Cargando…
Evaluation of the clinical performance of the HISCL‐5000 analyzer in the detection of Krebs von den Lungen‐6 antigen and its diagnostic value in interstitial lung disease
BACKGROUND: The sputum saccharide chain antigen (Krebs von den Lungen‐6 [KL‐6]) is a serum biomarker of lung injury. We aimed to evaluate the clinical performance of the automated immunoassay analyzer HISCL‐5000 in detecting KL‐6 by comparing it with LUMIPULSE G1200 and determine the diagnostic valu...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7031560/ https://www.ncbi.nlm.nih.gov/pubmed/31691368 http://dx.doi.org/10.1002/jcla.23070 |
_version_ | 1783499401336979456 |
---|---|
author | Wang, Jingxian Huang, Zhifeng Xue, Mingshan Huang, Huimin Zheng, Xiaomao Zhong, Nanshan Sun, Baoqing |
author_facet | Wang, Jingxian Huang, Zhifeng Xue, Mingshan Huang, Huimin Zheng, Xiaomao Zhong, Nanshan Sun, Baoqing |
author_sort | Wang, Jingxian |
collection | PubMed |
description | BACKGROUND: The sputum saccharide chain antigen (Krebs von den Lungen‐6 [KL‐6]) is a serum biomarker of lung injury. We aimed to evaluate the clinical performance of the automated immunoassay analyzer HISCL‐5000 in detecting KL‐6 by comparing it with LUMIPULSE G1200 and determine the diagnostic value of KL‐6 in interstitial lung disease (ILD). METHODS: A total of 145 serum samples from patients were tested using the two automated immunoassay analyzers in parallel. RESULTS: With a cutoff level of 500 U/mL, comparing the two systems, the agreement, sensitivity, specificity, and kappa value were 99.20%, 100%, 98.63%, and 0.984 (95% CI, 0.952‐1.000), respectively. Spearman's correlation and ICC showed that there was a strong correlation between serum KL‐6 levels measured by the two systems (r (S) = .991 [95% CI, 0.981‐0.995], ICC = 0.984 [95% CI, 0.978‐0.989], P < .01). The clinical diagnosis agreement rate in both systems was >80%. The kappa value was 0.707 (95% CI, 0.582‐0.832; SYSTEM B) and 0.707 (95% CI, 0.588‐0.826; SYSTEM A). The KL‐6 level in the ILD group (1339.5, 662.5‐2363) was significantly higher than that in the non‐ILD groups (252, 158.5‐353; Mann‐Whitney U = 381.5, P < .01), and the KL‐6 level (1558, 726‐2772.5) in the ILD group detected by SYSTEM A was significantly higher than that in the lung cancer group (339, 207‐424), other respiratory disease group (249, 194‐366), and control group (198, 131.5‐297; Kruskal‐Wallis H = 63.19, P < .01). CONCLUSIONS: HISCL‐5000 showed well‐concordant results with those of HISCL‐5000 in the KL‐6 tests. In patients with ILD, KL‐6 showed a good diagnostic performance. |
format | Online Article Text |
id | pubmed-7031560 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-70315602020-02-27 Evaluation of the clinical performance of the HISCL‐5000 analyzer in the detection of Krebs von den Lungen‐6 antigen and its diagnostic value in interstitial lung disease Wang, Jingxian Huang, Zhifeng Xue, Mingshan Huang, Huimin Zheng, Xiaomao Zhong, Nanshan Sun, Baoqing J Clin Lab Anal Research Articles BACKGROUND: The sputum saccharide chain antigen (Krebs von den Lungen‐6 [KL‐6]) is a serum biomarker of lung injury. We aimed to evaluate the clinical performance of the automated immunoassay analyzer HISCL‐5000 in detecting KL‐6 by comparing it with LUMIPULSE G1200 and determine the diagnostic value of KL‐6 in interstitial lung disease (ILD). METHODS: A total of 145 serum samples from patients were tested using the two automated immunoassay analyzers in parallel. RESULTS: With a cutoff level of 500 U/mL, comparing the two systems, the agreement, sensitivity, specificity, and kappa value were 99.20%, 100%, 98.63%, and 0.984 (95% CI, 0.952‐1.000), respectively. Spearman's correlation and ICC showed that there was a strong correlation between serum KL‐6 levels measured by the two