Cargando…
Sensor Fault Diagnosis for Impedance Monitoring Using a Piezoelectric-Based Smart Interface Technique
For a structural health monitoring (SHM) system, the operational functionality of sensors is critical for successful implementation of a damage identification process. This study presents experimental and analytical investigations on sensor fault diagnosis for impedance-based SHM using the piezoelec...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7014494/ https://www.ncbi.nlm.nih.gov/pubmed/31963252 http://dx.doi.org/10.3390/s20020510 |
_version_ | 1783496643606216704 |
---|---|
author | Huynh, Thanh-Canh Nguyen, The-Duong Ho, Duc-Duy Dang, Ngoc-Loi Kim, Jeong-Tae |
author_facet | Huynh, Thanh-Canh Nguyen, The-Duong Ho, Duc-Duy Dang, Ngoc-Loi Kim, Jeong-Tae |
author_sort | Huynh, Thanh-Canh |
collection | PubMed |
description | For a structural health monitoring (SHM) system, the operational functionality of sensors is critical for successful implementation of a damage identification process. This study presents experimental and analytical investigations on sensor fault diagnosis for impedance-based SHM using the piezoelectric interface technique. Firstly, the piezoelectric interface-based impedance monitoring is experimentally conducted on a steel bolted connection to investigate the effect of structural damage and sensor defect on electromechanical (EM) impedance responses. Based on the experimental analysis, sensor diagnostic approaches using EM impedance features are designed to distinguish the sensor defect from the structural damage. Next, a novel impedance model of the piezoelectric interface-driven system is proposed for the analytical investigation of sensor fault diagnosis. Various parameters are introduced into the EM impedance formulation to model the effect of shear-lag phenomenon, sensor breakage, sensor debonding, and structural damage. Finally, the proposed impedance model is used to analytically estimate the change in EM impedance responses induced by the structural damage and the sensor defect. The analytical results are found to be consistent with experimental observations, thus evidencing the feasibility of the novel impedance model for sensor diagnosis and structural integrity assessment. The study is expected to provide theoretical and experimental foundations for impedance monitoring practices, using the piezoelectric interface technique, with the existence of sensor faults. |
format | Online Article Text |
id | pubmed-7014494 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-70144942020-03-09 Sensor Fault Diagnosis for Impedance Monitoring Using a Piezoelectric-Based Smart Interface Technique Huynh, Thanh-Canh Nguyen, The-Duong Ho, Duc-Duy Dang, Ngoc-Loi Kim, Jeong-Tae Sensors (Basel) Article For a structural health monitoring (SHM) system, the operational functionality of sensors is critical for successful implementation of a damage identification process. This study presents experimental and analytical investigations on sensor fault diagnosis for impedance-based SHM using the piezoelectric interface technique. Firstly, the piezoelectric interface-based impedance monitoring is experimentally conducted on a steel bolted connection to investigate the effect of structural damage and sensor defect on electromechanical (EM) impedance responses. Based on the experimental analysis, sensor diagnostic approaches using EM impedance features are designed to distinguish the sensor defect from the structural damage. Next, a novel impedance model of the piezoelectric interface-driven system is proposed for the analytical investigation of sensor fault diagnosis. Various parameters are introduced into the EM impedance formulation to model the effect of shear-lag phenomenon, sensor breakage, sensor debonding, and structural damage. Finally, the proposed impedance model is used to analytically estimate the change in EM impedance responses induced by the structural damage and the sensor defect. The analytical results are found to be consistent with experimental observations, thus evidencing the feasibility of the novel impedance model for sensor diagnosis and structural integrity assessment. The study is expected to provide theoretical and experimental foundations for impedance monitoring practices, using the piezoelectric interface technique, with the existence of sensor faults. MDPI 2020-01-16 /pmc/articles/PMC7014494/ /pubmed/31963252 http://dx.doi.org/10.3390/s20020510 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Huynh, Thanh-Canh Nguyen, The-Duong Ho, Duc-Duy Dang, Ngoc-Loi Kim, Jeong-Tae Sensor Fault Diagnosis for Impedance Monitoring Using a Piezoelectric-Based Smart Interface Technique |
title | Sensor Fault Diagnosis for Impedance Monitoring Using a Piezoelectric-Based Smart Interface Technique |
title_full | Sensor Fault Diagnosis for Impedance Monitoring Using a Piezoelectric-Based Smart Interface Technique |
title_fullStr | Sensor Fault Diagnosis for Impedance Monitoring Using a Piezoelectric-Based Smart Interface Technique |
title_full_unstemmed | Sensor Fault Diagnosis for Impedance Monitoring Using a Piezoelectric-Based Smart Interface Technique |
title_short | Sensor Fault Diagnosis for Impedance Monitoring Using a Piezoelectric-Based Smart Interface Technique |
title_sort | sensor fault diagnosis for impedance monitoring using a piezoelectric-based smart interface technique |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7014494/ https://www.ncbi.nlm.nih.gov/pubmed/31963252 http://dx.doi.org/10.3390/s20020510 |
work_keys_str_mv | AT huynhthanhcanh sensorfaultdiagnosisforimpedancemonitoringusingapiezoelectricbasedsmartinterfacetechnique AT nguyentheduong sensorfaultdiagnosisforimpedancemonitoringusingapiezoelectricbasedsmartinterfacetechnique AT hoducduy sensorfaultdiagnosisforimpedancemonitoringusingapiezoelectricbasedsmartinterfacetechnique AT dangngocloi sensorfaultdiagnosisforimpedancemonitoringusingapiezoelectricbasedsmartinterfacetechnique AT kimjeongtae sensorfaultdiagnosisforimpedancemonitoringusingapiezoelectricbasedsmartinterfacetechnique |