Cargando…

A Three-dimensional Finger Motion Measurement System of a Thumb and an Index Finger Without a Calibration Process

Various wearable systems have been investigated to measure hand motion, but some challenges remain. Many systems require a calibration process to map sensor signals to actual finger joint angles by the principle of measuring the length change of the finger, or bending sensors. Also, few studies have...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, Yeongyu, Bae, Joonbum
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7038521/
https://www.ncbi.nlm.nih.gov/pubmed/32019125
http://dx.doi.org/10.3390/s20030756
_version_ 1783500659588333568
author Park, Yeongyu
Bae, Joonbum
author_facet Park, Yeongyu
Bae, Joonbum
author_sort Park, Yeongyu
collection PubMed
description Various wearable systems have been investigated to measure hand motion, but some challenges remain. Many systems require a calibration process to map sensor signals to actual finger joint angles by the principle of measuring the length change of the finger, or bending sensors. Also, few studies have investigated how to measure thumb motion accurately using the wearable systems. This paper proposes an exoskeleton system with linear Hall sensors to measure three-dimensional hand motion without a calibration process. The calibration process is avoided by measuring finger joint angles through an absolute rotation measurement. A new wearing method with lower parts underneath the hand joints and rubber bands is proposed to fix the structure to the hand and adapt it for various hand sizes. As the thumb has a complex biomechanical feature at carpometacarpal (CMC) joint, a new measuring method of the CMC joint is proposed to directly calculate the orientation of the metacarpal. The prototype of the thumb and index finger was manufactured, and the performance was verified experimentally by using an optical motion capture system.
format Online
Article
Text
id pubmed-7038521
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-70385212020-03-09 A Three-dimensional Finger Motion Measurement System of a Thumb and an Index Finger Without a Calibration Process Park, Yeongyu Bae, Joonbum Sensors (Basel) Article Various wearable systems have been investigated to measure hand motion, but some challenges remain. Many systems require a calibration process to map sensor signals to actual finger joint angles by the principle of measuring the length change of the finger, or bending sensors. Also, few studies have investigated how to measure thumb motion accurately using the wearable systems. This paper proposes an exoskeleton system with linear Hall sensors to measure three-dimensional hand motion without a calibration process. The calibration process is avoided by measuring finger joint angles through an absolute rotation measurement. A new wearing method with lower parts underneath the hand joints and rubber bands is proposed to fix the structure to the hand and adapt it for various hand sizes. As the thumb has a complex biomechanical feature at carpometacarpal (CMC) joint, a new measuring method of the CMC joint is proposed to directly calculate the orientation of the metacarpal. The prototype of the thumb and index finger was manufactured, and the performance was verified experimentally by using an optical motion capture system. MDPI 2020-01-30 /pmc/articles/PMC7038521/ /pubmed/32019125 http://dx.doi.org/10.3390/s20030756 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Park, Yeongyu
Bae, Joonbum
A Three-dimensional Finger Motion Measurement System of a Thumb and an Index Finger Without a Calibration Process
title A Three-dimensional Finger Motion Measurement System of a Thumb and an Index Finger Without a Calibration Process
title_full A Three-dimensional Finger Motion Measurement System of a Thumb and an Index Finger Without a Calibration Process
title_fullStr A Three-dimensional Finger Motion Measurement System of a Thumb and an Index Finger Without a Calibration Process
title_full_unstemmed A Three-dimensional Finger Motion Measurement System of a Thumb and an Index Finger Without a Calibration Process
title_short A Three-dimensional Finger Motion Measurement System of a Thumb and an Index Finger Without a Calibration Process
title_sort three-dimensional finger motion measurement system of a thumb and an index finger without a calibration process
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7038521/
https://www.ncbi.nlm.nih.gov/pubmed/32019125
http://dx.doi.org/10.3390/s20030756
work_keys_str_mv AT parkyeongyu athreedimensionalfingermotionmeasurementsystemofathumbandanindexfingerwithoutacalibrationprocess
AT baejoonbum athreedimensionalfingermotionmeasurementsystemofathumbandanindexfingerwithoutacalibrationprocess
AT parkyeongyu threedimensionalfingermotionmeasurementsystemofathumbandanindexfingerwithoutacalibrationprocess
AT baejoonbum threedimensionalfingermotionmeasurementsystemofathumbandanindexfingerwithoutacalibrationprocess