Cargando…

Transarterial Onyx embolization with targeted balloon-assisted sinus protection for treatment of dural arteriovenous fistula of the lateral tentorial sinus

We present a unique sinus protection technique that uses a short-length supercompliant balloon during the transarterial Onyx embolization for the dural arteriovenous fistula (DAVF) of the lateral tentorial sinus. With this technique, we temporarily change the Borden classification from type II to ty...

Descripción completa

Detalles Bibliográficos
Autores principales: Matsuo, Kazuya, Fujita, Atsushi, Kohta, Masaaki, Kohmura, Eiji
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7015838/
https://www.ncbi.nlm.nih.gov/pubmed/32071660
http://dx.doi.org/10.1016/j.radcr.2020.01.018
_version_ 1783496863500992512
author Matsuo, Kazuya
Fujita, Atsushi
Kohta, Masaaki
Kohmura, Eiji
author_facet Matsuo, Kazuya
Fujita, Atsushi
Kohta, Masaaki
Kohmura, Eiji
author_sort Matsuo, Kazuya
collection PubMed
description We present a unique sinus protection technique that uses a short-length supercompliant balloon during the transarterial Onyx embolization for the dural arteriovenous fistula (DAVF) of the lateral tentorial sinus. With this technique, we temporarily change the Borden classification from type II to type III, avoiding venous compromise and reducing the risk of Onyx migration into the patent sinus. A 54-year-old man presented with left persistent tinnitus of 4 months’ duration. Cerebral angiography revealed a Borden type II left lateral tentorial sinus-DAVF associated with retrograde cortical venous reflux draining into the vein of Labbé. In the venous phase, the ipsilateral transverse-sigmoid sinus was recognized as a functional sinus and the posterior temporal vein drained into the transverse sinus near the drainage channel. We planned to perform transarterial Onyx embolization using a short-length sinus protection balloon to protect against Onyx migration. During transarterial Onyx injection, a 7 × 7-mm HyperForm balloon was navigated into the affected sinus and positioned to cover the drainage channel from the shunt. After confirming the change in Borden classification with angiography, transarterial Onyx embolization was performed via the middle meningeal artery. This procedure resulted in complete obliteration of the fistula with good patency of both the transverse-sigmoid sinus and neighboring normal cortical veins. No procedure-related complications were observed and the patient remained free of recurrence during the 24-month follow-up period. Short-length balloon-protected Onyx embolization can be safe and effective for the treatment of Borden type II DAVF.
format Online
Article
Text
id pubmed-7015838
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-70158382020-02-18 Transarterial Onyx embolization with targeted balloon-assisted sinus protection for treatment of dural arteriovenous fistula of the lateral tentorial sinus Matsuo, Kazuya Fujita, Atsushi Kohta, Masaaki Kohmura, Eiji Radiol Case Rep Interventional Radiology We present a unique sinus protection technique that uses a short-length supercompliant balloon during the transarterial Onyx embolization for the dural arteriovenous fistula (DAVF) of the lateral tentorial sinus. With this technique, we temporarily change the Borden classification from type II to type III, avoiding venous compromise and reducing the risk of Onyx migration into the patent sinus. A 54-year-old man presented with left persistent tinnitus of 4 months’ duration. Cerebral angiography revealed a Borden type II left lateral tentorial sinus-DAVF associated with retrograde cortical venous reflux draining into the vein of Labbé. In the venous phase, the ipsilateral transverse-sigmoid sinus was recognized as a functional sinus and the posterior temporal vein drained into the transverse sinus near the drainage channel. We planned to perform transarterial Onyx embolization using a short-length sinus protection balloon to protect against Onyx migration. During transarterial Onyx injection, a 7 × 7-mm HyperForm balloon was navigated into the affected sinus and positioned to cover the drainage channel from the shunt. After confirming the change in Borden classification with angiography, transarterial Onyx embolization was performed via the middle meningeal artery. This procedure resulted in complete obliteration of the fistula with good patency of both the transverse-sigmoid sinus and neighboring normal cortical veins. No procedure-related complications were observed and the patient remained free of recurrence during the 24-month follow-up period. Short-length balloon-protected Onyx embolization can be safe and effective for the treatment of Borden type II DAVF. Elsevier 2020-02-07 /pmc/articles/PMC7015838/ /pubmed/32071660 http://dx.doi.org/10.1016/j.radcr.2020.01.018 Text en © 2020 The Authors. Published by Elsevier Inc. on behalf of University of Washington. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Interventional Radiology
Matsuo, Kazuya
Fujita, Atsushi
Kohta, Masaaki
Kohmura, Eiji
Transarterial Onyx embolization with targeted balloon-assisted sinus protection for treatment of dural arteriovenous fistula of the lateral tentorial sinus
title Transarterial Onyx embolization with targeted balloon-assisted sinus protection for treatment of dural arteriovenous fistula of the lateral tentorial sinus
title_full Transarterial Onyx embolization with targeted balloon-assisted sinus protection for treatment of dural arteriovenous fistula of the lateral tentorial sinus
title_fullStr Transarterial Onyx embolization with targeted balloon-assisted sinus protection for treatment of dural arteriovenous fistula of the lateral tentorial sinus
title_full_unstemmed Transarterial Onyx embolization with targeted balloon-assisted sinus protection for treatment of dural arteriovenous fistula of the lateral tentorial sinus
title_short Transarterial Onyx embolization with targeted balloon-assisted sinus protection for treatment of dural arteriovenous fistula of the lateral tentorial sinus
title_sort transarterial onyx embolization with targeted balloon-assisted sinus protection for treatment of dural arteriovenous fistula of the lateral tentorial sinus
topic Interventional Radiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7015838/
https://www.ncbi.nlm.nih.gov/pubmed/32071660
http://dx.doi.org/10.1016/j.radcr.2020.01.018
work_keys_str_mv AT matsuokazuya transarterialonyxembolizationwithtargetedballoonassistedsinusprotectionfortreatmentofduralarteriovenousfistulaofthelateraltentorialsinus
AT fujitaatsushi transarterialonyxembolizationwithtargetedballoonassistedsinusprotectionfortreatmentofduralarteriovenousfistulaofthelateraltentorialsinus
AT kohtamasaaki transarterialonyxembolizationwithtargetedballoonassistedsinusprotectionfortreatmentofduralarteriovenousfistulaofthelateraltentorialsinus
AT kohmuraeiji transarterialonyxembolizationwithtargetedballoonassistedsinusprotectionfortreatmentofduralarteriovenousfistulaofthelateraltentorialsinus