nih.gov/pubmed/32041567 http://dx.doi.org/10.1186/s12891-020-3101-3 |
work_keys_str_mv | AT huangyuyi surgicaloutcomesofelderlypatientsagedmorethan80yearswithdistalradiusfracturecomparisonofexternalfixationandlockingplate AT lintungyi surgicaloutcomesofelderlypatientsagedmorethan80yearswithdistalradiusfracturecomparisonofexternalfixationandlockingplate AT chenchienhao surgicaloutcomesofelderlypatientsagedmorethan80yearswithdistalradiusfracturecomparisonofexternalfixationandlockingplate AT chouyingchao surgicaloutcomesofelderlypatientsagedmorethan80yearswithdistalradiusfracturecomparisonofexternalfixationandlockingplate AT suchunyi surgicaloutcomesofelderlypatientsagedmorethan80yearswithdistalradiusfracturecomparisonofexternalfixationandlockingplate |