Accuracy of Computer-Aided Dynamic Navigation Compared to Computer-Aided Static Procedure for Endodontic Access Cavities: An In Vitro Study
Purpose: To analyze the accuracy of two computer-aided navigation techniques to guide the performance of endodontic access cavities compared with the conventional access procedure. Materials and Methods: A total of 30 single-rooted anterior teeth were selected, which were randomly distributed into t...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7019931/ https://www.ncbi.nlm.nih.gov/pubmed/31906598 http://dx.doi.org/10.3390/jcm9010129 |
Sumario: | Purpose: To analyze the accuracy of two computer-aided navigation techniques to guide the performance of endodontic access cavities compared with the conventional access procedure. Materials and Methods: A total of 30 single-rooted anterior teeth were selected, which were randomly distributed into three study groups: Group A—guided performance of endodontic access cavities through computer-aided static navigation system (n = 10) (SN); Group B—guided performance of endodontic access cavities through computer-aided dynamic navigation system (n = 10) (DN); and Group C—manual (freehand) performance of endodontic access cavities (n = 10) (MN). The endodontic access cavities of the SN group were performed with a stereolithography template designed on 3D implant planning software, based on preoperative cone-beam computed tomography (CBCT) and a 3D extraoral surface scan, and endodontic access cavities of the DN group were planned and performed by the dynamic navigation system. After endodontic access cavities were performed, a second CBCT was done, and the degree of accuracy between the planned and performed endodontic access cavities was analyzed using therapeutic planning software and Student’s t-test. Results: Paired t-test revealed no statistically significant differences between SN and DN at the coronal (p = 0.6542), apical (p = 0.9144), or angular (p = 0.0724) level; however, statistically significant differences were observed between the two computer-aided navigation techniques and the MN group at the coronal (p < 0.0001), apical (p < 0.0001), and angular (p < 0.0001) level. Conclusion: Both computer-aided static and dynamic navigation procedures allowed accurate performance of endodontic access cavities. |
---|