Cargando…

Biometric From Surface Electromyogram (sEMG): Feasibility of User Verification and Identification Based on Gesture Recognition

Electrical biosignals are favored as biometric traits due to their hidden nature and allowing for liveness detection. This study explored the feasibility of surface electromyogram (sEMG), the electrical manifestation of muscle activities, as a biometric trait. The accurate gesture recognition from s...

Descripción completa

Detalles Bibliográficos
Autores principales: He, Jiayuan, Jiang, Ning
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7033497/
https://www.ncbi.nlm.nih.gov/pubmed/32117937
http://dx.doi.org/10.3389/fbioe.2020.00058
_version_ 1783499681217642496
author He, Jiayuan
Jiang, Ning
author_facet He, Jiayuan
Jiang, Ning
author_sort He, Jiayuan
collection PubMed
description Electrical biosignals are favored as biometric traits due to their hidden nature and allowing for liveness detection. This study explored the feasibility of surface electromyogram (sEMG), the electrical manifestation of muscle activities, as a biometric trait. The accurate gesture recognition from sEMG provided a unique advantage over two traditional electrical biosignal traits, electrocardiogram (ECG), and electroencephalogram (EEG), enabling users to customize their own gesture codes. The performance of 16 static wrist and hand gestures was systematically investigated in two identity management modes: verification and identification. The results showed that for a single fixed gesture, using only 0.8-second data, the averaged equal error rate (EER) for verification was 3.5%, and the averaged rank-1 for identification was 90.3%, both comparable to the reported performance of ECG and EEG. The function of customizing gesture code could further improve the verification performance to 1.1% EER. This work demonstrated the potential and effectiveness of sEMG as a biometric trait in user verification and identification, beneficial for the design of future biometric systems.
format Online
Article
Text
id pubmed-7033497
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-70334972020-02-28 Biometric From Surface Electromyogram (sEMG): Feasibility of User Verification and Identification Based on Gesture Recognition He, Jiayuan Jiang, Ning Front Bioeng Biotechnol Bioengineering and Biotechnology Electrical biosignals are favored as biometric traits due to their hidden nature and allowing for liveness detection. This study explored the feasibility of surface electromyogram (sEMG), the electrical manifestation of muscle activities, as a biometric trait. The accurate gesture recognition from sEMG provided a unique advantage over two traditional electrical biosignal traits, electrocardiogram (ECG), and electroencephalogram (EEG), enabling users to customize their own gesture codes. The performance of 16 static wrist and hand gestures was systematically investigated in two identity management modes: verification and identification. The results showed that for a single fixed gesture, using only 0.8-second data, the averaged equal error rate (EER) for verification was 3.5%, and the averaged rank-1 for identification was 90.3%, both comparable to the reported performance of ECG and EEG. The function of customizing gesture code could further improve the verification performance to 1.1% EER. This work demonstrated the potential and effectiveness of sEMG as a biometric trait in user verification and identification, beneficial for the design of future biometric systems. Frontiers Media S.A. 2020-02-14 /pmc/articles/PMC7033497/ /pubmed/32117937 http://dx.doi.org/10.3389/fbioe.2020.00058 Text en Copyright © 2020 He and Jiang. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Bioengineering and Biotechnology
He, Jiayuan
Jiang, Ning
Biometric From Surface Electromyogram (sEMG): Feasibility of User Verification and Identification Based on Gesture Recognition
title Biometric From Surface Electromyogram (sEMG): Feasibility of User Verification and Identification Based on Gesture Recognition
title_full Biometric From Surface Electromyogram (sEMG): Feasibility of User Verification and Identification Based on Gesture Recognition
title_fullStr Biometric From Surface Electromyogram (sEMG): Feasibility of User Verification and Identification Based on Gesture Recognition
title_full_unstemmed Biometric From Surface Electromyogram (sEMG): Feasibility of User Verification and Identification Based on Gesture Recognition
title_short Biometric From Surface Electromyogram (sEMG): Feasibility of User Verification and Identification Based on Gesture Recognition
title_sort biometric from surface electromyogram (semg): feasibility of user verification and identification based on gesture recognition
topic Bioengineering and Biotechnology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7033497/
https://www.ncbi.nlm.nih.gov/pubmed/32117937
http://dx.doi.org/10.3389/fbioe.2020.00058
work_keys_str_mv AT hejiayuan biometricfromsurfaceelectromyogramsemgfeasibilityofuserverificationandidentificationbasedongesturerecognition
AT jiangning biometricfromsurfaceelectromyogramsemgfeasibilityofuserverificationandidentificationbasedongesturerecognition