Cargando…
Beyond geometrical overlap: a Dosimetrical Evaluation of automated volumes Adaptation (DEA) in head and neck replanning
INTRODUCTION: Automated target volumes adaptation could be useful in H&N replanning, but its dosimetric impact has not been analyzed. Primary aim of this investigation is dose coverage assessment in fully automated and edited PTV adaptation settings, compared to manual benchmark. MATERIALS AND M...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7033794/ https://www.ncbi.nlm.nih.gov/pubmed/32095559 http://dx.doi.org/10.1016/j.tipsro.2017.06.002 |
_version_ | 1783499741363961856 |
---|---|
author | Mattiucci, Gian Carlo Boldrini, Luca Placidi, Lorenzo Azario, Luigi Dinapoli, Nicola Chiloiro, Giuditta Pasini, Danilo Piccari, Danila Gambacorta, Maria Antonietta Balducci, Mario Mantini, Giovanna Valentini, Vincenzo |
author_facet | Mattiucci, Gian Carlo Boldrini, Luca Placidi, Lorenzo Azario, Luigi Dinapoli, Nicola Chiloiro, Giuditta Pasini, Danilo Piccari, Danila Gambacorta, Maria Antonietta Balducci, Mario Mantini, Giovanna Valentini, Vincenzo |
author_sort | Mattiucci, Gian Carlo |
collection | PubMed |
description | INTRODUCTION: Automated target volumes adaptation could be useful in H&N replanning, but its dosimetric impact has not been analyzed. Primary aim of this investigation is dose coverage assessment in fully automated and edited PTV adaptation settings, compared to manual benchmark. MATERIALS AND METHODS: Ten IMRT patients were selected and replanning CTs were acquired. A deformable registration with PTV adaptation was performed defining PTVA. PTV B was obtained through manual editing and a benchmark PTV C was manually segmented by a delineation team. The Dice Similarity Index (DSI) and the mean Hausdorff Distance (mHD) were calculated between PTV A and PTV C, and between PTV B and PTV C. One IMRT plan was realized for each PTV: the plans optimized on PTV A and PTV B were proposed on PTV C to evaluate their dosimetric reliability compared to the benchmark plan in terms of PTV V95% dose coverage. RESULTS: The comparisons between PTV A with PTV C and PTV B with PTV C showed that the better DSI (high) and mHD values (low) are, the smaller difference when compared to PTV C V95% is described. Evaluating plan A and B, PTV C V95% reduced by 6.1 ± 3.0% and by 4.1 ± 2.3% respectively when compared to plan C PTV C V95%. PTV B reaches acceptable dose coverage values (PTV V95% >95%) when DSI is >0.91 and a mHD < 0.17 mm and it has better results when compared to PTV A in 70%. DISCUSSION: The results show a correlation between the DSI-mHD and the PTV V95% variation, in the comparisons PTV A and PTV B vs PTV C. Furthermore, we observed that PTV V95% coverage is higher in PTV B than in PTV A: the use of automated propagation may not be definitive and requires manual correction. |
format | Online Article Text |
id | pubmed-7033794 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-70337942020-02-24 Beyond geometrical overlap: a Dosimetrical Evaluation of automated volumes Adaptation (DEA) in head and neck replanning Mattiucci, Gian Carlo Boldrini, Luca Placidi, Lorenzo Azario, Luigi Dinapoli, Nicola Chiloiro, Giuditta Pasini, Danilo Piccari, Danila Gambacorta, Maria Antonietta Balducci, Mario Mantini, Giovanna Valentini, Vincenzo Tech Innov Patient Support Radiat Oncol Research article INTRODUCTION: Automated target volumes adaptation could be useful in H&N replanning, but its dosimetric impact has not been analyzed. Primary aim of this investigation is dose coverage assessment in fully automated and edited PTV adaptation settings, compared to manual benchmark. MATERIALS AND METHODS: Ten IMRT patients were selected and replanning CTs were acquired. A deformable registration with PTV adaptation was performed defining PTVA. PTV B was obtained through manual editing and a benchmark PTV C was manually segmented by a delineation team. The Dice Similarity Index (DSI) and the mean Hausdorff Distance (mHD) were calculated between PTV A and PTV C, and between PTV B and PTV C. One IMRT plan was