Cargando…

Mediastinal bronchial artery aneurysm with short inflow segment successfully treated with a patent ductus arteriosus occluder device

Bronchial artery aneurysm (BAA) is a rare vascular abnormality that may result in life-threatening bleeding if it is left untreated. We present the case of a 35-year-old man with a mediastinal BAA characterized by a short inflow artery segment and tortuous single outflow vessel. The patient's B...

Descripción completa

Detalles Bibliográficos
Autores principales: Patel, Neeral R., Sidiqi, Abdulwahab, Qazi, Abdul Aziz, Jaberi, Arash, Forbes, Thomas L., Tan, Kong Teng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7033448/
https://www.ncbi.nlm.nih.gov/pubmed/32095664
http://dx.doi.org/10.1016/j.jvscit.2019.12.005
_version_ 1783499669229273088
author Patel, Neeral R.
Sidiqi, Abdulwahab
Qazi, Abdul Aziz
Jaberi, Arash
Forbes, Thomas L.
Tan, Kong Teng
author_facet Patel, Neeral R.
Sidiqi, Abdulwahab
Qazi, Abdul Aziz
Jaberi, Arash
Forbes, Thomas L.
Tan, Kong Teng
author_sort Patel, Neeral R.
collection PubMed
description Bronchial artery aneurysm (BAA) is a rare vascular abnormality that may result in life-threatening bleeding if it is left untreated. We present the case of a 35-year-old man with a mediastinal BAA characterized by a short inflow artery segment and tortuous single outflow vessel. The patient's BAA was treated with a novel approach involving placement of a patent ductus arteriosus closure device in the short inflow segment as well as coil embolization of the outflow vessel, successfully excluding the BAA. Two-week follow-up revealed no flow in the embolized artery on computed tomography angiography. This case demonstrates the first successful use of a patent ductus arteriosus occluder device in the treatment of a mediastinal BAA with short inflow segment.
format Online
Article
Text
id pubmed-7033448
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-70334482020-02-24 Mediastinal bronchial artery aneurysm with short inflow segment successfully treated with a patent ductus arteriosus occluder device Patel, Neeral R. Sidiqi, Abdulwahab Qazi, Abdul Aziz Jaberi, Arash Forbes, Thomas L. Tan, Kong Teng J Vasc Surg Cases Innov Tech Case report Bronchial artery aneurysm (BAA) is a rare vascular abnormality that may result in life-threatening bleeding if it is left untreated. We present the case of a 35-year-old man with a mediastinal BAA characterized by a short inflow artery segment and tortuous single outflow vessel. The patient's BAA was treated with a novel approach involving placement of a patent ductus arteriosus closure device in the short inflow segment as well as coil embolization of the outflow vessel, successfully excluding the BAA. Two-week follow-up revealed no flow in the embolized artery on computed tomography angiography. This case demonstrates the first successful use of a patent ductus arteriosus occluder device in the treatment of a mediastinal BAA with short inflow segment. Elsevier 2020-02-20 /pmc/articles/PMC7033448/ /pubmed/32095664 http://dx.doi.org/10.1016/j.jvscit.2019.12.005 Text en © 2019 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case report
Patel, Neeral R.
Sidiqi, Abdulwahab
Qazi, Abdul Aziz
Jaberi, Arash
Forbes, Thomas L.
Tan, Kong Teng
Mediastinal bronchial artery aneurysm with short inflow segment successfully treated with a patent ductus arteriosus occluder device
title Mediastinal bronchial artery aneurysm with short inflow segment successfully treated with a patent ductus arteriosus occluder device
title_full Mediastinal bronchial artery aneurysm with short inflow segment successfully treated with a patent ductus arteriosus occluder device
title_fullStr Mediastinal bronchial artery aneurysm with short inflow segment successfully treated with a patent ductus arteriosus occluder device
title_full_unstemmed Mediastinal bronchial artery aneurysm with short inflow segment successfully treated with a patent ductus arteriosus occluder device
title_short Mediastinal bronchial artery aneurysm with short inflow segment successfully treated with a patent ductus arteriosus occluder device
title_sort mediastinal bronchial artery aneurysm with short inflow segment successfully treated with a patent ductus arteriosus occluder device
topic Case report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7033448/
https://www.ncbi.nlm.nih.gov/pubmed/32095664
http://dx.doi.org/10.1016/j.jvscit.2019.12.005
work_keys_str_mv AT patelneeralr mediastinalbronchialarteryaneurysmwithshortinflowsegmentsuccessfullytreatedwithapatentductusarteriosusoccluderdevice
AT sidiqiabdulwahab mediastinalbronchialarteryaneurysmwithshortinflowsegmentsuccessfullytreatedwithapatentductusarteriosusoccluderdevice
AT qaziabdulaziz mediastinalbronchialarteryaneurysmwithshortinflowsegmentsuccessfullytreatedwithapatentductusarteriosusoccluderdevice
AT jaberiarash mediastinalbronchialarteryaneurysmwithshortinflowsegmentsuccessfullytreatedwithapatentductusarteriosusoccluderdevice
AT forbesthomasl mediastinalbronchialarteryaneurysmwithshortinflowsegmentsuccessfullytreatedwithapatentductusarteriosusoccluderdevice
AT tankongteng mediastinalbronchialarteryaneurysmwithshortinflowsegmentsuccessfullytreatedwithapatentductusarteriosusoccluderdevice