Robotic-assisted complete mesocolic excision, central vascular ligation and para-aortic lymph node dissection in multifocal carcinoid: A case report and technical description
INTRODUCTION: Neuroendocrine tumours are the most common type of primary small bowel neoplasm. Consensus guidelines recommend a multimodal approach to treatment of such tumours, with aggressive surgical resection remaining the mainstay of management. There is evidence that complete mesocolic excisio...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7036704/ https://www.ncbi.nlm.nih.gov/pubmed/32092693 http://dx.doi.org/10.1016/j.ijscr.2020.02.018 |
_version_ | 1783500260230823936 |
---|---|
author | Young, R. Rajkomar, A. Smart, P. Warrier, S. |
author_facet | Young, R. Rajkomar, A. Smart, P. Warrier, S. |
author_sort | Young, R. |
collection | PubMed |
description | INTRODUCTION: Neuroendocrine tumours are the most common type of primary small bowel neoplasm. Consensus guidelines recommend a multimodal approach to treatment of such tumours, with aggressive surgical resection remaining the mainstay of management. There is evidence that complete mesocolic excision (CME) of lymph nodes is associated with superior oncological outcomes including longer disease-free survival in patients with colorectal cancer than standard lymph node dissection and there is increasing evidence to suggest that the robotic approach may be superior to laparoscopic or open CME. This report discusses a robotic-assisted approach to CME with central vessel ligation (CVL) and para-aortic lymph node dissection in a case of multifocal neuroendocrine tumour of the small bowel. PRESENTATION OF CASE AND TECHNICAL APPROACH: This report details the case of a 73-year-old male with multifocal small bowel neuroendocrine tumour. He underwent a robotic-assisted right hemicolectomy, small bowel resection, CME, CVL and para-aortic lymph node dissection. The approach described involved undertaking CME, CVL and bowel resection with a standard right hemicolectomy robotic set-up before re-docking the robot to perform the retroperitoneal para-aortic lymph node dissection. DISCUSSION: This case highlights the management of multifocal small bowel neuroendocrine tumour using a robotic approach for surgical resection and lymph node clearance. CONCLUSION: The robotic approach provides a safe and effective technique for undertaking surgical resection of small bowel neuroendocrine tumour as well as complete mesocolic excision of lymph nodes. With a change in port positions, a robotic approach can be utilised for CME/CVL as well as retroperitoneal node dissection. |
format | Online Article Text |
id | pubmed-7036704 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-70367042020-03-02 Robotic-assisted complete mesocolic excision, central vascular ligation and para-aortic lymph node dissection in multifocal carcinoid: A case report and technical description Young, R. Rajkomar, A. Smart, P. Warrier, S. Int J Surg Case Rep Article INTRODUCTION: Neuroendocrine tumours are the most common type of primary small bowel neoplasm. Consensus guidelines recommend a multimodal approach to treatment of such tumours, with aggressive surgical resection remaining the mainstay of management. There is evidence that complete mesocolic excision (CME) of lymph nodes is associated with superior oncological outcomes including longer disease-free survival in patients with colorectal cancer than standard lymph node dissection and there is increasing evidence to suggest that the robotic approach may be superior to laparoscopic or open CME. This report discusses a robotic-assisted approach to CME with central vessel ligation (CVL) and para-aortic lymph node dissection in a case of multifocal neuroendocrine tumour of the small bowel. PRESENTATION OF CASE AND TECHNICAL APPROACH: This report details the case of a 73-year-old male with multifocal small bowel neuroendocrine tumour. He underwent a robotic-assisted right hemicolectomy, small bowel resection, CME, CVL and para-aortic lymph node dissection. The approach described involved undertaking CME, CVL and bowel resection with a standard right hemicolectomy robotic set-up before re-docking the robot to perform the retroperitoneal para-aortic lymph node dissection. DISCUSSION: This case highlights the management of multifocal small bowel neuroendocrine tumour using a robotic approach for surgical resection and lymph node clearance. CONCLUSION: The robotic approach provides a safe and effective technique for undertaking surgical resection of small bowel neuroendocrine tumour as well as complete mesocolic excision of lymph nodes. With a change in port positions, a robotic approach can be utilised for CME/CVL as well as retroperitoneal node dissection. Elsevier 2020-02-11 /pmc/articles/PMC7036704/ /pubmed/32092693 http://dx.doi.org/10.1016/j.ijscr.2020.02.018 Text en © 2020 The Author(s) http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Young, R. Rajkomar, A. Smart, P. Warrier, S. Robotic-assisted complete mesocolic excision, central vascular ligation and para-aortic lymph node dissection in multifocal carcinoid: A case report and technical description |
title | Robotic-assisted complete mesocolic excision, central vascular ligation and para-aortic lymph node dissection in multifocal carcinoid: A case report and technical description |
title_full | Robotic-assisted complete mesocolic excision, central vascular ligation and para-aortic lymph node dissection in multifocal carcinoid: A case report and technical description |
title_fullStr | Robotic-assisted complete mesocolic excision, central vascular ligation and para-aortic lymph node dissection in multifocal carcinoid: A case report and technical description |
title_full_unstemmed | Robotic-assisted complete mesocolic excision, central vascular ligation and para-aortic lymph node dissection in multifocal carcinoid: A case report and technical description |
title_short | Robotic-assisted complete mesocolic excision, central vascular ligation and para-aortic lymph node dissection in multifocal carcinoid: A case report and technical description |
title_sort | robotic-assisted complete mesocolic excision, central vascular ligation and para-aortic lymph node dissection in multifocal carcinoid: a case report and technical description |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7036704/ https://www.ncbi.nlm.nih.gov/pubmed/32092693 http://dx.doi.org/10.1016/j.ijscr.2020.02.018 |
work_keys_str_mv | AT youngr roboticassistedcompletemesocolicexcisioncentralvascularligationandparaaorticlymphnodedissectioninmultifocalcarcinoidacasereportandtechnicaldescription AT rajkomara roboticassistedcompletemesocolicexcisioncentralvascularligationandparaaorticlymphnodedissectioninmultifocalcarcinoidacasereportandtechnicaldescription AT smartp roboticassistedcompletemesocolicexcisioncentralvascularligationandparaaorticlymphnodedissectioninmultifocalcarcinoidacasereportandtechnicaldescription AT warriers roboticassistedcompletemesocolicexcisioncentralvascularligationandparaaorticlymphnodedissectioninmultifocalcarcinoidacasereportandtechnicaldescription |