Cargando…

Accuracy augmentation of body composition measurement by bioelectrical impedance analyzer in elderly population

Bioelectrical impedance analysis (BIA) is currently the most commonly used method in clinical practice to measure body composition. However, the bioelectrical impedance analyzer is not designed according to different countries, races, and elderly populations. Because different races may have differe...

Descripción completa

Detalles Bibliográficos
Autores principales: Fang, Wen-Hui, Yang, Jie-Ru, Lin, Chih-Ying, Hsiao, Po-Jen, Tu, Ming-Yu, Chen, Chien-Fu, Tsai, Dung-Jang, Su, Wen, Huang, Guo-Shu, Chang, Hung, Su, Sui-Lung
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7035056/
https://www.ncbi.nlm.nih.gov/pubmed/32049818
http://dx.doi.org/10.1097/MD.0000000000019103
_version_ 1783499997674733568
author Fang, Wen-Hui
Yang, Jie-Ru
Lin, Chih-Ying
Hsiao, Po-Jen
Tu, Ming-Yu
Chen, Chien-Fu
Tsai, Dung-Jang
Su, Wen
Huang, Guo-Shu
Chang, Hung
Su, Sui-Lung
author_facet Fang, Wen-Hui
Yang, Jie-Ru
Lin, Chih-Ying
Hsiao, Po-Jen
Tu, Ming-Yu
Chen, Chien-Fu
Tsai, Dung-Jang
Su, Wen
Huang, Guo-Shu
Chang, Hung
Su, Sui-Lung
author_sort Fang, Wen-Hui
collection PubMed
description Bioelectrical impedance analysis (BIA) is currently the most commonly used method in clinical practice to measure body composition. However, the bioelectrical impedance analyzer is not designed according to different countries, races, and elderly populations. Because different races may have different body compositions, a prediction model for the elderly population in Taiwan should be developed to avoid population bias, thereby improving the accuracy of community evaluation surveys. Dual energy X-ray absorptiometry (DXA) was used as a standard method for comparison, and impedance analysis was used for the development of a highly accurate predictive model that is suitable for assessing the body composition of elderly people. This study employed a cross-sectional design and recruited 438 elderly people who were undergoing health examinations at the health management center in the Tri-Service General Hospital as study subjects. Basic demographic variables and impedance analysis values were used in four predictive models, namely, linear regression, random forest, support vector machine (SVM), and eXtreme Gradient Boosting (XGBoost) models, to predict DXA body composition. The data from 354 study subjects were used to develop the predictive model, while the data from 84 study subjects were used to validate the accuracy of the predictive model. The body composition of elderly people as estimated by InBody 720 was highly correlated with that estimated by DXA. The correlation coefficient between InBody 720 and DXA for muscle mass was 0.969, and that for fat mass was 0.935. Consistency analysis results showed that InBody 720 tends to underestimate muscle mass and fat mass. A comparison of the accuracy of the linear regression, random forest, SVM, and XGBoost models showed that the linear regression has the highest accuracy. The correlation coefficient between the new model and DXA for muscle mass and fat mass were 0.977 and 0.978, respectively. The new predictive model can be used to monitor the nutrition status of elderly people and identify people with sarcopenia in the community.
format Online
Article
Text
id pubmed-7035056
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-70350562020-03-10 Accuracy augmentation of body composition measurement by bioelectrical impedance analyzer in elderly population Fang, Wen-Hui Yang, Jie-Ru Lin, Chih-Ying Hsiao, Po-Jen Tu, Ming-Yu Chen, Chien-Fu Tsai, Dung-Jang Su, Wen Huang, Guo-Shu Chang, Hung Su, Sui-Lung Medicine (Baltimore) 4600 Bioelectrical impedance analysis (BIA) is currently the most commonly used method in clinical practice to measure body composition. However, the bioelectrical impedance analyzer is not designed according to different countries, races, and elderly populations. Because different races may have different body compositions, a prediction model for the elderly population in Taiwan should be developed to avoid population bias, thereby improving the accuracy of community evaluation surveys. Dual energy X-ray absorptiometry (DXA) was used as a standard method for comparison, and