Cargando…

Hurdle Clearance Detection and Spatiotemporal Analysis in 400 Meters Hurdles Races Using Shoe-Mounted Magnetic and Inertial Sensors

This research aimed to determine whether: (1) shoe-worn magnetic and inertial sensors can be used to detect hurdle clearance and identify the leading leg in 400-m hurdles, and (2) to provide an analysis of the hurdlers’ spatiotemporal parameters in the intervals defined by the hurdles’ position. The...

Descripción completa

Detalles Bibliográficos
Autores principales: Falbriard, Mathieu, Mohr, Maurice, Aminian, Kamiar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7013538/
https://www.ncbi.nlm.nih.gov/pubmed/31936395
http://dx.doi.org/10.3390/s20020354
_version_ 1783496426262626304
author Falbriard, Mathieu
Mohr, Maurice
Aminian, Kamiar
author_facet Falbriard, Mathieu
Mohr, Maurice
Aminian, Kamiar
author_sort Falbriard, Mathieu
collection PubMed
description This research aimed to determine whether: (1) shoe-worn magnetic and inertial sensors can be used to detect hurdle clearance and identify the leading leg in 400-m hurdles, and (2) to provide an analysis of the hurdlers’ spatiotemporal parameters in the intervals defined by the hurdles’ position. The data set is composed of MIMU recordings of 15 athletes in a competitive environment. The results show that the method based on the duration of the flight phase was able to detect hurdle clearance and identify the leading leg with 100% accuracy. Moreover, by combining the swing phase duration with the orientation of the foot, we achieved, in unipedal configuration, 100% accuracy in hurdle clearance detection, and 99.7% accuracy in the identification of the leading leg. Finally, this study provides statistical evidence that contact time significantly increases, while speed and step frequency significantly decrease with time during 400 m hurdle races.
format Online
Article
Text
id pubmed-7013538
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-70135382020-03-09 Hurdle Clearance Detection and Spatiotemporal Analysis in 400 Meters Hurdles Races Using Shoe-Mounted Magnetic and Inertial Sensors Falbriard, Mathieu Mohr, Maurice Aminian, Kamiar Sensors (Basel) Article This research aimed to determine whether: (1) shoe-worn magnetic and inertial sensors can be used to detect hurdle clearance and identify the leading leg in 400-m hurdles, and (2) to provide an analysis of the hurdlers’ spatiotemporal parameters in the intervals defined by the hurdles’ position. The data set is composed of MIMU recordings of 15 athletes in a competitive environment. The results show that the method based on the duration of the flight phase was able to detect hurdle clearance and identify the leading leg with 100% accuracy. Moreover, by combining the swing phase duration with the orientation of the foot, we achieved, in unipedal configuration, 100% accuracy in hurdle clearance detection, and 99.7% accuracy in the identification of the leading leg. Finally, this study provides statistical evidence that contact time significantly increases, while speed and step frequency significantly decrease with time during 400 m hurdle races. MDPI 2020-01-08 /pmc/articles/PMC7013538/ /pubmed/31936395 http://dx.doi.org/10.3390/s20020354 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Falbriard, Mathieu
Mohr, Maurice
Aminian, Kamiar
Hurdle Clearance Detection and Spatiotemporal Analysis in 400 Meters Hurdles Races Using Shoe-Mounted Magnetic and Inertial Sensors
title Hurdle Clearance Detection and Spatiotemporal Analysis in 400 Meters Hurdles Races Using Shoe-Mounted Magnetic and Inertial Sensors
title_full Hurdle Clearance Detection and Spatiotemporal Analysis in 400 Meters Hurdles Races Using Shoe-Mounted Magnetic and Inertial Sensors
title_fullStr Hurdle Clearance Detection and Spatiotemporal Analysis in 400 Meters Hurdles Races Using Shoe-Mounted Magnetic and Inertial Sensors
title_full_unstemmed Hurdle Clearance Detection and Spatiotemporal Analysis in 400 Meters Hurdles Races Using Shoe-Mounted Magnetic and Inertial Sensors
title_short Hurdle Clearance Detection and Spatiotemporal Analysis in 400 Meters Hurdles Races Using Shoe-Mounted Magnetic and Inertial Sensors
title_sort hurdle clearance detection and spatiotemporal analysis in 400 meters hurdles races using shoe-mounted magnetic and inertial sensors
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7013538/
https://www.ncbi.nlm.nih.gov/pubmed/31936395
http://dx.doi.org/10.3390/s20020354
work_keys_str_mv AT falbriardmathieu hurdleclearancedetectionandspatiotemporalanalysisin400metershurdlesracesusingshoemountedmagneticandinertialsensors
AT mohrmaurice hurdleclearancedetectionandspatiotemporalanalysisin400metershurdlesracesusingshoemountedmagneticandinertialsensors
AT aminiankamiar hurdleclearancedetectionandspatiotemporalanalysisin400metershurdlesracesusingshoemountedmagneticandinertialsensors