Cargando…

Evaluation of RNA purification methods by using different blood stabilization tubes: identification of key features for epidemiological studies

OBJECTIVE: Peripheral blood is the most promising source of RNA biomarkers for diagnostic and epidemiological studies, because the presence of disease and prognostic information is reflected in the gene expression pattern. Quality RNA is used by a number of different downstream applications, so the...

Descripción completa

Detalles Bibliográficos
Autores principales: Carrillo-Ávila, J. A., de la Puente, R., Catalina, P., Rejón, J. D., Espín-Vallejo, L., Valdivieso, V., Aguilar-Quesada, R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7026973/
https://www.ncbi.nlm.nih.gov/pubmed/32070402
http://dx.doi.org/10.1186/s13104-020-04943-4
_version_ 1783498771032702976
author Carrillo-Ávila, J. A.
de la Puente, R.
Catalina, P.
Rejón, J. D.
Espín-Vallejo, L.
Valdivieso, V.
Aguilar-Quesada, R.
author_facet Carrillo-Ávila, J. A.
de la Puente, R.
Catalina, P.
Rejón, J. D.
Espín-Vallejo, L.
Valdivieso, V.
Aguilar-Quesada, R.
author_sort Carrillo-Ávila, J. A.
collection PubMed
description OBJECTIVE: Peripheral blood is the most promising source of RNA biomarkers for diagnostic and epidemiological studies, because the presence of disease and prognostic information is reflected in the gene expression pattern. Quality RNA is used by a number of different downstream applications, so the selection of the most appropriate RNA stabilization and purification method is important. We have analyzed the RNA purified from 300 blood samples from 25 donors processed by two technicians using three methodologies with Tempus and PaxGene tubes. RESULTS: The best quality sample results were obtained with the Tempus Spin RNA Isolation Kit and the PaxGene Blood miRNA Kit, although larger amounts of RNA were obtained with the Tempus Spin RNA Isolation Kit. Lower Cq values were observed for RNA and miRNA genes in samples that were tested with PaxGene Blood miRNA Kit and Tempus Spin RNA Isolation Kit respectively. We identify the Tempus Spin RNA Isolation Kit as the most robust methodology, whilst the MagMax for Stabilized Blood Tubes RNA Isolation Kit showed the most instability. For biobanks, which process a large cohort and conduct epidemiological studies, the Tempus Spin RNA Isolation Kit is the most appropriate methodology. The study demonstrates the robustness of real-life procedures.
format Online
Article
Text
id pubmed-7026973
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-70269732020-02-24 Evaluation of RNA purification methods by using different blood stabilization tubes: identification of key features for epidemiological studies Carrillo-Ávila, J. A. de la Puente, R. Catalina, P. Rejón, J. D. Espín-Vallejo, L. Valdivieso, V. Aguilar-Quesada, R. BMC Res Notes Research Note OBJECTIVE: Peripheral blood is the most promising source of RNA biomarkers for diagnostic and epidemiological studies, because the presence of disease and prognostic information is reflected in the gene expression pattern. Quality RNA is used by a number of different downstream applications, so the selection of the most appropriate RNA stabilization and purification method is important. We have analyzed the RNA purified from 300 blood samples from 25 donors processed by two technicians using three methodologies with Tempus and PaxGene tubes. RESULTS: The best quality sample results were obtained with the Tempus Spin RNA Isolation Kit and the PaxGene Blood miRNA Kit, although larger amounts of RNA were obtained with the Tempus Spin RNA Isolation Kit. Lower Cq values were observed for RNA and miRNA genes in samples that were tested with PaxGene Blood miRNA Kit and Tempus Spin RNA Isolation Kit respectively. We identify the Tempus Spin RNA Isolation Kit as the most robust methodology, whilst the MagMax for Stabilized Blood Tubes RNA Isolation Kit showed the most instability. For biobanks, which process a large cohort and conduct epidemiological studies, the Tempus Spin RNA Isolation Kit is the most appropriate methodology. The study demonstrates the robustness of real-life procedures. BioMed Central 2020-02-18 /pmc/articles/PMC7026973/ /pubmed/32070402 http://dx.doi.org/10.1186/s13104-020-04943-4 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Note
Carrillo-Ávila, J. A.
de la Puente, R.
Catalina, P.
Rejón, J. D.
Espín-Vallejo, L.
Valdivieso, V.
Aguilar-Quesada, R.
Evaluation of RNA purification methods by using different blood stabilization tubes: identification of key features for epidemiological studies
title Evaluation of RNA purification methods by using different blood stabilization tubes: identification of key features for epidemiological studies
title_full Evaluation of RNA purification methods by using different blood stabilization tubes: identification of key features for epidemiological studies
title_fullStr Evaluation of RNA purification methods by using different blood stabilization tubes: identification of key features for epidemiological studies
title_full_unstemmed Evaluation of RNA purification methods by using different blood stabilization tubes: identification of key features for epidemiological studies
title_short Evaluation of RNA purification methods by using different blood stabilization tubes: identification of key features for epidemiological studies
title_sort evaluation of rna purification methods by using different blood stabilization tubes: identification of key features for epidemiological studies
topic Research Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7026973/
https://www.ncbi.nlm.nih.gov/pubmed/32070402
http://dx.doi.org/10.1186/s13104-020-04943-4
work_keys_str_mv AT carrilloavilaja evaluationofrnapurificationmethodsbyusingdifferentbloodstabilizationtubesidentificationofkeyfeaturesforepidemiologicalstudies
AT delapuenter evaluationofrnapurificationmethodsbyusingdifferentbloodstabilizationtubesidentificationofkeyfeaturesforepidemiologicalstudies
AT catalinap evaluationofrnapurificationmethodsbyusingdifferentbloodstabilizationtubesidentificationofkeyfeaturesforepidemiologicalstudies
AT rejonjd evaluationofrnapurificationmethodsbyusingdifferentbloodstabilizationtubesidentificationofkeyfeaturesforepidemiologicalstudies
AT espinvallejol evaluationofrnapurificationmethodsbyusingdifferentbloodstabilizationtubesidentificationofkeyfeaturesforepidemiologicalstudies
AT valdiviesov evaluationofrnapurificationmethodsbyusingdifferentbloodstabilizationtubesidentificationofkeyfeaturesforepidemiologicalstudies
AT aguilarquesadar evaluationofrnapurificationmethodsbyusingdifferentbloodstabilizationtubesidentificationofkeyfeaturesforepidemiologicalstudies