Cargando…

Transhepatic Insertion of Percutaneous Endoscopic Gastrostomy Tube

Inadvertent injury to interposing organs during percutaneous endoscopic gastrostomy (PEG) tube placement is a feared complication of this common and generally safe procedure. Transhepatic PEG insertion is likely an underrepresented complication which may be identified incidentally on imaging or pres...

Descripción completa

Detalles Bibliográficos
Autores principales: Imam, Zaid, Simons-Linares, C. Roberto
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7037529/
https://www.ncbi.nlm.nih.gov/pubmed/32099694
http://dx.doi.org/10.1155/2020/4516032
Descripción
Sumario:Inadvertent injury to interposing organs during percutaneous endoscopic gastrostomy (PEG) tube placement is a feared complication of this common and generally safe procedure. Transhepatic PEG insertion is likely an underrepresented complication which may be identified incidentally on imaging or present with life-threatening conditions such as sepsis or massive bleeding. Use of ultrasound in patients with known hepatomegaly may possibly help avoid this complication. We hereby report a case of transhepatic PEG insertion, one of 16 only other cases published in the literature, and review the characteristics of the previous reported cases.