systems (r (S) = .991 [95% CI, 0.981‐0.995], ICC = 0.984 [95% CI, 0.978‐0.989], P < .01). The clinical diagnosis agreement rate in both systems was >80%. The kappa value was 0.707 (95% CI, 0.582‐0.832; SYSTEM B) and 0.707 (95% CI, 0.588‐0.826; SYSTEM A). The KL‐6 level in the ILD group (1339.5, 662.5‐2363) was significantly higher than that in the non‐ILD groups (252, 158.5‐353; Mann‐Whitney U = 381.5, P < .01), and the KL‐6 level (1558, 726‐2772.5) in the ILD group detected by SYSTEM A was significantly higher than that in the lung cancer group (339, 207‐424), other respiratory disease group (249, 194‐366), and control group (198, 131.5‐297; Kruskal‐Wallis H = 63.19, P < .01). CONCLUSIONS: HISCL‐5000 showed well‐concordant results with those of HISCL‐5000 in the KL‐6 tests. In patients with ILD, KL‐6 showed a good diagnostic performance. John Wiley and Sons Inc. 2019-11-06 /pmc/articles/PMC7031560/ /pubmed/31691368 http://dx.doi.org/10.1002/jcla.23070 Text en © 2019 The Authors. Journal of Clinical Laboratory Analysis Published by Wiley Periodicals, Inc. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Articles Wang, Jingxian Huang, Zhifeng Xue, Mingshan Huang, Huimin Zheng, Xiaomao Zhong, Nanshan Sun, Baoqing Evaluation of the clinical performance of the HISCL‐5000 analyzer in the detection of Krebs von den Lungen‐6 antigen and its diagnostic value in interstitial lung disease |
title | Evaluation of the clinical performance of the HISCL‐5000 analyzer in the detection of Krebs von den Lungen‐6 antigen and its diagnostic value in interstitial lung disease |
title_full | Evaluation of the clinical performance of the HISCL‐5000 analyzer in the detection of Krebs von den Lungen‐6 antigen and its diagnostic value in interstitial lung disease |
title_fullStr | Evaluation of the clinical performance of the HISCL‐5000 analyzer in the detection of Krebs von den Lungen‐6 antigen and its diagnostic value in interstitial lung disease |
title_full_unstemmed | Evaluation of the clinical performance of the HISCL‐5000 analyzer in the detection of Krebs von den Lungen‐6 antigen and its diagnostic value in interstitial lung disease |
title_short | Evaluation of the clinical performance of the HISCL‐5000 analyzer in the detection of Krebs von den Lungen‐6 antigen and its diagnostic value in interstitial lung disease |
title_sort | evaluation of the clinical performance of the hiscl‐5000 analyzer in the detection of krebs von den lungen‐6 antigen and its diagnostic value in interstitial lung disease |
topic | Research Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7031560/ https://www.ncbi.nlm.nih.gov/pubmed/31691368 http://dx.doi.org/10.1002/jcla.23070 |
work_keys_str_mv | AT wangjingxian evaluationoftheclinicalperformanceofthehiscl5000analyzerinthedetectionofkrebsvondenlungen6antigenanditsdiagnosticvalueininterstitiallungdisease AT huangzhifeng evaluationoftheclinicalperformanceofthehiscl5000analyzerinthedetectionofkrebsvondenlungen6antigenanditsdiagnosticvalueininterstitiallungdisease AT xuemingshan evaluationoftheclinicalperformanceofthehiscl5000analyzerinthedetectionofkrebsvondenlungen6antigenanditsdiagnosticvalueininterstitiallungdisease AT huanghuimin evaluationoftheclinicalperformanceofthehiscl5000analyzerinthedetectionofkrebsvondenlungen6antigenanditsdiagnosticvalueininterstitiallungdisease AT zhengxiaomao evaluationoftheclinicalperformanceofthehiscl5000analyzerinthedetectionofkrebsvondenlungen6antigenanditsdiagnosticvalueininterstitiallungdisease AT zhongnanshan evaluationoftheclinicalperformanceofthehiscl5000analyzerinthedetectionofkrebsvondenlungen6antigenanditsdiagnosticvalueininterstitiallungdisease AT sunbaoqing evaluationoftheclinicalperformanceofthehiscl5000analyzerinthedetectionofkrebsvondenlungen6antigenanditsdiagnosticvalueininterstitiallungdisease |