impedance analysis was used for the development of a highly accurate predictive model that is suitable for assessing the body composition of elderly people. This study employed a cross-sectional design and recruited 438 elderly people who were undergoing health examinations at the health management center in the Tri-Service General Hospital as study subjects. Basic demographic variables and impedance analysis values were used in four predictive models, namely, linear regression, random forest, support vector machine (SVM), and eXtreme Gradient Boosting (XGBoost) models, to predict DXA body composition. The data from 354 study subjects were used to develop the predictive model, while the data from 84 study subjects were used to validate the accuracy of the predictive model. The body composition of elderly people as estimated by InBody 720 was highly correlated with that estimated by DXA. The correlation coefficient between InBody 720 and DXA for muscle mass was 0.969, and that for fat mass was 0.935. Consistency analysis results showed that InBody 720 tends to underestimate muscle mass and fat mass. A comparison of the accuracy of the linear regression, random forest, SVM, and XGBoost models showed that the linear regression has the highest accuracy. The correlation coefficient between the new model and DXA for muscle mass and fat mass were 0.977 and 0.978, respectively. The new predictive model can be used to monitor the nutrition status of elderly people and identify people with sarcopenia in the community. Wolters Kluwer Health 2020-02-14 /pmc/articles/PMC7035056/ /pubmed/32049818 http://dx.doi.org/10.1097/MD.0000000000019103 Text en Copyright © 2020 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by/4.0 This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. http://creativecommons.org/licenses/by/4.0
spellingShingle 4600
Fang, Wen-Hui
Yang, Jie-Ru
Lin, Chih-Ying
Hsiao, Po-Jen
Tu, Ming-Yu
Chen, Chien-Fu
Tsai, Dung-Jang
Su, Wen
Huang, Guo-Shu
Chang, Hung
Su, Sui-Lung
Accuracy augmentation of body composition measurement by bioelectrical impedance analyzer in elderly population
title Accuracy augmentation of body composition measurement by bioelectrical impedance analyzer in elderly population
title_full Accuracy augmentation of body composition measurement by bioelectrical impedance analyzer in elderly population
title_fullStr Accuracy augmentation of body composition measurement by bioelectrical impedance analyzer in elderly population
title_full_unstemmed Accuracy augmentation of body composition measurement by bioelectrical impedance analyzer in elderly population
title_short Accuracy augmentation of body composition measurement by bioelectrical impedance analyzer in elderly population
title_sort accuracy augmentation of body composition measurement by bioelectrical impedance analyzer in elderly population
topic 4600
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7035056/
https://www.ncbi.nlm.nih.gov/pubmed/32049818
http://dx.doi.org/10.1097/MD.0000000000019103
work_keys_str_mv AT fangwenhui accuracyaugmentationofbodycompositionmeasurementbybioelectricalimpedanceanalyzerinelderlypopulation
AT yangjieru accuracyaugmentationofbodycompositionmeasurementbybioelectricalimpedanceanalyzerinelderlypopulation
AT linchihying accuracyaugmentationofbodycompositionmeasurementbybioelectricalimpedanceanalyzerinelderlypopulation
AT hsiaopojen accuracyaugmentationofbodycompositionmeasurementbybioelectricalimpedanceanalyzerinelderlypopulation
AT tumingyu accuracyaugmentationofbodycompositionmeasurementbybioelectricalimpedanceanalyzerinelderlypopulation
AT chenchienfu accuracyaugmentationofbodycompositionmeasurementbybioelectricalimpedanceanalyzerinelderlypopulation
AT tsaidungjang accuracyaugmentationofbodycompositionmeasurementbybioelectricalimpedanceanalyzerinelderlypopulation
AT suwen accuracyaugmentationofbodycompositionmeasurementbybioelectricalimpedanceanalyzerinelderlypopulation
AT huangguoshu accuracyaugmentationofbodycompositionmeasurementbybioelectricalimpedanceanalyzerinelderlypopulation
AT changhung accuracyaugmentationofbodycompositionmeasurementbybioelectricalimpedanceanalyzerinelderlypopulation
AT susuilung accuracyaugmentationofbodycompositionmeasurementbybioelectricalimpedanceanalyzerinelderlypopulation