Cargando…

Magnetic resonance imaging sequence evaluation of an MR Linac system; early clinical experience

OBJECTIVE(S): To systematically identify the preferred magnetic resonance imaging (MRI) sequences following volunteer imaging on a 1.5 Tesla (T) MR-Linear Accelerator (MR Linac) for future protocol development. METHODS: Non-patient volunteers were recruited to a Research and Ethics committee approve...

Descripción completa

Detalles Bibliográficos
Autores principales: Eccles, C.L., Adair Smith, G., Bower, L., Hafeez, S., Herbert, T., Hunt, A., McNair, H.A., Ofuya, Mercy, Oelfke, Uwe, Nill, Simeon, Huddart, R.A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7033780/
https://www.ncbi.nlm.nih.gov/pubmed/32095556
http://dx.doi.org/10.1016/j.tipsro.2019.11.004
_version_ 1783499738146930688
author Eccles, C.L.
Adair Smith, G.
Bower, L.
Hafeez, S.
Herbert, T.
Hunt, A.
McNair, H.A.
Ofuya, Mercy
Oelfke, Uwe
Nill, Simeon
Huddart, R.A.
author_facet Eccles, C.L.
Adair Smith, G.
Bower, L.
Hafeez, S.
Herbert, T.
Hunt, A.
McNair, H.A.
Ofuya, Mercy
Oelfke, Uwe
Nill, Simeon
Huddart, R.A.
author_sort Eccles, C.L.
collection PubMed
description OBJECTIVE(S): To systematically identify the preferred magnetic resonance imaging (MRI) sequences following volunteer imaging on a 1.5 Tesla (T) MR-Linear Accelerator (MR Linac) for future protocol development. METHODS: Non-patient volunteers were recruited to a Research and Ethics committee approved prospective MR-only imaging study on a 1.5T MR Linac system. Volunteers attended 1–3 imaging sessions that included a combination of mDixon, T1w, T2w sequences using 2-dimensional (2D) and 3-dimensional (3D) acquisitions. Each sequence was acquired over 2–7 minutes and reviewed by a panel of 3 observers to evaluate image quality using a visual grading analysis based on a 4-point Likert scale. Sequences were acquired and modified iteratively until deemed fit for purpose (online image matching or re-planning) and all observers agreed they were suitable in 3 volunteers. RESULTS: 26 volunteers underwent 31 imaging sessions of six general anatomical regions. Images were acquired in one or two of six general anatomical regions: male pelvis (n = 9), female pelvis (n = 4), chestwall/breast (n = 5), lung/oesophagus (n = 5), abdomen (n = 3) and head and neck (n = 5). Images were acquired using a pre-defined exam-card that on average, included six sequences (range 2–10), with a maximum scan time of approximately one hour. The majority of observers preferred T2-weighted sequences. The thorax teams were the only groups to prefer T1-weighted imaging. CONCLUSIONS: An iterative process identified sequence agreement in all anatomical regions. These sequences will now be evaluated in patient volunteers. ADVANCES IN KNOWLEDGE: This manuscript is the first publication sharing the results of the first systematic selection of MRI sequences for use in on-board MRI-guided radiotherapy by end-users (therapeutic radiographers and clinical oncologists) in healthy volunteers.
format Online
Article
Text
id pubmed-7033780
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-70337802020-02-24 Magnetic resonance imaging sequence evaluation of an MR Linac system; early clinical experience Eccles, C.L. Adair Smith, G. Bower, L. Hafeez, S. Herbert, T. Hunt, A. McNair, H.A. Ofuya, Mercy Oelfke, Uwe Nill, Simeon Huddart, R.A. Tech Innov Patient Support Radiat Oncol IGART in treatment delivery OBJECTIVE(S): To systematically identify the preferred magnetic resonance imaging (MRI) sequences following volunteer imaging on a 1.5 Tesla (T) MR-Linear Accelerator (MR Linac) for future protocol development. METHODS: Non-patient volunteers were recruited to a Research and Ethics committee approved prospective MR-only imaging study on a 1.5T MR Linac system. Volunteers attended 1–3 imaging sessions that included a combination