Lower Limb Kinematics Using Inertial Sensors during Locomotion: Accuracy and Reproducibility of Joint Angle Calculations with Different Sensor-to-Segment Calibrations

Inertial measurement unit (IMU) records of human movement can be converted into joint angles using a sensor-to-segment calibration, also called functional calibration. This study aims to compare the accuracy and reproducibility of four functional calibration procedures for the 3D tracking of the low...

Descripción completa

Detalles Bibliográficos
Autores principales: Lebleu, Julien, Gosseye, Thierry, Detrembleur, Christine, Mahaudens, Philippe, Cartiaux, Olivier, Penta, Massimo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7039222/
https://www.ncbi.nlm.nih.gov/pubmed/32012906
http://dx.doi.org/10.3390/s20030715
_version_ 1783500783372730368
author Lebleu, Julien
Gosseye, Thierry
Detrembleur, Christine
Mahaudens, Philippe
Cartiaux, Olivier
Penta, Massimo
author_facet Lebleu, Julien
Gosseye, Thierry
Detrembleur, Christine
Mahaudens, Philippe
Cartiaux, Olivier
Penta, Massimo
author_sort Lebleu, Julien
collection PubMed
description Inertial measurement unit (IMU) records of human movement can be converted into joint angles using a sensor-to-segment calibration, also called functional calibration. This study aims to compare the accuracy and reproducibility of four functional calibration procedures for the 3D tracking of the lower limb joint angles of young healthy individuals in gait. Three methods based on segment rotations and one on segment accelerations were used to compare IMU records with an optical system for their accuracy and reproducibility. The squat functional calibration movement, offering a low range of motion of the shank, provided the least accurate measurements. A comparable accuracy was obtained in other methods with a root mean square error below 3.6° and an absolute difference in amplitude below 3.4°. The reproducibility was excellent in the sagittal plane (intra-class correlation coefficient (ICC) > 0.91, standard error of measurement (SEM) < 1.1°), good to excellent in the transverse plane (ICC > 0.87, SEM < 1.1°), and good in the frontal plane (ICC > 0.63, SEM < 1.2°). The better accuracy for proximal joints in calibration movements using segment rotations was traded to distal joints in calibration movements using segment accelerations. These results encourage further applications of IMU systems in unconstrained rehabilitative contexts.
format Online
Article
Text
id pubmed-7039222
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-70392222020-03-09 Lower Limb Kinematics Using Inertial Sensors during Locomotion: Accuracy and Reproducibility of Joint Angle Calculations with Different Sensor-to-Segment Calibrations Lebleu, Julien Gosseye, Thierry Detrembleur, Christine Mahaudens, Philippe Cartiaux, Olivier Penta, Massimo Sensors (Basel) Article Inertial measurement unit (IMU) records of human movement can be converted into joint angles using a sensor-to-segment calibration, also called functional calibration. This study aims to compare the accuracy and reproducibility of four functional calibration procedures for the 3D tracking of the lower limb joint angles of young healthy individuals in gait. Three methods based on segment rotations and one on segment accelerations were used to compare IMU records with an optical system for their accuracy and reproducibility. The squat functional calibration movement, offering a low range of motion of the shank, provided the least accurate measurements. A comparable accuracy was obtained in other methods with a root mean square error below 3.6° and an absolute difference in amplitude below 3.4°. The reproducibility was excellent in the sagittal plane (intra-class correlation coefficient (ICC) > 0.91, standard error of measurement (SEM) < 1.1°), good to excellent in the transverse plane (ICC > 0.87, SEM < 1.1°), and good in the frontal plane (ICC > 0.63, SEM < 1.2°). The better accuracy for proximal joints in calibration movements using segment rotations was traded to distal joints in calibration movements using segment accelerations. These results encourage further applications of IMU systems in unconstrained rehabilitative contexts. MDPI 2020-01-28 /pmc/articles/PMC7039222/ /pubmed/32012906 http://dx.doi.org/10.3390/s20030715 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lebleu, Julien
Gosseye, Thierry
Detrembleur, Christine
Mahaudens, Philippe
Cartiaux, Olivier
Penta, Massimo
Lower Limb Kinematics Using Inertial Sensors during Locomotion: Accuracy and Reproducibility of Joint Angle Calculations with Different Sensor-to-Segment Calibrations
title Lower Limb Kinematics Using Inertial Sensors during Locomotion: Accuracy and Reproducibility of Joint Angle Calculations with Different Sensor-to-Segment Calibrations
title_full Lower Limb Kinematics Using Inertial Sensors during Locomotion: Accuracy and Reproducibility of Joint Angle Calculations with Different Sensor-to-Segment Calibrations
title_fullStr Lower Limb Kinematics Using Inertial Sensors during Locomotion: Accuracy and Reproducibility of Joint Angle Calculations with Different Sensor-to-Segment Calibrations
title_full_unstemmed Lower Limb Kinematics Using Inertial Sensors during Locomotion: Accuracy and Reproducibility of Joint Angle Calculations with Different Sensor-to-Segment Calibrations
title_short Lower Limb Kinematics Using Inertial Sensors during Locomotion: Accuracy and Reproducibility of Joint Angle Calculations with Different Sensor-to-Segment Calibrations
title_sort lower limb kinematics using inertial sensors during locomotion: accuracy and reproducibility of joint angle calculations with different sensor-to-segment calibrations
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7039222/
https://www.ncbi.nlm.nih.gov/pubmed/32012906
http://dx.doi.org/10.3390/s20030715
work_keys_str_mv AT lebleujulien lowerlimbkinematicsusinginertialsensorsduringlocomotionaccuracyandreproducibilityofjointanglecalculationswithdifferentsensortosegmentcalibrations
AT gosseyethierry lowerlimbkinematicsusinginertialsensorsduringlocomotionaccuracyandreproducibilityofjointanglecalculationswithdifferentsensortosegmentcalibrations
AT detrembleurchristine lowerlimbkinematicsusinginertialsensorsduringlocomotionaccuracyandreproducibilityofjointanglecalculationswithdifferentsensortosegmentcalibrations
AT mahaudensphilippe lowerlimbkinematicsusinginertialsensorsduringlocomotionaccuracyandreproducibilityofjointanglecalculationswithdifferentsensortosegmentcalibrations
AT cartiauxolivier lowerlimbkinematicsusinginertialsensorsduringlocomotionaccuracyandreproducibilityofjointanglecalculationswithdifferentsensortosegmentcalibrations
AT pentamassimo lowerlimbkinematicsusinginertialsensorsduringlocomotionaccuracyandreproducibilityofjointanglecalculationswithdifferentsensortosegmentcalibrations