Evaluation of the clinical performance of the HISCL‐5000 analyzer in the detection of Krebs von den Lungen‐6 antigen and its diagnostic value in interstitial lung disease

BACKGROUND: The sputum saccharide chain antigen (Krebs von den Lungen‐6 [KL‐6]) is a serum biomarker of lung injury. We aimed to evaluate the clinical performance of the automated immunoassay analyzer HISCL‐5000 in detecting KL‐6 by comparing it with LUMIPULSE G1200 and determine the diagnostic valu...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Jingxian, Huang, Zhifeng, Xue, Mingshan, Huang, Huimin, Zheng, Xiaomao, Zhong, Nanshan, Sun, Baoqing
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7031560/
https://www.ncbi.nlm.nih.gov/pubmed/31691368
http://dx.doi.org/10.1002/jcla.23070
_version_ 1783499401336979456
author Wang, Jingxian
Huang, Zhifeng
Xue, Mingshan
Huang, Huimin
Zheng, Xiaomao
Zhong, Nanshan
Sun, Baoqing
author_facet Wang, Jingxian
Huang, Zhifeng
Xue, Mingshan
Huang, Huimin
Zheng, Xiaomao
Zhong, Nanshan
Sun, Baoqing
author_sort Wang, Jingxian
collection PubMed
description BACKGROUND: The sputum saccharide chain antigen (Krebs von den Lungen‐6 [KL‐6]) is a serum biomarker of lung injury. We aimed to evaluate the clinical performance of the automated immunoassay analyzer HISCL‐5000 in detecting KL‐6 by comparing it with LUMIPULSE G1200 and determine the diagnostic value of KL‐6 in interstitial lung disease (ILD). METHODS: A total of 145 serum samples from patients were tested using the two automated immunoassay analyzers in parallel. RESULTS: With a cutoff level of 500 U/mL, comparing the two systems, the agreement, sensitivity, specificity, and kappa value were 99.20%, 100%, 98.63%, and 0.984 (95% CI, 0.952‐1.000), respectively. Spearman's correlation and ICC showed that there was a strong correlation between serum KL‐6 levels measured by the two systems (r (S) = .991 [95% CI, 0.981‐0.995], ICC = 0.984 [95% CI, 0.978‐0.989], P < .01). The clinical diagnosis agreement rate in both systems was >80%. The kappa value was 0.707 (95% CI, 0.582‐0.832; SYSTEM B) and 0.707 (95% CI, 0.588‐0.826; SYSTEM A). The KL‐6 level in the ILD group (1339.5, 662.5‐2363) was significantly higher than that in the non‐ILD groups (252, 158.5‐353; Mann‐Whitney U = 381.5, P < .01), and the KL‐6 level (1558, 726‐2772.5) in the ILD group detected by SYSTEM A was significantly higher than that in the lung cancer group (339, 207‐424), other respiratory disease group (249, 194‐366), and control group (198, 131.5‐297; Kruskal‐Wallis H = 63.19, P < .01). CONCLUSIONS: HISCL‐5000 showed well‐concordant results with those of HISCL‐5000 in the KL‐6 tests. In patients with ILD, KL‐6 showed a good diagnostic performance.
