Cargando…
A Three-dimensional Finger Motion Measurement System of a Thumb and an Index Finger Without a Calibration Process
Various wearable systems have been investigated to measure hand motion, but some challenges remain. Many systems require a calibration process to map sensor signals to actual finger joint angles by the principle of measuring the length change of the finger, or bending sensors. Also, few studies have...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7038521/ https://www.ncbi.nlm.nih.gov/pubmed/32019125 http://dx.doi.org/10.3390/s20030756 |
_version_ | 1783500659588333568 |
---|---|
author | Park, Yeongyu Bae, Joonbum |
author_facet | Park, Yeongyu Bae, Joonbum |
author_sort | Park, Yeongyu |
collection | PubMed |
description | Various wearable systems have been investigated to measure hand motion, but some challenges remain. Many systems require a calibration process to map sensor signals to actual finger joint angles by the principle of measuring the length change of the finger, or bending sensors. Also, few studies have investigated how to measure thumb motion accurately using the wearable systems. This paper proposes an exoskeleton system with linear Hall sensors to measure three-dimensional hand motion without a calibration process. The calibration process is avoided by measuring finger joint angles through an absolute rotation measurement. A new wearing method with lower parts underneath the hand joints and rubber bands is proposed to fix the structure to the hand and adapt it for various hand sizes. As the thumb has a complex biomechanical feature at carpometacarpal (CMC) joint, a new measuring method of the CMC joint is proposed to directly calculate the orientation of the metacarpal. The prototype of the thumb and index finger was manufactured, and the performance was verified experimentally by using an optical motion capture system. |
format | Online Article Text |
id | pubmed-7038521 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-70385212020-03-09 A Three-dimensional Finger Motion Measurement System of a Thumb and an Index Finger Without a Calibration Process Park, Yeongyu Bae, Joonbum Sensors (Basel) Article Various wearable systems have been investigated to measure hand motion, but some challenges remain. Many systems require a calibration process to map sensor signals to actual finger joint angles by the principle of measuring the length change of the finger, or bending sensors. Also, few studies have investigated how to measure thumb motion accurately using the wearable systems. This paper proposes an exoskeleton system with linear Hall sensors to measure three-dimensional hand motion without a calibration process. The calibration process is avoided by measuring finger joint angles through an absolute rotation measurement. A new wearing method with lower parts underneath the hand joints and rubber bands is proposed to fix the structure to the hand and adapt it for various hand sizes. As the thumb has a complex biomechanical feature at carpometacarpal (CMC) joint, a new measuring method of the CMC joint is proposed to directly calculate the orientation of the metacarpal. The prototype of the thumb and index finger was manufactured, and the performance was verified experimentally by using an optical motion capture system. MDPI 2020-01-30 /pmc/articles/PMC7038521/ /pubmed/32019125 http://dx.doi.org/10.3390/s20030756 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Park, Yeongyu Bae, Joonbum A Three-dimensional Finger Motion Measurement System of a Thumb and an Index Finger Without a Calibration Process |
title | A Three-dimensional Finger Motion Measurement System of a Thumb and an Index Finger Without a Calibration Process |
title_full | A Three-dimensional Finger Motion Measurement System of a Thumb and an Index Finger Without a Calibration Process |
title_fullStr | A Three-dimensional Finger Motion Measurement System of a Thumb and an Index Finger Without a Calibration Process |
title_full_unstemmed | A Three-dimensional Finger Motion Measurement System of a Thumb and an Index Finger Without a Calibration Process |
title_short | A Three-dimensional Finger Motion Measurement System of a Thumb and an Index Finger Without a Calibration Process |
title_sort | three-dimensional finger motion measurement system of a thumb and an index finger without a calibration process |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7038521/ https://www.ncbi.nlm.nih.gov/pubmed/32019125 http://dx.doi.org/10.3390/s20030756 |
work_keys_str_mv | AT parkyeongyu athreedimensionalfingermotionmeasurementsystemofathumbandanindexfingerwithoutacalibrationprocess AT baejoonbum athreedimensionalfingermotionmeasurementsystemofathumbandanindexfingerwithoutacalibrationprocess AT parkyeongyu threedimensionalfingermotionmeasurementsystemofathumbandanindexfingerwithoutacalibrationprocess AT baejoonbum threedimensionalfingermotionmeasurementsystemofathumbandanindexfingerwithoutacalibrationprocess |