Cargando…

Computationally Efficient System Matrix Calculation Techniques in Computed Tomography Iterative Reconstruction

BACKGROUND: Relative to classical methods in computed tomography, iterative reconstruction techniques enable significantly improved image qualities and/or lowered patient doses. However, the computational speed is a major concern for these iterative techniques. In the present study, we present a met...

Descripción completa

Detalles Bibliográficos
Autores principales: Mahmoudi, Golshan, Ay, Mohammad Reza, Rahmim, Arman, Ghadiri, Hossein
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7038747/
https://www.ncbi.nlm.nih.gov/pubmed/32166072
http://dx.doi.org/10.4103/jmss.JMSS_29_19
_version_ 1783500705593556992
author Mahmoudi, Golshan
Ay, Mohammad Reza
Rahmim, Arman
Ghadiri, Hossein
author_facet Mahmoudi, Golshan
Ay, Mohammad Reza
Rahmim, Arman
Ghadiri, Hossein
author_sort Mahmoudi, Golshan
collection PubMed
description BACKGROUND: Relative to classical methods in computed tomography, iterative reconstruction techniques enable significantly improved image qualities and/or lowered patient doses. However, the computational speed is a major concern for these iterative techniques. In the present study, we present a method for fast system matrix calculation based on the line integral model (LIM) to speed up the computations without compromising the image quality. In addition, we develop a hybrid line–area integral model (AIM) that highlights the advantages of both LIM and AIMs. METHODS: The contributing detectors for a given pixel and a given projection view, and the length of corresponding intersection lines with pixels, are calculated using our proposed algorithm. For the hybrid method, the respective narrow-angle fan beam was modeled by multiple equally spaced lines. The computed system matrix was evaluated in the context of reconstruction using the simultaneous algebraic reconstruction technique (SART) as well as maximum likelihood expectation maximization (MLEM). RESULTS: The proposed LIM offers a considerable reduction in calculation times compared to the standard Siddon algorithm: 2.9 times faster. Differences in root mean square error and peak signal-to-noise ratio were not significant between the proposed LIM and the Siddon algorithm for both SART and MLEM reconstruction methods (P > 0.05). Meanwhile, the proposed hybrid method resulted in significantly improved image qualities relative to LIM and the Siddon algorithm (P < 0.05), though computations were 4.9 times more intensive than the proposed LIM. CONCLUSION: We have proposed two fast algorithms to calculate the system matrix. The first is based on LIM and was faster than the Siddon algorithm, with matched image quality, whereas the second method is a hybrid LIM–AIM that achieves significantly improved images though with its computational requirements.
format Online
Article
Text
id pubmed-7038747
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-70387472020-03-12 Computationally Efficient System Matrix Calculation Techniques in Computed Tomography Iterative Reconstruction Mahmoudi, Golshan Ay, Mohammad Reza Rahmim, Arman Ghadiri, Hossein J Med Signals Sens Original Article BACKGROUND: Relative to classical methods in computed tomography, iterative reconstruction techniques enable significantly improved image qualities and/or lowered patient doses. However, the computational speed is a major concern for these iterative techniques. In the present study, we present a method for fast system matrix calculation based on the line integral model (LIM) to speed up the computations without compromising the image quality. In addition, we develop a hybrid line–area integral model (AIM) that highlights the advantages of both LIM and AIMs. METHODS: The contributing detectors for a given pixel and a given projection view, and the length of corresponding intersection lines with pixels, are calculated using our proposed algorithm. For the hybrid method, the respective narrow-angle fan beam was modeled by multiple equally spaced lines. The computed system matrix was evaluated in the context of reconstruction using the simultaneous algebraic reconstruction technique (SART) as well as maximum likelihood expectation maximization (MLEM). RESULTS: The proposed LIM offers a considerable reduction in calculation times compared to the standard Siddon algorithm: 2.9 times faster. Differences in root mean square error and peak signal-to-noise ratio were not significant between the proposed LIM and the Siddon algorithm for both SART and MLEM reconstruction methods (P > 0.05). Meanwhile, the proposed hybrid method resulted in significantly improved image qualities relative to LIM and the Siddon algorithm (P < 0.05), though computations were 4.9 times more intensive than the proposed LIM. CONCLUSION: We have proposed two fast algorithms to calculate the system matrix. The first is based on LIM and was faster than the Siddon algorithm, with matched image quality, whereas the second method is a hybrid LIM–AIM that achieves significantly improved images though with its computational requirements. Wolters Kluwer - Medknow 2020-02-06 /pmc/articles/PMC7038747/ /pubmed/32166072 http://dx.doi.org/10.4103/jmss.JMSS_29_19 Text en Copyright: © 2020 Journal of Medical Signals & Sensors http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Mahmoudi, Golshan
Ay, Mohammad Reza
Rahmim, Arman
Ghadiri, Hossein
Computationally Efficient System Matrix Calculation Techniques in Computed Tomography Iterative Reconstruction
title Computationally Efficient System Matrix Calculation Techniques in Computed Tomography Iterative Reconstruction
title_full Computationally Efficient System Matrix Calculation Techniques in Computed Tomography Iterative Reconstruction
title_fullStr Computationally Efficient System Matrix Calculation Techniques in Computed Tomography Iterative Reconstruction
title_full_unstemmed Computationally Efficient System Matrix Calculation Techniques in Computed Tomography Iterative Reconstruction
title_short Computationally Efficient System Matrix Calculation Techniques in Computed Tomography Iterative Reconstruction
title_sort computationally efficient system matrix calculation techniques in computed tomography iterative reconstruction
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7038747/
https://www.ncbi.nlm.nih.gov/pubmed/32166072
http://dx.doi.org/10.4103/jmss.JMSS_29_19
work_keys_str_mv AT mahmoudigolshan computationallyefficientsystemmatrixcalculationtechniquesincomputedtomographyiterativereconstruction
AT aymohammadreza computationallyefficientsystemmatrixcalculationtechniquesincomputedtomographyiterativereconstruction
AT rahmimarman computationallyefficientsystemmatrixcalculationtechniquesincomputedtomographyiterativereconstruction
AT ghadirihossein computationallyefficientsystemmatrixcalculationtechniquesincomputedtomographyiterativereconstruction