Sensor Fault Diagnosis for Impedance Monitoring Using a Piezoelectric-Based Smart Interface Technique

For a structural health monitoring (SHM) system, the operational functionality of sensors is critical for successful implementation of a damage identification process. This study presents experimental and analytical investigations on sensor fault diagnosis for impedance-based SHM using the piezoelec...

Descripción completa

Detalles Bibliográficos
Autores principales: Huynh, Thanh-Canh, Nguyen, The-Duong, Ho, Duc-Duy, Dang, Ngoc-Loi, Kim, Jeong-Tae
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7014494/
https://www.ncbi.nlm.nih.gov/pubmed/31963252
http://dx.doi.org/10.3390/s20020510
_version_ 1783496643606216704
author Huynh, Thanh-Canh
Nguyen, The-Duong
Ho, Duc-Duy
Dang, Ngoc-Loi
Kim, Jeong-Tae
author_facet Huynh, Thanh-Canh
Nguyen, The-Duong
Ho, Duc-Duy
Dang, Ngoc-Loi
Kim, Jeong-Tae
author_sort Huynh, Thanh-Canh
collection PubMed
description For a structural health monitoring (SHM) system, the operational functionality of sensors is critical for successful implementation of a damage identification process. This study presents experimental and analytical investigations on sensor fault diagnosis for impedance-based SHM using the piezoelectric interface technique. Firstly, the piezoelectric interface-based impedance monitoring is experimentally conducted on a steel bolted connection to investigate the effect of structural damage and sensor defect on electromechanical (EM) impedance responses. Based on the experimental analysis, sensor diagnostic approaches using EM impedance features are designed to distinguish the sensor defect from the structural damage. Next, a novel impedance model of the piezoelectric interface-driven system is proposed for the analytical investigation of sensor fault diagnosis. Various parameters are introduced into the EM impedance formulation to model the effect of shear-lag phenomenon, sensor breakage, sensor debonding, and structural damage. Finally, the proposed impedance model is used to analytically estimate the change in EM impedance responses induced by the structural damage and the sensor defect. The analytical results are found to be consistent with experimental observations, thus evidencing the feasibility of the novel impedance model for sensor diagnosis and structural integrity assessment. The study is expected to provide theoretical and experimental foundations for impedance monitoring practices, using the piezoelectric interface technique, with the existence of sensor faults.
format Online
Article
Text
id pubmed-7014494
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-70144942020-03-09 Sensor Fault Diagnosis for Impedance Monitoring Using a Piezoelectric-Based Smart Interface Technique Huynh, Thanh-Canh Nguyen, The-Duong Ho, Duc-Duy Dang, Ngoc-Loi Kim, Jeong-Tae Sensors (Basel) Article For a structural health monitoring (SHM) system, the operational functionality of sensors is critical for successful implementation of a damage identification process. This study presents experimental and analytical investigations on sensor fault diagnosis for impedance-based SHM using the piezoelectric interface technique. Firstly, the piezoelectric interface-based impedance monitoring is experimentally conducted on a steel bolted connection to investigate the effect of structural damage and sensor defect on electromechanical (EM) impedance responses. Based on the experimental analysis, sensor diagnostic approaches using EM impedance features are designed to distinguish the sensor defect from the structural damage. Next, a novel impedance model of the piezoelectric interface-driven system is proposed for the analytical investigation of sensor fault diagnosis. Various parameters are introduced into the EM impedance formulation to model the effect of shear-lag phenomenon, sensor breakage, sensor debonding, and structural damage. Finally, the proposed impedance model is used to analytically estimate the change in EM impedance responses induced by the structural damage and the sensor defect. The analytical results are found to be consistent with experimental observations, thus evidencing the feasibility of the novel impedance model for sensor diagnosis and structural integrity assessment. The study is expected to provide theoretical and experimental foundations for impedance monitoring practices, using the piezoelectric interface technique, with the existence of sensor faults. MDPI 2020-01-16 /pmc/articles/PMC7014494/ /pubmed/31963252 http://dx.doi.org/10.3390/s20020510 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Huynh, Thanh-Canh
Nguyen, The-Duong
Ho, Duc-Duy
Dang, Ngoc-Loi
Kim, Jeong-Tae
Sensor Fault Diagnosis for Impedance Monitoring Using a Piezoelectric-Based Smart Interface Technique
title Sensor Fault Diagnosis for Impedance Monitoring Using a Piezoelectric-Based Smart Interface Technique
title_full Sensor Fault Diagnosis for Impedance Monitoring Using a Piezoelectric-Based Smart Interface Technique
title_fullStr Sensor Fault Diagnosis for Impedance Monitoring Using a Piezoelectric-Based Smart Interface Technique
title_full_unstemmed Sensor Fault Diagnosis for Impedance Monitoring Using a Piezoelectric-Based Smart Interface Technique
title_short Sensor Fault Diagnosis for Impedance Monitoring Using a Piezoelectric-Based Smart Interface Technique
title_sort sensor fault diagnosis for impedance monitoring using a piezoelectric-based smart interface technique
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7014494/
https://www.ncbi.nlm.nih.gov/pubmed/31963252
http://dx.doi.org/10.3390/s20020510
work_keys_str_mv AT huynhthanhcanh sensorfaultdiagnosisforimpedancemonitoringusingapiezoelectricbasedsmartinterfacetechnique
AT nguyentheduong sensorfaultdiagnosisforimpedancemonitoringusingapiezoelectricbasedsmartinterfacetechnique
AT hoducduy sensorfaultdiagnosisforimpedancemonitoringusingapiezoelectricbasedsmartinterfacetechnique
AT dangngocloi sensorfaultdiagnosisforimpedancemonitoringusingapiezoelectricbasedsmartinterfacetechnique
AT kimjeongtae sensorfaultdiagnosisforimpedancemonitoringusingapiezoelectricbasedsmartinterfacetechnique