Cargando…

A pre-test post-test assessment of non-invasive keratograph break up time and corneal epithelial thickness after vaping

BACKGROUND: The effects of electronic cigarettes on the ocular surface has yet to be shown. The purpose of the study was to assess the impact of e-cigarette use on the anterior corneal surface integrity. METHODS: Forty three males and 21 females with an average of 21years were required to vape 0.05m...

Descripción completa

Detalles Bibliográficos
Autores principales: Munsamy, Alvin, Bhanprakash, Bhavna, Sirkhot, Amina, Mlambo, Lufun, Dlamuka, Samukelisiwe, Mhlongo, Ndumiso, Naidoo, Ronelle
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Makerere Medical School 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7040307/
https://www.ncbi.nlm.nih.gov/pubmed/32127867
http://dx.doi.org/10.4314/ahs.v19i4.13
_version_ 1783500958968315904
author Munsamy, Alvin
Bhanprakash, Bhavna
Sirkhot, Amina
Mlambo, Lufun
Dlamuka, Samukelisiwe
Mhlongo, Ndumiso
Naidoo, Ronelle
author_facet Munsamy, Alvin
Bhanprakash, Bhavna
Sirkhot, Amina
Mlambo, Lufun
Dlamuka, Samukelisiwe
Mhlongo, Ndumiso
Naidoo, Ronelle
author_sort Munsamy, Alvin
collection PubMed
description BACKGROUND: The effects of electronic cigarettes on the ocular surface has yet to be shown. The purpose of the study was to assess the impact of e-cigarette use on the anterior corneal surface integrity. METHODS: Forty three males and 21 females with an average of 21years were required to vape 0.05ml of e-liquid of 8mg nicotine concentration. Corneal epithelial thickness (CET) and Non Invasive Keratograph Tear Break up Time (NIKBUT) measurements were obtained prior to and post vaping. The Optovue iVue optical coherence topographer was used to measure central; superior; inferior; nasal and temporal CET and NIKBUT was assessed using the Oculus Keratograph 5M. RESULTS: There was a mean increase for central corneal epithelial thickness of 0.3448 microns. The superior CET increased by 0.2414 microns. The inferior CET increased by 0.2931microns. The nasal CET increased by 0.2069 microns. The temporal CET increased by 0.2759 microns. The mean change in NIKBUT post-vaping was an increase of 1.40 seconds. All observations occurred at p > 0.05. CONCLUSION: The acute effect of e-cigarette use does not impact corneal epithelial thickness and non-invasive keratography tear break up time after 10 puffs mild exposure but more research is needed to assess if this remains the case with more frequent, higher exposure.
format Online
Article
Text
id pubmed-7040307
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Makerere Medical School
record_format MEDLINE/PubMed
spelling pubmed-70403072020-03-03 A pre-test post-test assessment of non-invasive keratograph break up time and corneal epithelial thickness after vaping Munsamy, Alvin Bhanprakash, Bhavna Sirkhot, Amina Mlambo, Lufun Dlamuka, Samukelisiwe Mhlongo, Ndumiso Naidoo, Ronelle Afr Health Sci Articles BACKGROUND: The effects of electronic cigarettes on the ocular surface has yet to be shown. The purpose of the study was to assess the impact of e-cigarette use on the anterior corneal surface integrity. METHODS: Forty three males and 21 females with an average of 21years were required to vape 0.05ml of e-liquid of 8mg nicotine concentration. Corneal epithelial thickness (CET) and Non Invasive Keratograph Tear Break up Time (NIKBUT) measurements were obtained prior to and post vaping. The Optovue iVue optical coherence topographer was used to measure central; superior; inferior; nasal and temporal CET and NIKBUT was assessed using the Oculus Keratograph 5M. RESULTS: There was a mean increase for central corneal epithelial thickness of 0.3448 microns. The superior CET increased by 0.2414 