Simple Muscle Architecture Analysis (SMA): An ImageJ macro tool to automate measurements in B-mode ultrasound scans

In vivo measurements of muscle architecture (i.e. the spatial arrangement of muscle fascicles) are routinely included in research and clinical settings to monitor muscle structure, function and plasticity. However, in most cases such measurements are performed manually, and more reliable and time-ef...

Descripción completa

Detalles Bibliográficos
Autores principales: Seynnes, Olivier R., Cronin, Neil J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7015391/
https://www.ncbi.nlm.nih.gov/pubmed/32049973
http://dx.doi.org/10.1371/journal.pone.0229034
_version_ 1783496787848331264
author Seynnes, Olivier R.
Cronin, Neil J.
author_facet Seynnes, Olivier R.
Cronin, Neil J.
author_sort Seynnes, Olivier R.
collection PubMed
description In vivo measurements of muscle architecture (i.e. the spatial arrangement of muscle fascicles) are routinely included in research and clinical settings to monitor muscle structure, function and plasticity. However, in most cases such measurements are performed manually, and more reliable and time-efficient automated methods are either lacking completely, or are inaccessible to those without expertise in image analysis. In this work, we propose an ImageJ script to automate the entire analysis process of muscle architecture in ultrasound images: Simple Muscle Architecture Analysis (SMA). Images are filtered in the spatial and frequency domains with built-in commands and external plugins to highlight aponeuroses and fascicles. Fascicle dominant orientation is then computed in regions of interest using the OrientationJ plugin. Bland-Altman plots of analyses performed manually or with SMA indicate that the automated analysis does not induce any systematic bias and that both methods agree equally through the range of measurements. Our test results illustrate the suitability of SMA to analyse images from superficial muscles acquired with a broad range of ultrasound settings.
format Online
Article
Text
id pubmed-7015391
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-70153912020-02-26 Simple Muscle Architecture Analysis (SMA): An ImageJ macro tool to automate measurements in B-mode ultrasound scans Seynnes, Olivier R. Cronin, Neil J. PLoS One Research Article In vivo measurements of muscle architecture (i.e. the spatial arrangement of muscle fascicles) are routinely included in research and clinical settings to monitor muscle structure, function and plasticity. However, in most cases such measurements are performed manually, and more reliable and time-efficient automated methods are either lacking completely, or are inaccessible to those without expertise in image analysis. In this work, we propose an ImageJ script to automate the entire analysis process of muscle architecture in ultrasound images: Simple Muscle Architecture Analysis (SMA). Images are filtered in the spatial and frequency domains with built-in commands and external plugins to highlight aponeuroses and fascicles. Fascicle dominant orientation is then computed in regions of interest using the OrientationJ plugin. Bland-Altman plots of analyses performed manually or with SMA indicate that the automated analysis does not induce any systematic bias and that both methods agree equally through the range of measurements. Our test results illustrate the suitability of SMA to analyse images from superficial muscles acquired with a broad range of ultrasound settings. Public Library of Science 2020-02-12 /pmc/articles/PMC7015391/ /pubmed/32049973 http://dx.doi.org/10.1371/journal.pone.0229034 Text en © 2020 Seynnes, Cronin http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Seynnes, Olivier R.
Cronin, Neil J.
Simple Muscle Architecture Analysis (SMA): An ImageJ macro tool to automate measurements in B-mode ultrasound scans
title Simple Muscle Architecture Analysis (SMA): An ImageJ macro tool to automate measurements in B-mode ultrasound scans
title_full Simple Muscle Architecture Analysis (SMA): An ImageJ macro tool to automate measurements in B-mode ultrasound scans
title_fullStr Simple Muscle Architecture Analysis (SMA): An ImageJ macro tool to automate measurements in B-mode ultrasound scans
title_full_unstemmed Simple Muscle Architecture Analysis (SMA): An ImageJ macro tool to automate measurements in B-mode ultrasound scans
title_short Simple Muscle Architecture Analysis (SMA): An ImageJ macro tool to automate measurements in B-mode ultrasound scans
title_sort simple muscle architecture analysis (sma): an imagej macro tool to automate measurements in b-mode ultrasound scans
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7015391/
https://www.ncbi.nlm.nih.gov/pubmed/32049973
http://dx.doi.org/10.1371/journal.pone.0229034
work_keys_str_mv AT seynnesolivierr simplemusclearchitectureanalysissmaanimagejmacrotooltoautomatemeasurementsinbmodeultrasoundscans
AT croninneilj simplemusclearchitectureanalysissmaanimagejmacrotooltoautomatemeasurementsinbmodeultrasoundscans