Cargando…

Biomechanical evaluation of strategies for adjacent segment disease after lateral lumbar interbody fusion: is the extension of pedicle screws necessary?

BACKGROUND: Adjacent segment disease (ASD) is a well-known complication after interbody fusion. Pedicle screw-rod revision possesses sufficient strength and rigidity. However, is a surgical segment with rigid fixation necessary for ASD reoperation? This study aimed to investigate the biomechanical e...

Descripción completa

Detalles Bibliográficos
Autores principales: Liang, Ziyang, Cui, Jianchao, Zhang, Jiarui, He, Jiahui, Tang, Jingjing, Ren, Hui, Ye, Linqiang, Liang, De, Jiang, Xiaobing
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7035718/
https://www.ncbi.nlm.nih.gov/pubmed/32085708
http://dx.doi.org/10.1186/s12891-020-3103-1
_version_ 1783500112684646400
author Liang, Ziyang
Cui, Jianchao
Zhang, Jiarui
He, Jiahui
Tang, Jingjing
Ren, Hui
Ye, Linqiang
Liang, De
Jiang, Xiaobing
author_facet Liang, Ziyang
Cui, Jianchao
Zhang, Jiarui
He, Jiahui
Tang, Jingjing
Ren, Hui
Ye, Linqiang
Liang, De
Jiang, Xiaobing
author_sort Liang, Ziyang
collection PubMed
description BACKGROUND: Adjacent segment disease (ASD) is a well-known complication after interbody fusion. Pedicle screw-rod revision possesses sufficient strength and rigidity. However, is a surgical segment with rigid fixation necessary for ASD reoperation? This study aimed to investigate the biomechanical effect of different instrumentation on lateral lumbar interbody fusion (LLIF) for ASD treatment. METHODS: A validated L2~5 finite element (FE) model was modified for simulation. ASD was considered the level cranial to the upper-instrumented segment (L3/4). Bone graft fusion in LLIF with bilateral pedicle screw (BPS) fixation occurred at L4/5. The ASD segment for each group underwent a) LLIF + posterior extension of BPS, b) PLIF + posterior extension of BPS, c) LLIF + lateral screw, and d) stand-alone LLIF. The L3/4 range of motion (ROM), interbody cage stress and strain, screw-bone interface stress, cage-endplate interface stress, and L2/3 nucleus pulposus of intradiscal pressure (NP-IDP) analysis were calculated for comparisons among the four models. RESULTS: All reconstructive models displayed decreased motion at L3/4. Under each loading condition, the difference was not significant between models a and b, which provided the maximum ROM reduction (73.8 to 97.7% and 68.3 to 98.4%, respectively). Model c also provided a significant ROM reduction (64.9 to 77.5%). Model d provided a minimal restriction of the ROM (18.3 to 90.1%), which exceeded that of model a by 13.1 times for flexion-extension, 10.3 times for lateral bending and 4.8 times for rotation. Model b generated greater cage stress than other models, particularly for flexion. The maximum displacement of the cage and the peak stress of the cage-endplate interface were found to be the highest in model d under all loading conditions. For the screw-bone interface, the stress was much greater with lateral instrumentation than with posterior instrumentation. CONCLUSIONS: Stand-alone LLIF is likely to have limited stability, particularly for lateral bending and axial rotation. Posterior extension of BPS can provide reliable stability and excellent protective effects on instrumentation and endplates. However, LLIF with the use of an in situ screw may be an alternative for ASD reoperation.
format Online
Article
Text
id pubmed-7035718
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-70357182020-03-02 Biomechanical evaluation of strategies for adjacent segment disease after lateral lumbar interbody fusion: is the extension of pedicle screws necessary? Liang, Ziyang Cui, Jianchao Zhang, Jiarui He, Jiahui Tang, Jingjing Ren, Hui Ye, Linqiang Liang, De Jiang, Xiaobing BMC Musculoskelet Disord Research Article BACKGROUND: Adjacent segment disease (ASD) is a well-known complication after interbody fusion. Pedicle screw-rod revision possesses sufficient strength and rigidity. However, is a surgical segment with rigid fixation necessary for ASD reoperation? This study aimed to investigate the biomechanical effect of different instrumentation on lateral lumbar interbody fusion (LLIF) for ASD treatment. METHODS: A validated L2~5 finite element (FE) model was modified for simulation. ASD was considered the level cranial to the upper-instrumented segment (L3/4). Bone graft fusion in LLIF with bilateral pedicle screw (BPS) fixation occurred at L4/5. The ASD segment for each group