Cargando…
Anatomical reduction and precise internal fixation of intra-articular fractures of the distal radius with virtual X-ray and 3D printing
To evaluate and precisely internal fix intra-articular distal radial fracture (IDRF) using the virtual X-ray and three-dimensional (3D) printing technologies. Twenty-one patients with IDRF were recruited, and the data from digital design group (DDG) and real surgery group (RSG) were collected and an...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7026237/ https://www.ncbi.nlm.nih.gov/pubmed/31641940 http://dx.doi.org/10.1007/s13246-019-00795-w |
_version_ | 1783498651757182976 |
---|---|
author | Xu, Jing Zhang, Guodong He, Zaopeng Zhong, Shizhen Chen, Yongshao Wei, Chunrong Zheng, Yudong Lin, Haibin Li, Wei Huang, Wenhua |
author_facet | Xu, Jing Zhang, Guodong He, Zaopeng Zhong, Shizhen Chen, Yongshao Wei, Chunrong Zheng, Yudong Lin, Haibin Li, Wei Huang, Wenhua |
author_sort | Xu, Jing |
collection | PubMed |
description | To evaluate and precisely internal fix intra-articular distal radial fracture (IDRF) using the virtual X-ray and three-dimensional (3D) printing technologies. Twenty-one patients with IDRF were recruited, and the data from digital design group (DDG) and real surgery group (RSG) were collected and analyzed. In DDG, the data from thin-slice computed tomography scan, virtual X-ray measurement parameters, including volar tilt, palmar tilt, radius length (D1), ulnar variation (D2), locking plate position parameter (D3) and distance between key nail and joint surface (D4) were collected. The bone was virtually fixed with the locking plate, and the final model of radius with the screw was obtained by 3D printing. In RSG, the locking plate was precisely pre-bended and used in surgery. During the surgery, the key K-wire was accurately placed and the locking plate was adjusted with the aid of the U-shaped navigation arm. The C-arm was used to observe the positions of key K-wires and the locking plate, and the same above-mentioned parameters were measured intra- and post-operatively. The data from RSG and DDG were compared statistically by t test. This approach proved to be successful in all 21 patients, and none of the screws pierced through the wrist joint surface. All the measured parameters, including the volar tilt, palmar tilt, D1–4, in RSG were not significantly different from preoperative DDG data. Virtual X-ray measurement of anatomical reduction parameters and 3D printing can help the anatomical reduction and precise internal fixation by providing quantitative references, preoperatively, intraoperatively and postoperatively. |
format | Online Article Text |
id | pubmed-7026237 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-70262372020-03-02 Anatomical reduction and precise internal fixation of intra-articular fractures of the distal radius with virtual X-ray and 3D printing Xu, Jing Zhang, Guodong He, Zaopeng Zhong, Shizhen Chen, Yongshao Wei, Chunrong Zheng, Yudong Lin, Haibin Li, Wei Huang, Wenhua Phys Eng Sci Med Scientific Paper To evaluate and precisely internal fix intra-articular distal radial fracture (IDRF) using the virtual X-ray and three-dimensional (3D) printing technologies. Twenty-one patients with IDRF were recruited, and the data from digital design group (DDG) and real surgery group (RSG) were collected and analyzed. In DDG, the data from thin-slice computed tomography scan, virtual X-ray measurement parameters, including volar tilt, palmar tilt, radius length (D1), ulnar variation (D2), locking plate position parameter (D3) and distance between key nail and joint surface (D4) were collected. The bone was virtually fixed with the locking plate, and the final model of radius with the screw was obtained by 3D printing. In RSG, the locking plate was precisely pre-bended and used in surgery. During the surgery, the key K-wire was accurately placed and the locking plate was adjusted with the aid of the U-shaped navigation arm. The C-arm was used to observe the positions of key K-wires and the locking plate, and the same above-mentioned parameters were measured intra- and post-operatively. The data from RSG and DDG were compared statistically by t test. This approach proved to be successful in all 21 patients, and none of the screws pierced through the wrist joint surface. All the measured parameters, including the volar tilt, palmar tilt, D1–4, in RSG were not significantly different from preoperative DDG data. Virtual X-ray measurement of anatomical reduction parameters and 3D printing can help the anatomical reduction and precise internal fixation by providing quantitative references, preoperatively, intraoperatively and postoperatively. Springer International Publishing 2019-10-22 2020 /pmc/articles/PMC7026237/ /pubmed/31641940 http://dx.doi.org/10.1007/s13246-019-00795-w Text en © The Author(s) 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Scientific Paper Xu, Jing Zhang, Guodong He, Zaopeng Zhong, Shizhen Chen, Yongshao Wei, Chunrong Zheng, Yudong Lin, Haibin Li, Wei Huang, Wenhua Anatomical reduction and precise internal fixation of intra-articular fractures of the distal radius with virtual X-ray and 3D printing |
title | Anatomical reduction and precise internal fixation of intra-articular fractures of the distal radius with virtual X-ray and 3D printing |
title_full | Anatomical reduction and precise internal fixation of intra-articular fractures of the distal radius with virtual X-ray and 3D printing |
title_fullStr | Anatomical reduction and precise internal fixation of intra-articular fractures of the distal radius with virtual X-ray and 3D printing |
title_full_unstemmed | Anatomical reduction and precise internal fixation of intra-articular fractures of the distal radius with virtual X-ray and 3D printing |
title_short | Anatomical reduction and precise internal fixation of intra-articular fractures of the distal radius with virtual X-ray and 3D printing |
title_sort | anatomical reduction and precise internal fixation of intra-articular fractures of the distal radius with virtual x-ray and 3d printing |
topic | Scientific Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7026237/ https://www.ncbi.nlm.nih.gov/pubmed/31641940 http://dx.doi.org/10.1007/s13246-019-00795-w |
work_keys_str_mv | AT xujing anatomicalreductionandpreciseinternalfixationofintraarticularfracturesofthedistalradiuswithvirtualxrayand3dprinting AT zhangguodong anatomicalreductionandpreciseinternalfixationofintraarticularfracturesofthedistalradiuswithvirtualxrayand3dprinting AT hezaopeng anatomicalreductionandpreciseinternalfixationofintraarticularfracturesofthedistalradiuswithvirtualxrayand3dprinting AT zhongshizhen anatomicalreductionandpreciseinternalfixationofintraarticularfracturesofthedistalradiuswithvirtualxrayand3dprinting AT chenyongshao anatomicalreductionandpreciseinternalfixationofintraarticularfracturesofthedistalradiuswithvirtualxrayand3dprinting AT weichunrong anatomicalreductionandpreciseinternalfixationofintraarticularfracturesofthedistalradiuswithvirtualxrayand3dprinting AT zhengyudong anatomicalreductionandpreciseinternalfixationofintraarticularfracturesofthedistalradiuswithvirtualxrayand3dprinting AT linhaibin anatomicalreductionandpreciseinternalfixationofintraarticularfracturesofthedistalradiuswithvirtualxrayand3dprinting AT liwei anatomicalreductionandpreciseinternalfixationofintraarticularfracturesofthedistalradiuswithvirtualxrayand3dprinting AT huangwenhua anatomicalreductionandpreciseinternalfixationofintraarticularfracturesofthedistalradiuswithvirtualxrayand3dprinting |