Cargando…
Impact of One-Catheter Strategy with TIG I Catheter on Coronary Catheterization Performance and Economic Costs
BACKGROUND: Coronary angiography with two catheters is the traditional strategy for diagnostic coronary procedures. TIG I catheter permits to cannulate both coronary arteries, avoiding exchanging catheters during coronary angiography by transradial access. OBJECTIVE: The aim of this study is to eval...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Sociedade Brasileira de Cardiologia - SBC
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7020970/ https://www.ncbi.nlm.nih.gov/pubmed/31800721 http://dx.doi.org/10.5935/abc.20190232 |
_version_ | 1783497846079619072 |
---|---|
author | Costa-Mateu, Joan Fernández-Rodríguez, Diego Rivera, Kristian Casanova, Juan Irigaray, Patricia Zielonka, Marta Pereyra-Acha, Eduardo Aldomá, Albina Worner, Fernando |
author_facet | Costa-Mateu, Joan Fernández-Rodríguez, Diego Rivera, Kristian Casanova, Juan Irigaray, Patricia Zielonka, Marta Pereyra-Acha, Eduardo Aldomá, Albina Worner, Fernando |
author_sort | Costa-Mateu, Joan |
collection | PubMed |
description | BACKGROUND: Coronary angiography with two catheters is the traditional strategy for diagnostic coronary procedures. TIG I catheter permits to cannulate both coronary arteries, avoiding exchanging catheters during coronary angiography by transradial access. OBJECTIVE: The aim of this study is to evaluate the impact of one-catheter strategy, by avoiding catheter exchange, on coronary catheterization performance and economic costs. METHODS: Transradial coronary diagnostic procedures conducted from January 2013 to June 2017 were collected. One-catheter strategy (TIG I catheter) and two-catheter strategy (left and right Judkins catheters) were compared. The volume of iodinated contrast administered was the primary endpoint. Secondary endpoints included radial spasm, procedural duration (fluoroscopy time) and exposure to ionizing radiation (dose-area product and air kerma). Direct economic costs were also evaluated. For statistical analyses, two-tailed p-values < 0.05 were considered statistically significant. RESULTS: From a total of 1,953 procedures in 1,829 patients, 252 procedures were assigned to one-catheter strategy and 1,701 procedures to two-catheter strategy. There were no differences in baseline characteristics between the groups. One-catheter strategy required less iodinated contrast [primary endpoint; (60-105)-mL vs. 92 (64-120)-mL; p < 0.001] than the two-catheter strategy. Also, the one-catheter group presented less radial spasm (5.2% vs. 9.3%, p = 0.022) and shorter fluoroscopy time [3.9 (2.2-8.0)-min vs. 4.8 (2.9-8.3)-min, p = 0.001] and saved costs [149 (140-160)-€/procedure vs. 171 (160-183)-€/procedure; p < 0.001]. No differences in dose-area product and air kerma were detected between the groups. CONCLUSIONS: One-catheter strategy, with TIG I catheter, improves coronary catheterization performance and reduces economic costs compared to traditional two-catheter strategy in patients referred for coronary angiography. |
format | Online Article Text |
id | pubmed-7020970 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Sociedade Brasileira de Cardiologia - SBC |
record_format | MEDLINE/PubMed |
spelling | pubmed-70209702020-02-20 Impact of One-Catheter Strategy with TIG I Catheter on Coronary Catheterization Performance and Economic Costs Costa-Mateu, Joan Fernández-Rodríguez, Diego Rivera, Kristian Casanova, Juan Irigaray, Patricia Zielonka, Marta Pereyra-Acha, Eduardo Aldomá, Albina Worner, Fernando Arq Bras Cardiol Original Article BACKGROUND: Coronary angiography with two catheters is the traditional strategy for diagnostic coronary procedures. TIG I catheter permits to cannulate both coronary arteries, avoiding exchanging catheters during coronary angiography by transradial access. OBJECTIVE: The aim of this study is to evaluate the impact of one-catheter strategy, by avoiding catheter exchange, on coronary