of mDixon, T1w, T2w sequences using 2-dimensional (2D) and 3-dimensional (3D) acquisitions. Each sequence was acquired over 2–7 minutes and reviewed by a panel of 3 observers to evaluate image quality using a visual grading analysis based on a 4-point Likert scale. Sequences were acquired and modified iteratively until deemed fit for purpose (online image matching or re-planning) and all observers agreed they were suitable in 3 volunteers. RESULTS: 26 volunteers underwent 31 imaging sessions of six general anatomical regions. Images were acquired in one or two of six general anatomical regions: male pelvis (n = 9), female pelvis (n = 4), chestwall/breast (n = 5), lung/oesophagus (n = 5), abdomen (n = 3) and head and neck (n = 5). Images were acquired using a pre-defined exam-card that on average, included six sequences (range 2–10), with a maximum scan time of approximately one hour. The majority of observers preferred T2-weighted sequences. The thorax teams were the only groups to prefer T1-weighted imaging. CONCLUSIONS: An iterative process identified sequence agreement in all anatomical regions. These sequences will now be evaluated in patient volunteers. ADVANCES IN KNOWLEDGE: This manuscript is the first publication sharing the results of the first systematic selection of MRI sequences for use in on-board MRI-guided radiotherapy by end-users (therapeutic radiographers and clinical oncologists) in healthy volunteers. Elsevier 2019-12-16 /pmc/articles/PMC7033780/ /pubmed/32095556 http://dx.doi.org/10.1016/j.tipsro.2019.11.004 Text en © 2019 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle IGART in treatment delivery
Eccles, C.L.
Adair Smith, G.
Bower, L.
Hafeez, S.
Herbert, T.
Hunt, A.
McNair, H.A.
Ofuya, Mercy
Oelfke, Uwe
Nill, Simeon
Huddart, R.A.
Magnetic resonance imaging sequence evaluation of an MR Linac system; early clinical experience
title Magnetic resonance imaging sequence evaluation of an MR Linac system; early clinical experience
title_full Magnetic resonance imaging sequence evaluation of an MR Linac system; early clinical experience
title_fullStr Magnetic resonance imaging sequence evaluation of an MR Linac system; early clinical experience
title_full_unstemmed Magnetic resonance imaging sequence evaluation of an MR Linac system; early clinical experience
title_short Magnetic resonance imaging sequence evaluation of an MR Linac system; early clinical experience
title_sort magnetic resonance imaging sequence evaluation of an mr linac system; early clinical experience
topic IGART in treatment delivery
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7033780/
https://www.ncbi.nlm.nih.gov/pubmed/32095556
http://dx.doi.org/10.1016/j.tipsro.2019.11.004
work_keys_str_mv AT ecclescl magneticresonanceimagingsequenceevaluationofanmrlinacsystemearlyclinicalexperience
AT adairsmithg magneticresonanceimagingsequenceevaluationofanmrlinacsystemearlyclinicalexperience
AT bowerl magneticresonanceimagingsequenceevaluationofanmrlinacsystemearlyclinicalexperience
AT hafeezs magneticresonanceimagingsequenceevaluationofanmrlinacsystemearlyclinicalexperience
AT herbertt magneticresonanceimagingsequenceevaluationofanmrlinacsystemearlyclinicalexperience
AT hunta magneticresonanceimagingsequenceevaluationofanmrlinacsystemearlyclinicalexperience
AT mcnairha magneticresonanceimagingsequenceevaluationofanmrlinacsystemearlyclinicalexperience
AT ofuyamercy magneticresonanceimagingsequenceevaluationofanmrlinacsystemearlyclinicalexperience
AT oelfkeuwe magneticresonanceimagingsequenceevaluationofanmrlinacsystemearlyclinicalexperience
AT nillsimeon magneticresonanceimagingsequenceevaluationofanmrlinacsystemearlyclinicalexperience
AT huddartra magneticresonanceimagingsequenceevaluationofanmrlinacsystemearlyclinicalexperience
AT magneticresonanceimagingsequenceevaluationofanmrlinacsystemearlyclinicalexperience