Cargando…

A Case of Repeating Transient Increase in Intraocular Pressure by Instability of an Intraocular Lens Implanted in the Capsular Bag

We observed repeated episodes of rapid increases in intraocular pressure (IOP) considered to be caused by an in-the-bag intraocular lens (IOL) instability in a patient with an implanted IOL. As acute glaucoma attack-like increase in IOP was noted in the left eye on November 8, she was admitted to Wa...

Descripción completa

Detalles Bibliográficos
Autores principales: Takada, Yukihisa, Sumioka, Takayoshi, Ishikawa, Nobuyuki, Yasuda, Shingo, Komori, Ryoko, Saika, Shizuya
Formato: Online Artículo Texto
Lenguaje:English
Publicado: S. Karger AG 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7036555/
https://www.ncbi.nlm.nih.gov/pubmed/32110231
http://dx.doi.org/10.1159/000505597
_version_ 1783500241304027136
author Takada, Yukihisa
Sumioka, Takayoshi
Ishikawa, Nobuyuki
Yasuda, Shingo
Komori, Ryoko
Saika, Shizuya
author_facet Takada, Yukihisa
Sumioka, Takayoshi
Ishikawa, Nobuyuki
Yasuda, Shingo
Komori, Ryoko
Saika, Shizuya
author_sort Takada, Yukihisa
collection PubMed
description We observed repeated episodes of rapid increases in intraocular pressure (IOP) considered to be caused by an in-the-bag intraocular lens (IOL) instability in a patient with an implanted IOL. As acute glaucoma attack-like increase in IOP was noted in the left eye on November 8, she was admitted to Wakayama Medical University Hospital. The findings at the first examination included an IOP of 62 mm Hg, instability of a PMMA one-piece IOL, shallow anterior chamber, narrow angle, moderate mydriasis, and loss of pupillary light reaction in the left avitreous eye. On November 15, a 6-mm Hg increase in IOP was observed during 60-min dark room prone provocative testing. After the first examination, the patient perceived pain and reduced visual acuity of the left eye and emergently consulted our hospital twice. Despite miosis, normalization of the anterior chamber depth and IOP with widening of the angle were achieved by resting in the supine position. These episodes were thought to be caused by instability and anterior shift of the IOL. On January 17, 2018, suture fixation of the in-the-bag IOL was performed. The IOL was fixed by transscleral suturing of the bilateral supporting parts to the sclera. Recurrence of sudden ophthalmalgia, instability of the in-the-bag IOL, and an increase in IOP have not been observed for 1 year after surgical treatment. Instability of an in-the-bag IOL caused repeated acute angle-closure glaucoma-like attacks. The situation was well treated by suturing and fixing the haptics of IOL to the sclera.
format Online
Article
Text
id pubmed-7036555
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher S. Karger AG
record_format MEDLINE/PubMed
spelling pubmed-70365552020-02-27 A Case of Repeating Transient Increase in Intraocular Pressure by Instability of an Intraocular Lens Implanted in the Capsular Bag Takada, Yukihisa Sumioka, Takayoshi Ishikawa, Nobuyuki Yasuda, Shingo Komori, Ryoko Saika, Shizuya Case Rep Ophthalmol Case Report We observed repeated episodes of rapid increases in intraocular pressure (IOP) considered to be caused by an in-the-bag intraocular lens (IOL) instability in a patient with an implanted IOL. As acute glaucoma attack-like increase in IOP was noted in the left eye on November 8, she was admitted to Wakayama Medical University Hospital. The findings at the first examination included an IOP of 62 mm Hg, instability of a PMMA one-piece IOL, shallow anterior chamber, narrow angle, moderate mydriasis, and loss of pupillary light reaction in the left avitreous eye. On November 15, a 6-mm Hg increase in IOP was observed during 60-min dark room prone provocative testing. After the first examination, the patient perceived pain and reduced visual acuity of the left eye and emergently consulted our hospital twice. Despite miosis, normalization