Cargando…
Detecting Escherichia coli Biofilm Development Stages on Gold and Titanium by Quartz Crystal Microbalance
[Image: see text] Bacterial biofilms are responsible for persistent infections and biofouling, raising serious concerns in both medical and industrial processes. These motivations underpin the need to develop methodologies to study the complex biological structures of biofilms and prevent their form...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Chemical Society
2020
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7017401/ https://www.ncbi.nlm.nih.gov/pubmed/32064391 http://dx.doi.org/10.1021/acsomega.9b03540 |
_version_ | 1783497188707401728 |
---|---|
author | Ripa, Rosa Shen, Amy Q. Funari, Riccardo |
author_facet | Ripa, Rosa Shen, Amy Q. Funari, Riccardo |
author_sort | Ripa, Rosa |
collection | PubMed |
description | [Image: see text] Bacterial biofilms are responsible for persistent infections and biofouling, raising serious concerns in both medical and industrial processes. These motivations underpin the need to develop methodologies to study the complex biological structures of biofilms and prevent their formation on medical implants, tools, and industrial apparatuses. Here, we report the detailed comparison of Escherichia coli biofilm development stages (adhesion, maturation, and dispersion) on gold and titanium surfaces by monitoring the changes in both frequency and dissipation of a quartz crystal microbalance (QCM) device, a cheap and reliable microgravimetric sensor which allows the real-time and label-free characterization of various stages of biofilm development. Although gold is the most common electrode material used for QCM sensors, the titanium electrode is also readily available for QCM sensors; thus, QCM sensors with different metal electrodes serve as a simple platform to probe how pathogens interact with different metal substrates. The QCM outcomes are further confirmed by atomic force microscopy and crystal violet staining, thus validating the effectiveness of this surface sensitive sensor for microbial biofilm research. Moreover, because QCM technology can easily modify the substrate types and coatings, QCM sensors also provide well-controlled experimental conditions to study antimicrobial surface treatments and eradication procedures, even on mature biofilms. |
format | Online Article Text |
id | pubmed-7017401 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | American Chemical Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-70174012020-02-14 Detecting Escherichia coli Biofilm Development Stages on Gold and Titanium by Quartz Crystal Microbalance Ripa, Rosa Shen, Amy Q. Funari, Riccardo ACS Omega [Image: see text] Bacterial biofilms are responsible for persistent infections and biofouling, raising serious concerns in both medical and industrial processes. These motivations underpin the need to develop methodologies to study the complex biological structures of biofilms and prevent their formation on medical implants, tools, and industrial apparatuses. Here, we report the detailed comparison of Escherichia coli biofilm development stages (adhesion, maturation, and dispersion) on gold and titanium surfaces by monitoring the changes in both frequency and dissipation of a quartz crystal microbalance (QCM) device, a cheap and reliable microgravimetric sensor which allows the real-time and label-free characterization of various stages of biofilm development. Although gold is the most common electrode material used for QCM sensors, the titanium electrode is also readily available for QCM sensors; thus, QCM sensors with different metal electrodes serve as a simple platform to probe how pathogens interact with different metal substrates. The QCM outcomes are further confirmed by atomic force microscopy and crystal violet staining, thus validating the effectiveness of this surface sensitive sensor for microbial biofilm research. Moreover, because QCM technology can easily modify the substrate types and coatings, QCM sensors also provide well-controlled experimental conditions to study antimicrobial surface treatments and eradication procedures, even on mature biofilms. American Chemical Society 2020-01-28 /pmc/articles/PMC7017401/ /pubmed/32064391 http://dx.doi.org/10.1021/acsomega.9b03540 Text en Copyright © 2020 American Chemical Society This is an open access article published under an ACS AuthorChoice License (http://pubs.acs.org/page/policy/authorchoice_termsofuse.html) , which permits copying and redistribution of the article or any adaptations for non-commercial purposes. |
spellingShingle | Ripa, Rosa Shen, Amy Q. Funari, Riccardo Detecting Escherichia coli Biofilm Development Stages on Gold and Titanium by Quartz Crystal Microbalance |
title | Detecting Escherichia coli Biofilm
Development Stages on Gold and Titanium by Quartz Crystal
Microbalance |
title_full | Detecting Escherichia coli Biofilm
Development Stages on Gold and Titanium by Quartz Crystal
Microbalance |
title_fullStr | Detecting Escherichia coli Biofilm
Development Stages on Gold and Titanium by Quartz Crystal
Microbalance |
title_full_unstemmed | Detecting Escherichia coli Biofilm
Development Stages on Gold and Titanium by Quartz Crystal
Microbalance |
title_short | Detecting Escherichia coli Biofilm
Development Stages on Gold and Titanium by Quartz Crystal
Microbalance |
title_sort | detecting escherichia coli biofilm
development stages on gold and titanium by quartz crystal
microbalance |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7017401/ https://www.ncbi.nlm.nih.gov/pubmed/32064391 http://dx.doi.org/10.1021/acsomega.9b03540 |
work_keys_str_mv | AT riparosa detectingescherichiacolibiofilmdevelopmentstagesongoldandtitaniumbyquartzcrystalmicrobalance AT shenamyq detectingescherichiacolibiofilmdevelopmentstagesongoldandtitaniumbyquartzcrystalmicrobalance AT funaririccardo detectingescherichiacolibiofilmdevelopmentstagesongoldandtitaniumbyquartzcrystalmicrobalance |