Cargando…

Diagnostic performance of a computer-assisted diagnostic system: sensitivity of BONENAVI for bone scintigraphy in patients with disseminated skeletal metastasis is not so high

PURPOSE: Bone scintigraphy (BS) of disseminated skeletal metastasis is sometimes misinterpreted as normal. The use of computer-assisted diagnosis (CAD) may resolve this problem. We investigated the performance of a CAD system, BONENAVI, in the diagnosis of disseminated skeletal metastasis. METHODS:...

Descripción completa

Detalles Bibliográficos
Autores principales: Koizumi, Mitsuru, Motegi, Kazuki, Koyama, Masamichi, Ishiyama, Mitsutomi, Togawa, Takashi, Makino, Tomoko, Arisaka, Yukiko, Terauchi, Takashi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Singapore 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7033060/
https://www.ncbi.nlm.nih.gov/pubmed/31970706
http://dx.doi.org/10.1007/s12149-020-01435-0
_version_ 1783499580778741760
author Koizumi, Mitsuru
Motegi, Kazuki
Koyama, Masamichi
Ishiyama, Mitsutomi
Togawa, Takashi
Makino, Tomoko
Arisaka, Yukiko
Terauchi, Takashi
author_facet Koizumi, Mitsuru
Motegi, Kazuki
Koyama, Masamichi
Ishiyama, Mitsutomi
Togawa, Takashi
Makino, Tomoko
Arisaka, Yukiko
Terauchi, Takashi
author_sort Koizumi, Mitsuru
collection PubMed
description PURPOSE: Bone scintigraphy (BS) of disseminated skeletal metastasis is sometimes misinterpreted as normal. The use of computer-assisted diagnosis (CAD) may resolve this problem. We investigated the performance of a CAD system, BONENAVI, in the diagnosis of disseminated skeletal metastasis. METHODS: Cases of disseminated skeletal metastasis were selected from a BS log. These patients’ BSs were analyzed by BONENAVI to obtain an artificial neural network (ANN) and bone scan index (BSI). Clinical features (type of primary cancer, CT type, and BS type) were compared with the BONENAVI (ANN and BSI) results. The BS findings (diffuse increased axial skeleton uptake, inhomogeneity of uptake, proximal extremity contrast, and degree of renal uptake) and ANN or BSI were evaluated. Then, negative ANN patients were presented. RESULTS: Fifty-four patients were diagnosed as having disseminated skeletal metastasis. Regarding the primary cancers, 12 had prostate cancer, 16 gastric cancers, 16 breast cancers, and 10 miscellaneous cancers. Total sensitivity of ANN (≥ 0.5) was 76% (41/54). ANN values correlated with the BS type among clinical features. Diffuse increased axial skeleton uptake was mostly correlated with ANN of the BS findings. CONCLUSION: The BONENAVI CAD system was partially helpful in diagnosing disseminated skeletal metastasis, but the sensitivity of BONENAVI was not sufficient and underestimated the disseminated skeletal metastasis. Further improvement of this CAD system is necessary to improve the detectability of disseminated skeletal metastasis.
format Online
Article
Text
id pubmed-7033060
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer Singapore
record_format MEDLINE/PubMed
spelling pubmed-70330602020-03-06 Diagnostic performance of a computer-assisted diagnostic system: sensitivity of BONENAVI for bone scintigraphy in patients with disseminated skeletal metastasis is not so high Koizumi, Mitsuru Motegi, Kazuki Koyama, Masamichi Ishiyama, Mitsutomi Togawa, Takashi Makino, Tomoko Arisaka, Yukiko Terauchi, Takashi Ann Nucl Med Original Article PURPOSE: Bone scintigraphy (BS) of disseminated skeletal metastasis is sometimes misinterpreted as normal. The use of computer-assisted diagnosis (CAD) may resolve this problem. We investigated the performance of a CAD system, BONENAVI, in the diagnosis of disseminated skeletal metastasis. METHODS: Cases of disseminated skeletal metastasis were selected from a BS log. These patients’ BSs were analyzed by BONENAVI to obtain an artificial neural network (ANN) and bone scan index (BSI). Clinical features (type of primary cancer, CT type, and BS type) were compared with the BONENAVI (ANN and BSI) results. The BS findings (diffuse increased axial skeleton uptake, inhomogeneity