format Online
Article
Text
id pubmed-7031560
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-70315602020-02-27 Evaluation of the clinical performance of the HISCL‐5000 analyzer in the detection of Krebs von den Lungen‐6 antigen and its diagnostic value in interstitial lung disease Wang, Jingxian Huang, Zhifeng Xue, Mingshan Huang, Huimin Zheng, Xiaomao Zhong, Nanshan Sun, Baoqing J Clin Lab Anal Research Articles BACKGROUND: The sputum saccharide chain antigen (Krebs von den Lungen‐6 [KL‐6]) is a serum biomarker of lung injury. We aimed to evaluate the clinical performance of the automated immunoassay analyzer HISCL‐5000 in detecting KL‐6 by comparing it with LUMIPULSE G1200 and determine the diagnostic value of KL‐6 in interstitial lung disease (ILD). METHODS: A total of 145 serum samples from patients were tested using the two automated immunoassay analyzers in parallel. RESULTS: With a cutoff level of 500 U/mL, comparing the two systems, the agreement, sensitivity, specificity, and kappa value were 99.20%, 100%, 98.63%, and 0.984 (95% CI, 0.952‐1.000), respectively. Spearman's correlation and ICC showed that there was a strong correlation between serum KL‐6 levels measured by the two systems (r (S) = .991 [95% CI, 0.981‐0.995], ICC = 0.984 [95% CI, 0.978‐0.989], P < .01). The clinical diagnosis agreement rate in both systems was >80%. The kappa value was 0.707 (95% CI, 0.582‐0.832; SYSTEM B) and 0.707 (95% CI, 0.588‐0.826; SYSTEM A). The KL‐6 level in the ILD group (1339.5, 662.5‐2363) was significantly higher than that in the non‐ILD groups (252, 158.5‐353; Mann‐Whitney U = 381.5, P < .01), and the KL‐6 level (1558, 726‐2772.5) in the ILD group detected by SYSTEM A was significantly higher than that in the lung cancer group (339, 207‐424), other respiratory disease group (249, 194‐366), and control group (198, 131.5‐297; Kruskal‐Wallis H = 63.19, P < .01). CONCLUSIONS: HISCL‐5000 showed well‐concordant results with those of HISCL‐5000 in the KL‐6 tests. In patients with ILD, KL‐6 showed a good diagnostic performance. John Wiley and Sons Inc. 2019-11-06 /pmc/articles/PMC7031560/ /pubmed/31691368 http://dx.doi.org/10.1002/jcla.23070 Text en © 2019 The Authors. Journal of Clinical Laboratory Analysis Published by Wiley Periodicals, Inc. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Articles
Wang, Jingxian
Huang, Zhifeng
Xue, Mingshan
Huang, Huimin
Zheng, Xiaomao
Zhong, Nanshan
Sun, Baoqing
Evaluation of the clinical performance of the HISCL‐5000 analyzer in the detection of Krebs von den Lungen‐6 antigen and its diagnostic value in interstitial lung disease
title Evaluation of the clinical performance of the HISCL‐5000 analyzer in the detection of Krebs von den Lungen‐6 antigen and its diagnostic value in interstitial lung disease
title_full Evaluation of the clinical performance of the HISCL‐5000 analyzer in the detection of Krebs von den Lungen‐6 antigen and its diagnostic value in interstitial lung disease
title_fullStr Evaluation of the clinical performance of the HISCL‐5000 analyzer in the detection of Krebs von den Lungen‐6 antigen and its diagnostic value in interstitial lung disease
title_full_unstemmed Evaluation of the clinical performance of the HISCL‐5000 analyzer in the detection of Krebs von den Lungen‐6 antigen and its diagnostic value in interstitial lung disease
title_short Evaluation of the clinical performance of the HISCL‐5000 analyzer in the detection of Krebs von den Lungen‐6 antigen and its diagnostic value in interstitial lung disease
title_sort evaluation of the clinical performance of the hiscl‐5000 analyzer in the detection of krebs von den lungen‐6 antigen and its diagnostic value in interstitial lung disease
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7031560/
https://www.ncbi.nlm.nih.gov/pubmed/31691368
http://dx.doi.org/10.1002/jcla.23070
work_keys_str_mv AT wangjingxian evaluationoftheclinicalperformanceofthehiscl5000analyzerinthedetectionofkrebsvondenlungen6antigenanditsdiagnosticvalueininterstitiallungdisease
AT huangzhifeng evaluationoftheclinicalperformanceofthehiscl5000analyzerinthedetectionofkrebsvondenlungen6antigenanditsdiagnosticvalueininterstitiallungdisease
AT xuemingshan evaluationoftheclinicalperformanceofthehiscl5000analyzerinthedetectionofkrebsvondenlungen6antigenanditsdiagnosticvalueininterstitiallungdisease
AT huanghuimin evaluationoftheclinicalperformanceofthehiscl5000analyzerinthedetectionofkrebsvondenlungen6antigenanditsdiagnosticvalueininterstitiallungdisease
AT zhengxiaomao evaluationoftheclinicalperformanceofthehiscl5000analyzerinthedetectionofkrebsvondenlungen6antigenanditsdiagnosticvalueininterstitiallungdisease
AT zhongnanshan evaluationoftheclinicalperformanceofthehiscl5000analyzerinthedetectionofkrebsvondenlungen6antigenanditsdiagnosticvalueininterstitiallungdisease
AT sunbaoqing evaluationoftheclinicalperformanceofthehiscl5000analyzerinthedetectionofkrebsvondenlungen6antigenanditsdiagnosticvalueininterstitiallungdisease