Correlation between correctly sized uncuffed endotracheal tube and ultrasonographically determined subglottic diameter in paediatric population
BACKGROUND AND AIMS: Conventional age-based formulae often fail to predict correct size of endotracheal tube (ETT). In this study, we evaluated usefulness of ultrasound in determining appropriate tube size and derived a formula which enables us to predict correct tube size. METHODS: A total of 41 Am...
Autores principales: | Makireddy, Rekha, Cherian, Anusha, Elakkumanan, Lenin Babu, Bidkar, Prasanna Udupi, Kundra, Pankaj |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7017658/ https://www.ncbi.nlm.nih.gov/pubmed/32139927 http://dx.doi.org/10.4103/ija.IJA_619_19 |
Ejemplares similares
-
A Modified Insertion Technique of Ambu AuraGain™ Laryngeal Airway, a Third-generation Supraglottic Airway to Reduce the Oral Mucosal Injury
por: Mishra, Sandeep Kumar, et al.
Publicado: (2017) -
Prediction of endotracheal tube size in children by predicting subglottic diameter using ultrasonographic measurement versus traditional formulas
por: Singh, Shubhi, et al.
Publicado: (2019) -
Evaluation of simple pre-determined length insertion technique (SPLIT) with conventional method for oral fibreoptic intubation: A randomised cross-over study
por: Muthukumar, Elangovan, et al.
Publicado: (2017) -
Prediction of Endotracheal Tube Size in Pediatric Population Using Ultrasonographic Subglottic Diameter and Age-Related Formulas: A Comparative Study
por: Bharathi, B. M., et al.
Publicado: (2022) -
Comparison of different regimens of intravenous dexmedetomidine on duration of subarachnoid block
por: Thomas, Anil, et al.
Publicado: (2016)