Estimation of an Upper Bound to the Value of the Step Potentials in Two-Layered Soils from Grounding Resistance Measurements

Due to the constant updating of regulatory standards on safety issues in electrical installations, limits are established for the maximum step potential that an installation can hold in a ground fault situation. In this paper, an upper bound to the maximum value of the step potentials arising in the...

Descripción completa

Detalles Bibliográficos
Autores principales: Moreno, Jorge, Simon, Pascual, Faleiro, Eduardo, Asensio, Gabriel, Fernandez, Jose Antonio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7014292/
https://www.ncbi.nlm.nih.gov/pubmed/31936414
http://dx.doi.org/10.3390/ma13020290
_version_ 1783496596480065536
author Moreno, Jorge
Simon, Pascual
Faleiro, Eduardo
Asensio, Gabriel
Fernandez, Jose Antonio
author_facet Moreno, Jorge
Simon, Pascual
Faleiro, Eduardo
Asensio, Gabriel
Fernandez, Jose Antonio
author_sort Moreno, Jorge
collection PubMed
description Due to the constant updating of regulatory standards on safety issues in electrical installations, limits are established for the maximum step potential that an installation can hold in a ground fault situation. In this paper, an upper bound to the maximum value of the step potentials arising in the soil surface when a fault takes place in a grounded electrical installation is estimated by means of a simple procedure. The direct measurement of the grounding electrode resistance together with some information about the soil resistivity and the knowledge of characteristic parameters of the electrode are used for the calculation of that upper bound. The procedure is tested at numerical simulation level by using different electrodes in several different scenarios corresponding to two-layered soils with different resistivity ratios. The dependency of the calculated upper bound with the electrode burial depth is also studied. Finally, a real case study is presented, and the results of the field measurements are shown as an example of the validity of the procedure.
format Online
Article
Text
id pubmed-7014292
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-70142922020-03-09 Estimation of an Upper Bound to the Value of the Step Potentials in Two-Layered Soils from Grounding Resistance Measurements Moreno, Jorge Simon, Pascual Faleiro, Eduardo Asensio, Gabriel Fernandez, Jose Antonio Materials (Basel) Article Due to the constant updating of regulatory standards on safety issues in electrical installations, limits are established for the maximum step potential that an installation can hold in a ground fault situation. In this paper, an upper bound to the maximum value of the step potentials arising in the soil surface when a fault takes place in a grounded electrical installation is estimated by means of a simple procedure. The direct measurement of the grounding electrode resistance together with some information about the soil resistivity and the knowledge of characteristic parameters of the electrode are used for the calculation of that upper bound. The procedure is tested at numerical simulation level by using different electrodes in several different scenarios corresponding to two-layered soils with different resistivity ratios. The dependency of the calculated upper bound with the electrode burial depth is also studied. Finally, a real case study is presented, and the results of the field measurements are shown as an example of the validity of the procedure. MDPI 2020-01-08 /pmc/articles/PMC7014292/ /pubmed/31936414 http://dx.doi.org/10.3390/ma13020290 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Moreno, Jorge
Simon, Pascual
Faleiro, Eduardo
Asensio, Gabriel
Fernandez, Jose Antonio
Estimation of an Upper Bound to the Value of the Step Potentials in Two-Layered Soils from Grounding Resistance Measurements
title Estimation of an Upper Bound to the Value of the Step Potentials in Two-Layered Soils from Grounding Resistance Measurements
title_full Estimation of an Upper Bound to the Value of the Step Potentials in Two-Layered Soils from Grounding Resistance Measurements
title_fullStr Estimation of an Upper Bound to the Value of the Step Potentials in Two-Layered Soils from Grounding Resistance Measurements
title_full_unstemmed Estimation of an Upper Bound to the Value of the Step Potentials in Two-Layered Soils from Grounding Resistance Measurements
title_short Estimation of an Upper Bound to the Value of the Step Potentials in Two-Layered Soils from Grounding Resistance Measurements
title_sort estimation of an upper bound to the value of the step potentials in two-layered soils from grounding resistance measurements
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7014292/
https://www.ncbi.nlm.nih.gov/pubmed/31936414
http://dx.doi.org/10.3390/ma13020290
work_keys_str_mv AT morenojorge estimationofanupperboundtothevalueofthesteppotentialsintwolayeredsoilsfromgroundingresistancemeasurements
AT simonpascual estimationofanupperboundtothevalueofthesteppotentialsintwolayeredsoilsfromgroundingresistancemeasurements
AT faleiroeduardo estimationofanupperboundtothevalueofthesteppotentialsintwolayeredsoilsfromgroundingresistancemeasurements
AT asensiogabriel estimationofanupperboundtothevalueofthesteppotentialsintwolayeredsoilsfromgroundingresistancemeasurements
AT fernandezjoseantonio estimationofanupperboundtothevalueofthesteppotentialsintwolayeredsoilsfromgroundingresistancemeasurements