Cargando…
Simple Muscle Architecture Analysis (SMA): An ImageJ macro tool to automate measurements in B-mode ultrasound scans
In vivo measurements of muscle architecture (i.e. the spatial arrangement of muscle fascicles) are routinely included in research and clinical settings to monitor muscle structure, function and plasticity. However, in most cases such measurements are performed manually, and more reliable and time-ef...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7015391/ https://www.ncbi.nlm.nih.gov/pubmed/32049973 http://dx.doi.org/10.1371/journal.pone.0229034 |
_version_ | 1783496787848331264 |
---|---|
author | Seynnes, Olivier R. Cronin, Neil J. |
author_facet | Seynnes, Olivier R. Cronin, Neil J. |
author_sort | Seynnes, Olivier R. |
collection | PubMed |
description | In vivo measurements of muscle architecture (i.e. the spatial arrangement of muscle fascicles) are routinely included in research and clinical settings to monitor muscle structure, function and plasticity. However, in most cases such measurements are performed manually, and more reliable and time-efficient automated methods are either lacking completely, or are inaccessible to those without expertise in image analysis. In this work, we propose an ImageJ script to automate the entire analysis process of muscle architecture in ultrasound images: Simple Muscle Architecture Analysis (SMA). Images are filtered in the spatial and frequency domains with built-in commands and external plugins to highlight aponeuroses and fascicles. Fascicle dominant orientation is then computed in regions of interest using the OrientationJ plugin. Bland-Altman plots of analyses performed manually or with SMA indicate that the automated analysis does not induce any systematic bias and that both methods agree equally through the range of measurements. Our test results illustrate the suitability of SMA to analyse images from superficial muscles acquired with a broad range of ultrasound settings. |
format | Online Article Text |
id | pubmed-7015391 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-70153912020-02-26 Simple Muscle Architecture Analysis (SMA): An ImageJ macro tool to automate measurements in B-mode ultrasound scans Seynnes, Olivier R. Cronin, Neil J. PLoS One Research Article In vivo measurements of muscle architecture (i.e. the spatial arrangement of muscle fascicles) are routinely included in research and clinical settings to monitor muscle structure, function and plasticity. However, in most cases such measurements are performed manually, and more reliable and time-efficient automated methods are either lacking completely, or are inaccessible to those without expertise in image analysis. In this work, we propose an ImageJ script to automate the entire analysis process of muscle architecture in ultrasound images: Simple Muscle Architecture Analysis (SMA). Images are filtered in the spatial and frequency domains with built-in commands and external plugins to highlight aponeuroses and fascicles. Fascicle dominant orientation is then computed in regions of interest using the OrientationJ plugin. Bland-Altman plots of analyses performed manually or with SMA indicate that the automated analysis does not induce any systematic bias and that both methods agree equally through the range of measurements. Our test results illustrate the suitability of SMA to analyse images from superficial muscles acquired with a broad range of ultrasound settings. Public Library of Science 2020-02-12 /pmc/articles/PMC7015391/ /pubmed/32049973 http://dx.doi.org/10.1371/journal.pone.0229034 Text en © 2020 Seynnes, Cronin http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Seynnes, Olivier R. Cronin, Neil J. Simple Muscle Architecture Analysis (SMA): An ImageJ macro tool to automate measurements in B-mode ultrasound scans |
title | Simple Muscle Architecture Analysis (SMA): An ImageJ macro tool to automate measurements in B-mode ultrasound scans |
title_full | Simple Muscle Architecture Analysis (SMA): An ImageJ macro tool to automate measurements in B-mode ultrasound scans |
title_fullStr | Simple Muscle Architecture Analysis (SMA): An ImageJ macro tool to automate measurements in B-mode ultrasound scans |
title_full_unstemmed | Simple Muscle Architecture Analysis (SMA): An ImageJ macro tool to automate measurements in B-mode ultrasound scans |
title_short | Simple Muscle Architecture Analysis (SMA): An ImageJ macro tool to automate measurements in B-mode ultrasound scans |
title_sort | simple muscle architecture analysis (sma): an imagej macro tool to automate measurements in b-mode ultrasound scans |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7015391/ https://www.ncbi.nlm.nih.gov/pubmed/32049973 http://dx.doi.org/10.1371/journal.pone.0229034 |
work_keys_str_mv | AT seynnesolivierr simplemusclearchitectureanalysissmaanimagejmacrotooltoautomatemeasurementsinbmodeultrasoundscans AT croninneilj simplemusclearchitectureanalysissmaanimagejmacrotooltoautomatemeasurementsinbmodeultrasoundscans |