of the anterior chamber depth and IOP with widening of the angle were achieved by resting in the supine position. These episodes were thought to be caused by instability and anterior shift of the IOL. On January 17, 2018, suture fixation of the in-the-bag IOL was performed. The IOL was fixed by transscleral suturing of the bilateral supporting parts to the sclera. Recurrence of sudden ophthalmalgia, instability of the in-the-bag IOL, and an increase in IOP have not been observed for 1 year after surgical treatment. Instability of an in-the-bag IOL caused repeated acute angle-closure glaucoma-like attacks. The situation was well treated by suturing and fixing the haptics of IOL to the sclera. S. Karger AG 2020-01-29 /pmc/articles/PMC7036555/ /pubmed/32110231 http://dx.doi.org/10.1159/000505597 Text en Copyright © 2020 by S. Karger AG, Basel http://creativecommons.org/licenses/by-nc/4.0/ This article is licensed under the Creative Commons Attribution-NonCommercial-4.0 International License (CC BY-NC) (http://www.karger.com/Services/OpenAccessLicense). Usage and distribution for commercial purposes requires written permission.
spellingShingle Case Report
Takada, Yukihisa
Sumioka, Takayoshi
Ishikawa, Nobuyuki
Yasuda, Shingo
Komori, Ryoko
Saika, Shizuya
A Case of Repeating Transient Increase in Intraocular Pressure by Instability of an Intraocular Lens Implanted in the Capsular Bag
title A Case of Repeating Transient Increase in Intraocular Pressure by Instability of an Intraocular Lens Implanted in the Capsular Bag
title_full A Case of Repeating Transient Increase in Intraocular Pressure by Instability of an Intraocular Lens Implanted in the Capsular Bag
title_fullStr A Case of Repeating Transient Increase in Intraocular Pressure by Instability of an Intraocular Lens Implanted in the Capsular Bag
title_full_unstemmed A Case of Repeating Transient Increase in Intraocular Pressure by Instability of an Intraocular Lens Implanted in the Capsular Bag
title_short A Case of Repeating Transient Increase in Intraocular Pressure by Instability of an Intraocular Lens Implanted in the Capsular Bag
title_sort case of repeating transient increase in intraocular pressure by instability of an intraocular lens implanted in the capsular bag
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7036555/
https://www.ncbi.nlm.nih.gov/pubmed/32110231
http://dx.doi.org/10.1159/000505597
work_keys_str_mv AT takadayukihisa acaseofrepeatingtransientincreaseinintraocularpressurebyinstabilityofanintraocularlensimplantedinthecapsularbag
AT sumiokatakayoshi acaseofrepeatingtransientincreaseinintraocularpressurebyinstabilityofanintraocularlensimplantedinthecapsularbag
AT ishikawanobuyuki acaseofrepeatingtransientincreaseinintraocularpressurebyinstabilityofanintraocularlensimplantedinthecapsularbag
AT yasudashingo acaseofrepeatingtransientincreaseinintraocularpressurebyinstabilityofanintraocularlensimplantedinthecapsularbag
AT komoriryoko acaseofrepeatingtransientincreaseinintraocularpressurebyinstabilityofanintraocularlensimplantedinthecapsularbag
AT saikashizuya acaseofrepeatingtransientincreaseinintraocularpressurebyinstabilityofanintraocularlensimplantedinthecapsularbag
AT takadayukihisa caseofrepeatingtransientincreaseinintraocularpressurebyinstabilityofanintraocularlensimplantedinthecapsularbag
AT sumiokatakayoshi caseofrepeatingtransientincreaseinintraocularpressurebyinstabilityofanintraocularlensimplantedinthecapsularbag
AT ishikawanobuyuki caseofrepeatingtransientincreaseinintraocularpressurebyinstabilityofanintraocularlensimplantedinthecapsularbag
AT yasudashingo caseofrepeatingtransientincreaseinintraocularpressurebyinstabilityofanintraocularlensimplantedinthecapsularbag
AT komoriryoko caseofrepeatingtransientincreaseinintraocularpressurebyinstabilityofanintraocularlensimplantedinthecapsularbag
AT saikashizuya caseofrepeatingtransientincreaseinintraocularpressurebyinstabilityofanintraocularlensimplantedinthecapsularbag