underwent a) LLIF + posterior extension of BPS, b) PLIF + posterior extension of BPS, c) LLIF + lateral screw, and d) stand-alone LLIF. The L3/4 range of motion (ROM), interbody cage stress and strain, screw-bone interface stress, cage-endplate interface stress, and L2/3 nucleus pulposus of intradiscal pressure (NP-IDP) analysis were calculated for comparisons among the four models. RESULTS: All reconstructive models displayed decreased motion at L3/4. Under each loading condition, the difference was not significant between models a and b, which provided the maximum ROM reduction (73.8 to 97.7% and 68.3 to 98.4%, respectively). Model c also provided a significant ROM reduction (64.9 to 77.5%). Model d provided a minimal restriction of the ROM (18.3 to 90.1%), which exceeded that of model a by 13.1 times for flexion-extension, 10.3 times for lateral bending and 4.8 times for rotation. Model b generated greater cage stress than other models, particularly for flexion. The maximum displacement of the cage and the peak stress of the cage-endplate interface were found to be the highest in model d under all loading conditions. For the screw-bone interface, the stress was much greater with lateral instrumentation than with posterior instrumentation. CONCLUSIONS: Stand-alone LLIF is likely to have limited stability, particularly for lateral bending and axial rotation. Posterior extension of BPS can provide reliable stability and excellent protective effects on instrumentation and endplates. However, LLIF with the use of an in situ screw may be an alternative for ASD reoperation. BioMed Central 2020-02-21 /pmc/articles/PMC7035718/ /pubmed/32085708 http://dx.doi.org/10.1186/s12891-020-3103-1 Text en © The Author(s). 2020 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Liang, Ziyang
Cui, Jianchao
Zhang, Jiarui
He, Jiahui
Tang, Jingjing
Ren, Hui
Ye, Linqiang
Liang, De
Jiang, Xiaobing
Biomechanical evaluation of strategies for adjacent segment disease after lateral lumbar interbody fusion: is the extension of pedicle screws necessary?
title Biomechanical evaluation of strategies for adjacent segment disease after lateral lumbar interbody fusion: is the extension of pedicle screws necessary?
title_full Biomechanical evaluation of strategies for adjacent segment disease after lateral lumbar interbody fusion: is the extension of pedicle screws necessary?
title_fullStr Biomechanical evaluation of strategies for adjacent segment disease after lateral lumbar interbody fusion: is the extension of pedicle screws necessary?
title_full_unstemmed Biomechanical evaluation of strategies for adjacent segment disease after lateral lumbar interbody fusion: is the extension of pedicle screws necessary?
title_short Biomechanical evaluation of strategies for adjacent segment disease after lateral lumbar interbody fusion: is the extension of pedicle screws necessary?
title_sort biomechanical evaluation of strategies for adjacent segment disease after lateral lumbar interbody fusion: is the extension of pedicle screws necessary?
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7035718/
https://www.ncbi.nlm.nih.gov/pubmed/32085708
http://dx.doi.org/10.1186/s12891-020-3103-1
work_keys_str_mv AT liangziyang biomechanicalevaluationofstrategiesforadjacentsegmentdiseaseafterlaterallumbarinterbodyfusionistheextensionofpediclescrewsnecessary
AT cuijianchao biomechanicalevaluationofstrategiesforadjacentsegmentdiseaseafterlaterallumbarinterbodyfusionistheextensionofpediclescrewsnecessary
AT zhangjiarui biomechanicalevaluationofstrategiesforadjacentsegmentdiseaseafterlaterallumbarinterbodyfusionistheextensionofpediclescrewsnecessary
AT hejiahui biomechanicalevaluationofstrategiesforadjacentsegmentdiseaseafterlaterallumbarinterbodyfusionistheextensionofpediclescrewsnecessary
AT tangjingjing biomechanicalevaluationofstrategiesforadjacentsegmentdiseaseafterlaterallumbarinterbodyfusionistheextensionofpediclescrewsnecessary
AT renhui biomechanicalevaluationofstrategiesforadjacentsegmentdiseaseafterlaterallumbarinterbodyfusionistheextensionofpediclescrewsnecessary
AT yelinqiang biomechanicalevaluationofstrategiesforadjacentsegmentdiseaseafterlaterallumbarinterbodyfusionistheextensionofpediclescrewsnecessary
AT liangde biomechanicalevaluationofstrategiesforadjacentsegmentdiseaseafterlaterallumbarinterbodyfusionistheextensionofpediclescrewsnecessary
AT jiangxiaobing biomechanicalevaluationofstrategiesforadjacentsegmentdiseaseafterlaterallumbarinterbodyfusionistheextensionofpediclescrewsnecessary