microns. The inferior CET increased by 0.2931microns. The nasal CET increased by 0.2069 microns. The temporal CET increased by 0.2759 microns. The mean change in NIKBUT post-vaping was an increase of 1.40 seconds. All observations occurred at p > 0.05. CONCLUSION: The acute effect of e-cigarette use does not impact corneal epithelial thickness and non-invasive keratography tear break up time after 10 puffs mild exposure but more research is needed to assess if this remains the case with more frequent, higher exposure. Makerere Medical School 2019-12 /pmc/articles/PMC7040307/ /pubmed/32127867 http://dx.doi.org/10.4314/ahs.v19i4.13 Text en © 2019 Munsamy et al. Licensee African Health Sciences. This is an Open Access article distributed under the terms of the Creative commons Attribution License (https://creativecommons.org/licenses/BY/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Articles
Munsamy, Alvin
Bhanprakash, Bhavna
Sirkhot, Amina
Mlambo, Lufun
Dlamuka, Samukelisiwe
Mhlongo, Ndumiso
Naidoo, Ronelle
A pre-test post-test assessment of non-invasive keratograph break up time and corneal epithelial thickness after vaping
title A pre-test post-test assessment of non-invasive keratograph break up time and corneal epithelial thickness after vaping
title_full A pre-test post-test assessment of non-invasive keratograph break up time and corneal epithelial thickness after vaping
title_fullStr A pre-test post-test assessment of non-invasive keratograph break up time and corneal epithelial thickness after vaping
title_full_unstemmed A pre-test post-test assessment of non-invasive keratograph break up time and corneal epithelial thickness after vaping
title_short A pre-test post-test assessment of non-invasive keratograph break up time and corneal epithelial thickness after vaping
title_sort pre-test post-test assessment of non-invasive keratograph break up time and corneal epithelial thickness after vaping
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7040307/
https://www.ncbi.nlm.nih.gov/pubmed/32127867
http://dx.doi.org/10.4314/ahs.v19i4.13
work_keys_str_mv AT munsamyalvin apretestposttestassessmentofnoninvasivekeratographbreakuptimeandcornealepithelialthicknessaftervaping
AT bhanprakashbhavna apretestposttestassessmentofnoninvasivekeratographbreakuptimeandcornealepithelialthicknessaftervaping
AT sirkhotamina apretestposttestassessmentofnoninvasivekeratographbreakuptimeandcornealepithelialthicknessaftervaping
AT mlambolufun apretestposttestassessmentofnoninvasivekeratographbreakuptimeandcornealepithelialthicknessaftervaping
AT dlamukasamukelisiwe apretestposttestassessmentofnoninvasivekeratographbreakuptimeandcornealepithelialthicknessaftervaping
AT mhlongondumiso apretestposttestassessmentofnoninvasivekeratographbreakuptimeandcornealepithelialthicknessaftervaping
AT naidooronelle apretestposttestassessmentofnoninvasivekeratographbreakuptimeandcornealepithelialthicknessaftervaping
AT munsamyalvin pretestposttestassessmentofnoninvasivekeratographbreakuptimeandcornealepithelialthicknessaftervaping
AT bhanprakashbhavna pretestposttestassessmentofnoninvasivekeratographbreakuptimeandcornealepithelialthicknessaftervaping
AT sirkhotamina pretestposttestassessmentofnoninvasivekeratographbreakuptimeandcornealepithelialthicknessaftervaping
AT mlambolufun pretestposttestassessmentofnoninvasivekeratographbreakuptimeandcornealepithelialthicknessaftervaping
AT dlamukasamukelisiwe pretestposttestassessmentofnoninvasivekeratographbreakuptimeandcornealepithelialthicknessaftervaping
AT mhlongondumiso pretestposttestassessmentofnoninvasivekeratographbreakuptimeandcornealepithelialthicknessaftervaping
AT naidooronelle pretestposttestassessmentofnoninvasivekeratographbreakuptimeandcornealepithelialthicknessaftervaping