Comparison of radiation dose and image quality between flat panel computed tomography and multidetector computed tomography in a hybrid CT‐angiography suite

The purpose of this study was to compare, using the same radiation dose and image quality metrics, flat panel computed tomography (FPCT) to multidetector CT (MDCT) in interventional radiology. A single robotic angiography system with FPCT was compared to a single MDCT system, both installed in a hyb...

Descripción completa

Detalles Bibliográficos
Autores principales: Jones, Aaron K., Odisio, Bruno C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7020994/
https://www.ncbi.nlm.nih.gov/pubmed/31922349
http://dx.doi.org/10.1002/acm2.12808
_version_ 1783497849583960064
author Jones, Aaron K.
Odisio, Bruno C.
author_facet Jones, Aaron K.
Odisio, Bruno C.
author_sort Jones, Aaron K.
collection PubMed
description The purpose of this study was to compare, using the same radiation dose and image quality metrics, flat panel computed tomography (FPCT) to multidetector CT (MDCT) in interventional radiology. A single robotic angiography system with FPCT was compared to a single MDCT system, both installed in a hybrid CT‐angiography laboratory and both operating under automatic exposure control. Radiation dose was measured on the central axis (D(c)) of a CT dosimetry phantom 30 cm in diameter and 60 cm in length using default protocols for FPCT and MDCT with the imaged length in MDCT matched to the field of view of FPCT. The noise power spectrum (NPS), modulation transfer function (MTF), and z‐axis resolution were measured using the same phantom. Iodine contrast to noise ratio (CNR) was also measured. Radiation dose (D(c)) was 41%–69% lower in MDCT compared to FPCT when default protocols and automatic exposure control were used. While spatial resolution could generally be matched with appropriate choice of kernel in MDCT, MTF dropped more quickly at higher spatial frequency for MDCT than FPCT. Image noise was 49%–120% higher for MDCT compared to FPCT for comparable in‐plane spatial resolution. Z‐axis resolution was slightly better for MDCT than FPCT, while iodine CNR depended on protocol selection. Radiation dose was much lower for MDCT compared to FPCT, but image noise was much higher. Matching image noise in MDCT to FPCT would result in similar radiation doses. Iodine contrast depended on dose modulation settings for MDCT.
format Online
Article
Text
id pubmed-7020994
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-70209942020-03-06 Comparison of radiation dose and image quality between flat panel computed tomography and multidetector computed tomography in a hybrid CT‐angiography suite Jones, Aaron K. Odisio, Bruno C. J Appl Clin Med Phys Medical Imaging The purpose of this study was to compare, using the same radiation dose and image quality metrics, flat panel computed tomography (FPCT) to multidetector CT (MDCT) in interventional radiology. A single robotic angiography system with FPCT was compared to a single MDCT system, both installed in a hybrid CT‐angiography laboratory and both operating under automatic exposure control. Radiation dose was measured on the central axis (D(c)) of a CT dosimetry phantom 30 cm in diameter and 60 cm in length using default protocols for FPCT and MDCT with the imaged length in MDCT matched to the field of view of FPCT. The noise power spectrum (NPS), modulation transfer function (MTF), and z‐axis resolution were measured using the same phantom. Iodine contrast to noise ratio (CNR) was also measured. Radiation dose (D(c)) was 41%–69% lower in MDCT compared to FPCT when default protocols and automatic exposure control were used. While spatial resolution could generally be matched with appropriate choice of kernel in MDCT, MTF dropped more quickly at higher spatial frequency for MDCT than FPCT. Image noise was 49%–120% higher for MDCT compared to FPCT for comparable in‐plane spatial resolution. Z‐axis resolution was slightly better for MDCT than FPCT, while iodine CNR depended on protocol selection. Radiation dose was much lower for MDCT compared to FPCT, but image noise was much higher. Matching image noise in MDCT to FPCT would result in similar radiation doses. Iodine contrast depended on dose modulation settings for MDCT. John Wiley and Sons Inc. 2020-01-10 /pmc/articles/PMC7020994/ /pubmed/31922349 http://dx.doi.org/10.1002/acm2.12808 Text en © 2020 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Medical Imaging
Jones, Aaron K.
Odisio, Bruno C.
Comparison of radiation dose and image quality between flat panel computed tomography and multidetector computed tomography in a hybrid CT‐angiography suite
title Comparison of radiation dose and image quality between flat panel computed tomography and multidetector computed tomography in a hybrid CT‐angiography suite
title_full Comparison of radiation dose and image quality between flat panel computed tomography and multidetector computed tomography in a hybrid CT‐angiography suite
title_fullStr Comparison of radiation dose and image quality between flat panel computed tomography and multidetector computed tomography in a hybrid CT‐angiography suite
title_full_unstemmed Comparison of radiation dose and image quality between flat panel computed tomography and multidetector computed tomography in a hybrid CT‐angiography suite
title_short Comparison of radiation dose and image quality between flat panel computed tomography and multidetector computed tomography in a hybrid CT‐angiography suite
title_sort comparison of radiation dose and image quality between flat panel computed tomography and multidetector computed tomography in a hybrid ct‐angiography suite
topic Medical Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7020994/
https://www.ncbi.nlm.nih.gov/pubmed/31922349
http://dx.doi.org/10.1002/acm2.12808
work_keys_str_mv AT jonesaaronk comparisonofradiationdoseandimagequalitybetweenflatpanelcomputedtomographyandmultidetectorcomputedtomographyinahybridctangiographysuite
AT odisiobrunoc comparisonofradiationdoseandimagequalitybetweenflatpanelcomputedtomographyandmultidetectorcomputedtomographyinahybridctangiographysuite