Cargando…

Diagnostic criteria for detection of retinal nerve fibre layer thickness and neuroretinal rim width abnormalities in glaucoma

BACKGROUND/AIMS: Although measurements of the Bruch’s membrane opening minimum rim width (BMO-MRW) and retinal nerve fibre layer thickness (RNFLT) with optical coherence tomography (OCT) have been widely adopted in the diagnostic evaluation of glaucoma, there is no consensus on the diagnostic criter...

Descripción completa

Detalles Bibliográficos
Autores principales: Zheng, Feihui, Yu, Marco, Leung, Christopher Kai-Shun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7025733/
https://www.ncbi.nlm.nih.gov/pubmed/31147377
http://dx.doi.org/10.1136/bjophthalmol-2018-313581
_version_ 1783498563712450560
author Zheng, Feihui
Yu, Marco
Leung, Christopher Kai-Shun
author_facet Zheng, Feihui
Yu, Marco
Leung, Christopher Kai-Shun
author_sort Zheng, Feihui
collection PubMed
description BACKGROUND/AIMS: Although measurements of the Bruch’s membrane opening minimum rim width (BMO-MRW) and retinal nerve fibre layer thickness (RNFLT) with optical coherence tomography (OCT) have been widely adopted in the diagnostic evaluation of glaucoma, there is no consensus on the diagnostic criteria to define BMO-MRW and RNFLT abnormalities. This study investigated the sensitivities and specificities of different diagnostic criteria based on the OCT classification reports for detection of glaucoma. METHODS: 340 eyes of 137 patients with glaucoma and 87 healthy individuals, all with axial length ≤26mm, had global and sectoral BMO-MRW and RNFLT measured with Spectralis OCT (Heidelberg Engineering). Six diagnostic criteria were examined: global measurement below the fifth or the first percentile; ≥1 sector measurement below the fifth or the first percentile; superotemporal and/or inferotemporal measurement below the fifth or the first percentile. The sensitivities and specificities of BMO-MRW/RNFLT assessment for detection of glaucoma (eyes with visual field (VF) defects) were compared. RESULTS: Among the six criteria examined, superotemporal and/or inferotemporal measurement below the fifth percentile showed the highest sensitivities and specificities for glaucoma detection. Abnormal superotemporal and/or inferotemporal RNFLT attained a higher sensitivity than abnormal superotemporal and/or inferotemporal BMO-MRW to detect mild glaucoma (mean VF MD: −3.32±1.59 dB) (97.9% and 88.4%, respectively, p=0.006), and glaucoma (mean VF MD: −9.36±8.31 dB) (98.4% and 93.6%, respectively, p=0.006), at the same specificity (96.1%). CONCLUSIONS: Superotemporal and/or inferotemporal RNFLT/MRW below the fifth percentile yield the best diagnostic performance for glaucoma detection with RNFLT attains higher sensitivities than MRW at the same specificity in eyes without high myopia.
format Online
Article
Text
id pubmed-7025733
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-70257332020-02-28 Diagnostic criteria for detection of retinal nerve fibre layer thickness and neuroretinal rim width abnormalities in glaucoma Zheng, Feihui Yu, Marco Leung, Christopher Kai-Shun Br J Ophthalmol Clinical Science BACKGROUND/AIMS: Although measurements of the Bruch’s membrane opening minimum rim width (BMO-MRW) and retinal nerve fibre layer thickness (RNFLT) with optical coherence tomography (OCT) have been widely adopted in the diagnostic evaluation of glaucoma, there is no consensus on the diagnostic criteria to define BMO-MRW and RNFLT abnormalities. This study investigated the sensitivities and specificities of different diagnostic criteria based on the OCT classification reports for detection of glaucoma. METHODS: 340 eyes of 137 patients with glaucoma and 87 healthy individuals, all with axial length ≤26mm, had global and sectoral BMO-MRW and RNFLT measured with Spectralis OCT (Heidelberg Engineering). Six diagnostic criteria were examined: global measurement below the fifth or the first percentile; ≥1 sector measurement below the fifth or the first percentile; superotemporal and/or inferotemporal measurement below the fifth or the first percentile. The sensitivities and specificities of BMO-MRW/RNFLT assessment for detection of glaucoma (eyes with visual field (VF) defects) were compared. RESULTS: Among the six criteria examined, superotemporal and/or inferotemporal measurement below the fifth percentile showed the highest sensitivities and specificities for glaucoma detection. Abnormal superotemporal and/or inferotemporal RNFLT attained a higher sensitivity than abnormal superotemporal and/or inferotemporal BMO-MRW to detect mild glaucoma (mean VF MD: −3.32±1.59 dB) (97.9% and 88.4%, respectively, p=0.006), and glaucoma (mean VF MD: −9.36±8.31 dB) (98.4% and 93.6%, respectively, p=0.006), at the same specificity (96.1%). CONCLUSIONS: Superotemporal and/or inferotemporal RNFLT/MRW below the fifth percentile yield the best diagnostic performance for glaucoma detection with RNFLT attains higher sensitivities than MRW at the same specificity in eyes without high myopia. BMJ Publishing Group 2020-02 2019-05-30 /pmc/articles/PMC7025733/ /pubmed/31147377 http://dx.doi.org/10.1136/bjophthalmol-2018-313581 Text en © Author(s) (or their employer(s)) 2020. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. http://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/.
spellingShingle Clinical Science
Zheng, Feihui
Yu, Marco
Leung, Christopher Kai-Shun
Diagnostic criteria for detection of retinal nerve fibre layer thickness and neuroretinal rim width abnormalities in glaucoma
title Diagnostic criteria for detection of retinal nerve fibre layer thickness and neuroretinal rim width abnormalities in glaucoma
title_full Diagnostic criteria for detection of retinal nerve fibre layer thickness and neuroretinal rim width abnormalities in glaucoma
title_fullStr Diagnostic criteria for detection of retinal nerve fibre layer thickness and neuroretinal rim width abnormalities in glaucoma
title_full_unstemmed Diagnostic criteria for detection of retinal nerve fibre layer thickness and neuroretinal rim width abnormalities in glaucoma
title_short Diagnostic criteria for detection of retinal nerve fibre layer thickness and neuroretinal rim width abnormalities in glaucoma
title_sort diagnostic criteria for detection of retinal nerve fibre layer thickness and neuroretinal rim width abnormalities in glaucoma
topic Clinical Science
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7025733/
https://www.ncbi.nlm.nih.gov/pubmed/31147377
http://dx.doi.org/10.1136/bjophthalmol-2018-313581
work_keys_str_mv AT zhengfeihui diagnosticcriteriafordetectionofretinalnervefibrelayerthicknessandneuroretinalrimwidthabnormalitiesinglaucoma
AT yumarco diagnosticcriteriafordetectionofretinalnervefibrelayerthicknessandneuroretinalrimwidthabnormalitiesinglaucoma
AT leungchristopherkaishun diagnosticcriteriafordetectionofretinalnervefibrelayerthicknessandneuroretinalrimwidthabnormalitiesinglaucoma