Cargando…

A rare complication of ipsilateral femoral neck fracture after removal of the long Gamma nail in a healed intertrochanteric fracture

Ipsilateral femoral neck fracture after hardware removal in healed trochanteric fracture is a rare complication. We reported a case of a 79-year-old woman who had undergone open reduction and internal fixation for her left intertrochanteric fracture with a long Gamma nail about 1 year ago. She asked...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Chin-Kai, Hong, Chih-Kai, Su, Wei-Ren, Huang, Yi-Hung, Chao, Lin-Yu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7015005/
https://www.ncbi.nlm.nih.gov/pubmed/32110527
http://dx.doi.org/10.4103/tcmj.tcmj_188_18
_version_ 1783496748569722880
author Huang, Chin-Kai
Hong, Chih-Kai
Su, Wei-Ren
Huang, Yi-Hung
Chao, Lin-Yu
author_facet Huang, Chin-Kai
Hong, Chih-Kai
Su, Wei-Ren
Huang, Yi-Hung
Chao, Lin-Yu
author_sort Huang, Chin-Kai
collection PubMed
description Ipsilateral femoral neck fracture after hardware removal in healed trochanteric fracture is a rare complication. We reported a case of a 79-year-old woman who had undergone open reduction and internal fixation for her left intertrochanteric fracture with a long Gamma nail about 1 year ago. She asked for implants removal due to local irritation. However, 5 days after implants removal, left subcapital femoral neck fracture occurred. Removal of implants under elective indications could lead to high complication rate. Orthopedic surgeons should perform the removal of hardware in healed intertrochanteric fracture for very selected cases.
format Online
Article
Text
id pubmed-7015005
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-70150052020-02-27 A rare complication of ipsilateral femoral neck fracture after removal of the long Gamma nail in a healed intertrochanteric fracture Huang, Chin-Kai Hong, Chih-Kai Su, Wei-Ren Huang, Yi-Hung Chao, Lin-Yu Tzu Chi Med J Case Report Ipsilateral femoral neck fracture after hardware removal in healed trochanteric fracture is a rare complication. We reported a case of a 79-year-old woman who had undergone open reduction and internal fixation for her left intertrochanteric fracture with a long Gamma nail about 1 year ago. She asked for implants removal due to local irritation. However, 5 days after implants removal, left subcapital femoral neck fracture occurred. Removal of implants under elective indications could lead to high complication rate. Orthopedic surgeons should perform the removal of hardware in healed intertrochanteric fracture for very selected cases. Wolters Kluwer - Medknow 2019-01-15 /pmc/articles/PMC7015005/ /pubmed/32110527 http://dx.doi.org/10.4103/tcmj.tcmj_188_18 Text en Copyright: © 2019 Tzu Chi Medical Journal http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Case Report
Huang, Chin-Kai
Hong, Chih-Kai
Su, Wei-Ren
Huang, Yi-Hung
Chao, Lin-Yu
A rare complication of ipsilateral femoral neck fracture after removal of the long Gamma nail in a healed intertrochanteric fracture
title A rare complication of ipsilateral femoral neck fracture after removal of the long Gamma nail in a healed intertrochanteric fracture
title_full A rare complication of ipsilateral femoral neck fracture after removal of the long Gamma nail in a healed intertrochanteric fracture
title_fullStr A rare complication of ipsilateral femoral neck fracture after removal of the long Gamma nail in a healed intertrochanteric fracture
title_full_unstemmed A rare complication of ipsilateral femoral neck fracture after removal of the long Gamma nail in a healed intertrochanteric fracture
title_short A rare complication of ipsilateral femoral neck fracture after removal of the long Gamma nail in a healed intertrochanteric fracture
title_sort rare complication of ipsilateral femoral neck fracture after removal of the long gamma nail in a healed intertrochanteric fracture
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7015005/
https://www.ncbi.nlm.nih.gov/pubmed/32110527
http://dx.doi.org/10.4103/tcmj.tcmj_188_18
work_keys_str_mv AT huangchinkai ararecomplicationofipsilateralfemoralneckfractureafterremovalofthelonggammanailinahealedintertrochantericfracture
AT hongchihkai ararecomplicationofipsilateralfemoralneckfractureafterremovalofthelonggammanailinahealedintertrochantericfracture
AT suweiren ararecomplicationofipsilateralfemoralneckfractureafterremovalofthelonggammanailinahealedintertrochantericfracture
AT huangyihung ararecomplicationofipsilateralfemoralneckfractureafterremovalofthelonggammanailinahealedintertrochantericfracture
AT chaolinyu ararecomplicationofipsilateralfemoralneckfractureafterremovalofthelonggammanailinahealedintertrochantericfracture
AT huangchinkai rarecomplicationofipsilateralfemoralneckfractureafterremovalofthelonggammanailinahealedintertrochantericfracture
AT hongchihkai rarecomplicationofipsilateralfemoralneckfractureafterremovalofthelonggammanailinahealedintertrochantericfracture
AT suweiren rarecomplicationofipsilateralfemoralneckfractureafterremovalofthelonggammanailinahealedintertrochantericfracture
AT huangyihung rarecomplicationofipsilateralfemoralneckfractureafterremovalofthelonggammanailinahealedintertrochantericfracture
AT chaolinyu rarecomplicationofipsilateralfemoralneckfractureafterremovalofthelonggammanailinahealedintertrochantericfracture