of uptake, proximal extremity contrast, and degree of renal uptake) and ANN or BSI were evaluated. Then, negative ANN patients were presented. RESULTS: Fifty-four patients were diagnosed as having disseminated skeletal metastasis. Regarding the primary cancers, 12 had prostate cancer, 16 gastric cancers, 16 breast cancers, and 10 miscellaneous cancers. Total sensitivity of ANN (≥ 0.5) was 76% (41/54). ANN values correlated with the BS type among clinical features. Diffuse increased axial skeleton uptake was mostly correlated with ANN of the BS findings. CONCLUSION: The BONENAVI CAD system was partially helpful in diagnosing disseminated skeletal metastasis, but the sensitivity of BONENAVI was not sufficient and underestimated the disseminated skeletal metastasis. Further improvement of this CAD system is necessary to improve the detectability of disseminated skeletal metastasis. Springer Singapore 2020-01-22 2020 /pmc/articles/PMC7033060/ /pubmed/31970706 http://dx.doi.org/10.1007/s12149-020-01435-0 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Original Article
Koizumi, Mitsuru
Motegi, Kazuki
Koyama, Masamichi
Ishiyama, Mitsutomi
Togawa, Takashi
Makino, Tomoko
Arisaka, Yukiko
Terauchi, Takashi
Diagnostic performance of a computer-assisted diagnostic system: sensitivity of BONENAVI for bone scintigraphy in patients with disseminated skeletal metastasis is not so high
title Diagnostic performance of a computer-assisted diagnostic system: sensitivity of BONENAVI for bone scintigraphy in patients with disseminated skeletal metastasis is not so high
title_full Diagnostic performance of a computer-assisted diagnostic system: sensitivity of BONENAVI for bone scintigraphy in patients with disseminated skeletal metastasis is not so high
title_fullStr Diagnostic performance of a computer-assisted diagnostic system: sensitivity of BONENAVI for bone scintigraphy in patients with disseminated skeletal metastasis is not so high
title_full_unstemmed Diagnostic performance of a computer-assisted diagnostic system: sensitivity of BONENAVI for bone scintigraphy in patients with disseminated skeletal metastasis is not so high
title_short Diagnostic performance of a computer-assisted diagnostic system: sensitivity of BONENAVI for bone scintigraphy in patients with disseminated skeletal metastasis is not so high
title_sort diagnostic performance of a computer-assisted diagnostic system: sensitivity of bonenavi for bone scintigraphy in patients with disseminated skeletal metastasis is not so high
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7033060/
https://www.ncbi.nlm.nih.gov/pubmed/31970706
http://dx.doi.org/10.1007/s12149-020-01435-0
work_keys_str_mv AT koizumimitsuru diagnosticperformanceofacomputerassisteddiagnosticsystemsensitivityofbonenaviforbonescintigraphyinpatientswithdisseminatedskeletalmetastasisisnotsohigh
AT motegikazuki diagnosticperformanceofacomputerassisteddiagnosticsystemsensitivityofbonenaviforbonescintigraphyinpatientswithdisseminatedskeletalmetastasisisnotsohigh
AT koyamamasamichi diagnosticperformanceofacomputerassisteddiagnosticsystemsensitivityofbonenaviforbonescintigraphyinpatientswithdisseminatedskeletalmetastasisisnotsohigh
AT ishiyamamitsutomi diagnosticperformanceofacomputerassisteddiagnosticsystemsensitivityofbonenaviforbonescintigraphyinpatientswithdisseminatedskeletalmetastasisisnotsohigh
AT togawatakashi diagnosticperformanceofacomputerassisteddiagnosticsystemsensitivityofbonenaviforbonescintigraphyinpatientswithdisseminatedskeletalmetastasisisnotsohigh
AT makinotomoko diagnosticperformanceofacomputerassisteddiagnosticsystemsensitivityofbonenaviforbonescintigraphyinpatientswithdisseminatedskeletalmetastasisisnotsohigh
AT arisakayukiko diagnosticperformanceofacomputerassisteddiagnosticsystemsensitivityofbonenaviforbonescintigraphyinpatientswithdisseminatedskeletalmetastasisisnotsohigh
AT terauchitakashi diagnosticperformanceofacomputerassisteddiagnosticsystemsensitivityofbonenaviforbonescintigraphyinpatientswithdisseminatedskeletalmetastasisisnotsohigh