Cargando…
Hurdle Clearance Detection and Spatiotemporal Analysis in 400 Meters Hurdles Races Using Shoe-Mounted Magnetic and Inertial Sensors
This research aimed to determine whether: (1) shoe-worn magnetic and inertial sensors can be used to detect hurdle clearance and identify the leading leg in 400-m hurdles, and (2) to provide an analysis of the hurdlers’ spatiotemporal parameters in the intervals defined by the hurdles’ position. The...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7013538/ https://www.ncbi.nlm.nih.gov/pubmed/31936395 http://dx.doi.org/10.3390/s20020354 |
_version_ | 1783496426262626304 |
---|---|
author | Falbriard, Mathieu Mohr, Maurice Aminian, Kamiar |
author_facet | Falbriard, Mathieu Mohr, Maurice Aminian, Kamiar |
author_sort | Falbriard, Mathieu |
collection | PubMed |
description | This research aimed to determine whether: (1) shoe-worn magnetic and inertial sensors can be used to detect hurdle clearance and identify the leading leg in 400-m hurdles, and (2) to provide an analysis of the hurdlers’ spatiotemporal parameters in the intervals defined by the hurdles’ position. The data set is composed of MIMU recordings of 15 athletes in a competitive environment. The results show that the method based on the duration of the flight phase was able to detect hurdle clearance and identify the leading leg with 100% accuracy. Moreover, by combining the swing phase duration with the orientation of the foot, we achieved, in unipedal configuration, 100% accuracy in hurdle clearance detection, and 99.7% accuracy in the identification of the leading leg. Finally, this study provides statistical evidence that contact time significantly increases, while speed and step frequency significantly decrease with time during 400 m hurdle races. |
format | Online Article Text |
id | pubmed-7013538 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-70135382020-03-09 Hurdle Clearance Detection and Spatiotemporal Analysis in 400 Meters Hurdles Races Using Shoe-Mounted Magnetic and Inertial Sensors Falbriard, Mathieu Mohr, Maurice Aminian, Kamiar Sensors (Basel) Article This research aimed to determine whether: (1) shoe-worn magnetic and inertial sensors can be used to detect hurdle clearance and identify the leading leg in 400-m hurdles, and (2) to provide an analysis of the hurdlers’ spatiotemporal parameters in the intervals defined by the hurdles’ position. The data set is composed of MIMU recordings of 15 athletes in a competitive environment. The results show that the method based on the duration of the flight phase was able to detect hurdle clearance and identify the leading leg with 100% accuracy. Moreover, by combining the swing phase duration with the orientation of the foot, we achieved, in unipedal configuration, 100% accuracy in hurdle clearance detection, and 99.7% accuracy in the identification of the leading leg. Finally, this study provides statistical evidence that contact time significantly increases, while speed and step frequency significantly decrease with time during 400 m hurdle races. MDPI 2020-01-08 /pmc/articles/PMC7013538/ /pubmed/31936395 http://dx.doi.org/10.3390/s20020354 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Falbriard, Mathieu Mohr, Maurice Aminian, Kamiar Hurdle Clearance Detection and Spatiotemporal Analysis in 400 Meters Hurdles Races Using Shoe-Mounted Magnetic and Inertial Sensors |
title | Hurdle Clearance Detection and Spatiotemporal Analysis in 400 Meters Hurdles Races Using Shoe-Mounted Magnetic and Inertial Sensors |
title_full | Hurdle Clearance Detection and Spatiotemporal Analysis in 400 Meters Hurdles Races Using Shoe-Mounted Magnetic and Inertial Sensors |
title_fullStr | Hurdle Clearance Detection and Spatiotemporal Analysis in 400 Meters Hurdles Races Using Shoe-Mounted Magnetic and Inertial Sensors |
title_full_unstemmed | Hurdle Clearance Detection and Spatiotemporal Analysis in 400 Meters Hurdles Races Using Shoe-Mounted Magnetic and Inertial Sensors |
title_short | Hurdle Clearance Detection and Spatiotemporal Analysis in 400 Meters Hurdles Races Using Shoe-Mounted Magnetic and Inertial Sensors |
title_sort | hurdle clearance detection and spatiotemporal analysis in 400 meters hurdles races using shoe-mounted magnetic and inertial sensors |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7013538/ https://www.ncbi.nlm.nih.gov/pubmed/31936395 http://dx.doi.org/10.3390/s20020354 |
work_keys_str_mv | AT falbriardmathieu hurdleclearancedetectionandspatiotemporalanalysisin400metershurdlesracesusingshoemountedmagneticandinertialsensors AT mohrmaurice hurdleclearancedetectionandspatiotemporalanalysisin400metershurdlesracesusingshoemountedmagneticandinertialsensors AT aminiankamiar hurdleclearancedetectionandspatiotemporalanalysisin400metershurdlesracesusingshoemountedmagneticandinertialsensors |