realized for each PTV: the plans optimized on PTV A and PTV B were proposed on PTV C to evaluate their dosimetric reliability compared to the benchmark plan in terms of PTV V95% dose coverage. RESULTS: The comparisons between PTV A with PTV C and PTV B with PTV C showed that the better DSI (high) and mHD values (low) are, the smaller difference when compared to PTV C V95% is described. Evaluating plan A and B, PTV C V95% reduced by 6.1 ± 3.0% and by 4.1 ± 2.3% respectively when compared to plan C PTV C V95%. PTV B reaches acceptable dose coverage values (PTV V95% >95%) when DSI is >0.91 and a mHD < 0.17 mm and it has better results when compared to PTV A in 70%. DISCUSSION: The results show a correlation between the DSI-mHD and the PTV V95% variation, in the comparisons PTV A and PTV B vs PTV C. Furthermore, we observed that PTV V95% coverage is higher in PTV B than in PTV A: the use of automated propagation may not be definitive and requires manual correction. Elsevier 2017-07-21 /pmc/articles/PMC7033794/ /pubmed/32095559 http://dx.doi.org/10.1016/j.tipsro.2017.06.002 Text en © 2017 The Authors. Published by Elsevier Ireland Ltd on behalf of European Society for Radiotherapy & Oncology. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Research article Mattiucci, Gian Carlo Boldrini, Luca Placidi, Lorenzo Azario, Luigi Dinapoli, Nicola Chiloiro, Giuditta Pasini, Danilo Piccari, Danila Gambacorta, Maria Antonietta Balducci, Mario Mantini, Giovanna Valentini, Vincenzo Beyond geometrical overlap: a Dosimetrical Evaluation of automated volumes Adaptation (DEA) in head and neck replanning |
title | Beyond geometrical overlap: a Dosimetrical Evaluation of automated volumes Adaptation (DEA) in head and neck replanning |
title_full | Beyond geometrical overlap: a Dosimetrical Evaluation of automated volumes Adaptation (DEA) in head and neck replanning |
title_fullStr | Beyond geometrical overlap: a Dosimetrical Evaluation of automated volumes Adaptation (DEA) in head and neck replanning |
title_full_unstemmed | Beyond geometrical overlap: a Dosimetrical Evaluation of automated volumes Adaptation (DEA) in head and neck replanning |
title_short | Beyond geometrical overlap: a Dosimetrical Evaluation of automated volumes Adaptation (DEA) in head and neck replanning |
title_sort | beyond geometrical overlap: a dosimetrical evaluation of automated volumes adaptation (dea) in head and neck replanning |
topic | Research article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7033794/ https://www.ncbi.nlm.nih.gov/pubmed/32095559 http://dx.doi.org/10.1016/j.tipsro.2017.06.002 |
work_keys_str_mv | AT mattiuccigiancarlo beyondgeometricaloverlapadosimetricalevaluationofautomatedvolumesadaptationdeainheadandneckreplanning AT boldriniluca beyondgeometricaloverlapadosimetricalevaluationofautomatedvolumesadaptationdeainheadandneckreplanning AT placidilorenzo beyondgeometricaloverlapadosimetricalevaluationofautomatedvolumesadaptationdeainheadandneckreplanning AT azarioluigi beyondgeometricaloverlapadosimetricalevaluationofautomatedvolumesadaptationdeainheadandneckreplanning AT dinapolinicola beyondgeometricaloverlapadosimetricalevaluationofautomatedvolumesadaptationdeainheadandneckreplanning AT chiloirogiuditta beyondgeometricaloverlapadosimetricalevaluationofautomatedvolumesadaptationdeainheadandneckreplanning AT pasinidanilo beyondgeometricaloverlapadosimetricalevaluationofautomatedvolumesadaptationdeainheadandneckreplanning AT piccaridanila beyondgeometricaloverlapadosimetricalevaluationofautomatedvolumesadaptationdeainheadandneckreplanning AT gambacortamariaantonietta beyondgeometricaloverlapadosimetricalevaluationofautomatedvolumesadaptationdeainheadandneckreplanning AT balduccimario beyondgeometricaloverlapadosimetricalevaluationofautomatedvolumesadaptationdeainheadandneckreplanning AT mantinigiovanna beyondgeometricaloverlapadosimetricalevaluationofautomatedvolumesadaptationdeainheadandneckreplanning AT valentinivincenzo beyondgeometricaloverlapadosimetricalevaluationofautomatedvolumesadaptationdeainheadandneckreplanning |