catheterization performance and economic costs. METHODS: Transradial coronary diagnostic procedures conducted from January 2013 to June 2017 were collected. One-catheter strategy (TIG I catheter) and two-catheter strategy (left and right Judkins catheters) were compared. The volume of iodinated contrast administered was the primary endpoint. Secondary endpoints included radial spasm, procedural duration (fluoroscopy time) and exposure to ionizing radiation (dose-area product and air kerma). Direct economic costs were also evaluated. For statistical analyses, two-tailed p-values < 0.05 were considered statistically significant. RESULTS: From a total of 1,953 procedures in 1,829 patients, 252 procedures were assigned to one-catheter strategy and 1,701 procedures to two-catheter strategy. There were no differences in baseline characteristics between the groups. One-catheter strategy required less iodinated contrast [primary endpoint; (60-105)-mL vs. 92 (64-120)-mL; p < 0.001] than the two-catheter strategy. Also, the one-catheter group presented less radial spasm (5.2% vs. 9.3%, p = 0.022) and shorter fluoroscopy time [3.9 (2.2-8.0)-min vs. 4.8 (2.9-8.3)-min, p = 0.001] and saved costs [149 (140-160)-€/procedure vs. 171 (160-183)-€/procedure; p < 0.001]. No differences in dose-area product and air kerma were detected between the groups. CONCLUSIONS: One-catheter strategy, with TIG I catheter, improves coronary catheterization performance and reduces economic costs compared to traditional two-catheter strategy in patients referred for coronary angiography. Sociedade Brasileira de Cardiologia - SBC 2019-11 /pmc/articles/PMC7020970/ /pubmed/31800721 http://dx.doi.org/10.5935/abc.20190232 Text en http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Costa-Mateu, Joan Fernández-Rodríguez, Diego Rivera, Kristian Casanova, Juan Irigaray, Patricia Zielonka, Marta Pereyra-Acha, Eduardo Aldomá, Albina Worner, Fernando Impact of One-Catheter Strategy with TIG I Catheter on Coronary Catheterization Performance and Economic Costs |
title | Impact of One-Catheter Strategy with TIG I Catheter on Coronary Catheterization Performance and Economic Costs |
title_full | Impact of One-Catheter Strategy with TIG I Catheter on Coronary Catheterization Performance and Economic Costs |
title_fullStr | Impact of One-Catheter Strategy with TIG I Catheter on Coronary Catheterization Performance and Economic Costs |
title_full_unstemmed | Impact of One-Catheter Strategy with TIG I Catheter on Coronary Catheterization Performance and Economic Costs |
title_short | Impact of One-Catheter Strategy with TIG I Catheter on Coronary Catheterization Performance and Economic Costs |
title_sort | impact of one-catheter strategy with tig i catheter on coronary catheterization performance and economic costs |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7020970/ https://www.ncbi.nlm.nih.gov/pubmed/31800721 http://dx.doi.org/10.5935/abc.20190232 |
work_keys_str_mv | AT costamateujoan impactofonecatheterstrategywithtigicatheteroncoronarycatheterizationperformanceandeconomiccosts AT fernandezrodriguezdiego impactofonecatheterstrategywithtigicatheteroncoronarycatheterizationperformanceandeconomiccosts AT riverakristian impactofonecatheterstrategywithtigicatheteroncoronarycatheterizationperformanceandeconomiccosts AT casanovajuan impactofonecatheterstrategywithtigicatheteroncoronarycatheterizationperformanceandeconomiccosts AT irigaraypatricia impactofonecatheterstrategywithtigicatheteroncoronarycatheterizationperformanceandeconomiccosts AT zielonkamarta impactofonecatheterstrategywithtigicatheteroncoronarycatheterizationperformanceandeconomiccosts AT pereyraachaeduardo impactofonecatheterstrategywithtigicatheteroncoronarycatheterizationperformanceandeconomiccosts AT aldomaalbina impactofonecatheterstrategywithtigicatheteroncoronarycatheterizationperformanceandeconomiccosts AT wornerfernando impactofonecatheterstrategywithtigicatheteroncoronarycatheterizationperformanceandeconomiccosts |