Cargando…

Measurement of apparent diffusion coefficient in discrimination of benign and malignant axillary lymph nodes

PURPOSE: We aimed to determine the contribution of the apparent diffusion coefficient (ADC) value in the detection of axillary lymph node metastasis. MATERIAL AND METHODS: Breast magnetic resonance of 58 patients, performed in the radiology clinic of our hospital between 2015 and 2017 were examined...

Descripción completa

Detalles Bibliográficos
Autores principales: Yılmaz, Ebru, Erok, Berrin, Atca, Ali Önder
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7016376/
https://www.ncbi.nlm.nih.gov/pubmed/32082458
http://dx.doi.org/10.5114/pjr.2019.92315
_version_ 1783496974982447104
author Yılmaz, Ebru
Erok, Berrin
Atca, Ali Önder
author_facet Yılmaz, Ebru
Erok, Berrin
Atca, Ali Önder
author_sort Yılmaz, Ebru
collection PubMed
description PURPOSE: We aimed to determine the contribution of the apparent diffusion coefficient (ADC) value in the detection of axillary lymph node metastasis. MATERIAL AND METHODS: Breast magnetic resonance of 58 patients, performed in the radiology clinic of our hospital between 2015 and 2017 were examined retrospectively, and 43 lymph nodes in 43 patients were included in the study. They were evaluated morphologically on T1W and T2W sequences, and the lymph nodes showing rounded shape, focal or diffuse cortical thickness of more than 3 mm, and partial or total effacement of fatty hilum were included in the study. Subsequently, their ADC values were measured. RESULTS: There were 43 lymph nodes, 20 of which were malignant and 23 of which were benign. While the mean ADC value of malignant axillary lymph nodes was 0.749 10(–3) mm(2)/s (0.48-1.342), it was 0.982 10(–3) mm(2)/s (0.552-1.986) for benign lymph nodes. When the ADC cut-off value was taken as ≤ 0.753 × 10(–3) mm(2)/s, its discrimination power between benign and malignant axillary lymph nodes was as follows: sensitivity – 60%; specificity – 91.3%; accuracy – 76.7%; positive predictive value – 85.7%; and negative predictive value – 72.4%. CONCLUSIONS: There was no significant difference between mean ADC value of 12 lymphadenopathies (LAP) associated with inflammatory breast diseases (granulomatous mastitis and acute suppurative mastitis) and mean ADC value of metastatic lymph nodes. However, the ADC value of lymph nodes showing thickened cortex due to systemic inflammatory diseases was over 1, and there was a statistically significant difference when compared with metastatic lymph nodes.
format Online
Article
Text
id pubmed-7016376
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Termedia Publishing House
record_format MEDLINE/PubMed
spelling pubmed-70163762020-02-20 Measurement of apparent diffusion coefficient in discrimination of benign and malignant axillary lymph nodes Yılmaz, Ebru Erok, Berrin Atca, Ali Önder Pol J Radiol Original Paper PURPOSE: We aimed to determine the contribution of the apparent diffusion coefficient (ADC) value in the detection of axillary lymph node metastasis. MATERIAL AND METHODS: Breast magnetic resonance of 58 patients, performed in the radiology clinic of our hospital between 2015 and 2017 were examined retrospectively, and 43 lymph nodes in 43 patients were included in the study. They were evaluated morphologically on T1W and T2W sequences, and the lymph nodes showing rounded shape, focal or diffuse cortical thickness of more than 3 mm, and partial or total effacement of fatty hilum were included in the study. Subsequently, their ADC values were measured. RESULTS: There were 43 lymph nodes, 20 of which were malignant and 23 of which were benign. While the mean ADC value of malignant axillary lymph nodes was 0.749 10(–3) mm(2)/s (0.48-1.342), it was 0.982 10(–3) mm(2)/s (0.552-1.986) for benign lymph nodes. When the ADC cut-off value was taken as ≤ 0.753 × 10(–3) mm(2)/s, its discrimination power between benign and malignant axillary lymph nodes was as follows: sensitivity – 60%; specificity – 91.3%; accuracy – 76.7%; positive predictive value – 85.7%; and negative predictive value – 72.4%. CONCLUSIONS: There was no significant difference between mean ADC value of 12 lymphadenopathies (LAP) associated with inflammatory breast diseases (granulomatous mastitis and acute suppurative mastitis) and mean ADC value of metastatic lymph nodes. However, the ADC value of lymph nodes showing thickened cortex due to systemic inflammatory diseases was over 1, and there was a statistically significant difference when compared with metastatic lymph nodes. Termedia Publishing House 2019-12-22 /pmc/articles/PMC7016376/ /pubmed/32082458 http://dx.doi.org/10.5114/pjr.2019.92315 Text en Copyright © Polish Medical Society of Radiology 2019 https://creativecommons.org/licenses/by-nc-nd/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial-No Derivatives 4.0 International (CC BY-NC-ND 4.0). License allowing third parties to download articles and share them with others as long as they credit the authors and the publisher, but without permission to change them in any way or use them commercially.
spellingShingle Original Paper
Yılmaz, Ebru
Erok, Berrin
Atca, Ali Önder
Measurement of apparent diffusion coefficient in discrimination of benign and malignant axillary lymph nodes
title Measurement of apparent diffusion coefficient in discrimination of benign and malignant axillary lymph nodes
title_full Measurement of apparent diffusion coefficient in discrimination of benign and malignant axillary lymph nodes
title_fullStr Measurement of apparent diffusion coefficient in discrimination of benign and malignant axillary lymph nodes
title_full_unstemmed Measurement of apparent diffusion coefficient in discrimination of benign and malignant axillary lymph nodes
title_short Measurement of apparent diffusion coefficient in discrimination of benign and malignant axillary lymph nodes
title_sort measurement of apparent diffusion coefficient in discrimination of benign and malignant axillary lymph nodes
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7016376/
https://www.ncbi.nlm.nih.gov/pubmed/32082458
http://dx.doi.org/10.5114/pjr.2019.92315
work_keys_str_mv AT yılmazebru measurementofapparentdiffusioncoefficientindiscriminationofbenignandmalignantaxillarylymphnodes
AT erokberrin measurementofapparentdiffusioncoefficientindiscriminationofbenignandmalignantaxillarylymphnodes
AT atcaalionder measurementofapparentdiffusioncoefficientindiscriminationofbenignandmalignantaxillarylymphnodes