Cargando…

How Many Screws Are Needed for Reliable Stability of Extra-articular Nonosteoporotic Distal Radius Fractures Fixed with Volar Locking Plates?

BACKGROUND: We hypothesized that volar locking pate fixation using a minimum number of screws—four in the distal row and two in the shaft of the plate—will provide sufficient stability for unstable extra-articular fractures of the distal radius. We aimed to compare the biomechanical properties of di...

Descripción completa

Detalles Bibliográficos
Autores principales: Jung, Hyoung-Seok, Jung, Han Sol, Baek, Suk-Ho, Lee, Jae Sung
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Orthopaedic Association 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7031436/
https://www.ncbi.nlm.nih.gov/pubmed/32117534
http://dx.doi.org/10.4055/cios.2020.12.1.22
_version_ 1783499378931007488
author Jung, Hyoung-Seok
Jung, Han Sol
Baek, Suk-Ho
Lee, Jae Sung
author_facet Jung, Hyoung-Seok
Jung, Han Sol
Baek, Suk-Ho
Lee, Jae Sung
author_sort Jung, Hyoung-Seok
collection PubMed
description BACKGROUND: We hypothesized that volar locking pate fixation using a minimum number of screws—four in the distal row and two in the shaft of the plate—will provide sufficient stability for unstable extra-articular fractures of the distal radius. We aimed to compare the biomechanical properties of different numbers and locations of screws in volar locking plate fixation and describe the clinical and radiological outcome of plate fixation using a minimum number of screws for distal radius fractures. METHODS: We divided 48 artificial radius fracture bones into four groups (group A–D) based on the number and location of screws used for fixation with volar locking plates. The artificial bone models were subjected to axial compression and volar bending load with a force of 250 N and 80 N, respectively, for 1,000 cycles at a frequency of 1 Hz. We also retrospectively reviewed 42 patients with unstable, extra-articular, distal radius fractures who were treated with volar locking plate fixation using a minimum number of screws. RESULTS: Group A (seven distal screws and three proximal screws) had the highest mean stiffness: 303.7 N/mm under axial compression and 61.1 N/mm under volar bending. Compared with group A, group D (four screws in the distal part and two screws in the shaft) showed significantly lower stiffness; therefore, group D was considered inferior in terms of stability. However, in the fatigue test, neither deformation of the metal plate nor detachment or breakage of the metal screws was observed in all groups. In the clinical study, all fractures united without displacement and satisfactory clinical outcome was obtained. CONCLUSIONS: In the dorsally comminuted, extra-articular, nonosteoporotic distal radius fractures, the minimum number of screws—four in the distal row and two in the shaft—in volar locking plate fixation can provide sufficient stability. Further biomechanical studies involving osteoporotic bone will be necessary to confirm the results because volar plate fixation is most commonly used in patients with osteoporosis.
format Online
Article
Text
id pubmed-7031436
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The Korean Orthopaedic Association
record_format MEDLINE/PubMed
spelling pubmed-70314362020-03-01 How Many Screws Are Needed for Reliable Stability of Extra-articular Nonosteoporotic Distal Radius Fractures Fixed with Volar Locking Plates? Jung, Hyoung-Seok Jung, Han Sol Baek, Suk-Ho Lee, Jae Sung Clin Orthop Surg Original Article BACKGROUND: We hypothesized that volar locking pate fixation using a minimum number of screws—four in the distal row and two in the shaft of the plate—will provide sufficient stability for unstable extra-articular fractures of the distal radius. We aimed to compare the biomechanical properties of different numbers and locations of screws in volar locking plate fixation and describe the clinical and radiological outcome of plate fixation using a minimum number of screws for distal radius fractures. METHODS: We divided 48 artificial radius fracture bones into four groups (group A–D) based on the number and location of screws used for fixation with volar locking plates. The artificial bone models were subjected to axial compression and volar bending load with a force of 250 N and 80 N, respectively, for 1,000 cycles at a frequency of 1 Hz. We also retrospectively reviewed 42 patients with unstable, extra-articular, distal radius fractures who were treated with volar locking plate fixation using a minimum number of screws. RESULTS: Group A (seven distal screws and three proximal screws) had the highest mean stiffness: 303.7 N/mm under axial compression and 61.1 N/mm under volar bending. Compared with group A, group D (four screws in the distal part and two screws in the shaft) showed significantly lower stiffness; therefore, group D was considered inferior in terms of stability. However, in the fatigue test, neither deformation of the metal plate nor detachment or breakage of the metal screws was observed in all groups. In the clinical study, all fractures united without displacement and satisfactory clinical outcome was obtained. CONCLUSIONS: In the dorsally comminuted, extra-articular, nonosteoporotic distal radius fractures, the minimum number of screws—four in the distal row and two in the shaft—in volar locking plate fixation can provide sufficient stability. Further biomechanical studies involving osteoporotic bone will be necessary to confirm the results because volar plate fixation is most commonly used in patients with osteoporosis. The Korean Orthopaedic Association 2020-03 2020-02-13 /pmc/articles/PMC7031436/ /pubmed/32117534 http://dx.doi.org/10.4055/cios.2020.12.1.22 Text en Copyright © 2020 by The Korean Orthopaedic Association http://creativecommons.org/licenses/by-nc/4.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Jung, Hyoung-Seok
Jung, Han Sol
Baek, Suk-Ho
Lee, Jae Sung
How Many Screws Are Needed for Reliable Stability of Extra-articular Nonosteoporotic Distal Radius Fractures Fixed with Volar Locking Plates?
title How Many Screws Are Needed for Reliable Stability of Extra-articular Nonosteoporotic Distal Radius Fractures Fixed with Volar Locking Plates?
title_full How Many Screws Are Needed for Reliable Stability of Extra-articular Nonosteoporotic Distal Radius Fractures Fixed with Volar Locking Plates?
title_fullStr How Many Screws Are Needed for Reliable Stability of Extra-articular Nonosteoporotic Distal Radius Fractures Fixed with Volar Locking Plates?
title_full_unstemmed How Many Screws Are Needed for Reliable Stability of Extra-articular Nonosteoporotic Distal Radius Fractures Fixed with Volar Locking Plates?
title_short How Many Screws Are Needed for Reliable Stability of Extra-articular Nonosteoporotic Distal Radius Fractures Fixed with Volar Locking Plates?
title_sort how many screws are needed for reliable stability of extra-articular nonosteoporotic distal radius fractures fixed with volar locking plates?
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7031436/
https://www.ncbi.nlm.nih.gov/pubmed/32117534
http://dx.doi.org/10.4055/cios.2020.12.1.22
work_keys_str_mv AT junghyoungseok howmanyscrewsareneededforreliablestabilityofextraarticularnonosteoporoticdistalradiusfracturesfixedwithvolarlockingplates
AT junghansol howmanyscrewsareneededforreliablestabilityofextraarticularnonosteoporoticdistalradiusfracturesfixedwithvolarlockingplates
AT baeksukho howmanyscrewsareneededforreliablestabilityofextraarticularnonosteoporoticdistalradiusfracturesfixedwithvolarlockingplates
AT leejaesung howmanyscrewsareneededforreliablestabilityofextraarticularnonosteoporoticdistalradiusfracturesfixedwithvolarlockingplates