Cargando…

Influence of zirconia and lithium disilicate tooth- or implant-supported crowns on wear of antagonistic and adjacent teeth

PURPOSE: To investigate the influence of crown material (lithium-disilicate, 3Y-TZP zirconia) and abutment type (rigid implant, resin tooth with artificial periodontium) on wear performance of their antagonist teeth and adjacent teeth. MATERIALS AND METHODS: A mandibular left first molar (#36) with...

Descripción completa

Detalles Bibliográficos
Autores principales: Rosentritt, Martin, Schumann, Frederik, Krifka, Stephanie, Preis, Verena
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Prosthodontics 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7040450/
https://www.ncbi.nlm.nih.gov/pubmed/32128080
http://dx.doi.org/10.4047/jap.2020.12.1.1
_version_ 1783500991408111616
author Rosentritt, Martin
Schumann, Frederik
Krifka, Stephanie
Preis, Verena
author_facet Rosentritt, Martin
Schumann, Frederik
Krifka, Stephanie
Preis, Verena
author_sort Rosentritt, Martin
collection PubMed
description PURPOSE: To investigate the influence of crown material (lithium-disilicate, 3Y-TZP zirconia) and abutment type (rigid implant, resin tooth with artificial periodontium) on wear performance of their antagonist teeth and adjacent teeth. MATERIALS AND METHODS: A mandibular left first molar (#36) with adjacent human teeth (mandibular left second premolar: #35, mandibular left second molar: #37) and antagonistic human teeth (maxillary left second premolar: #25, maxillary left first molar: #26, maxillary left second molar: #27) was prepared simulating a section of the jaw. Samples were made with extracted human molars (Reference), crowned implants (Implant), or crowned resin tooth analogues (Tooth). Crowns (tooth #36; n = 16/material) were milled from lithium-disilicate (Li, IPS e.max CAD) or 3Y-TZP zirconia (Zr, IPS e.max ZirCAD, both Ivoclar Vivadent). Thermal cycling and mechanical loading (TCML) in the chewing simulator were applied simulating 15 years of clinical service. Wear traces were analyzed (frequency [n], depth [µm]) and evaluated using scanning electron pictures. Wear results were compared by one-way-ANOVA and post-hoc-Bonferroni (α = 0.05). RESULTS: After TCML, no visible wear traces were found on Zr. Li showed more wear traces (n = 30–31) than the reference (n = 21). Antagonistic teeth #26 showed more wear traces in contact to both ceramics (n = 27–29) than to the reference (n = 21). Strong wear traces (> 350 µm) on antagonists and their adjacent teeth were found only in crowned groups. Abutment type influenced number and depth of wear facets on the antagonistic and adjacent teeth. CONCLUSION: The clinically relevant model with human antagonistic and adjacent teeth allowed for a limited comparison of the wear situation. The total number of wear traces and strong wear on crowns, antagonistic and adjacent teeth were influenced by crown material.
format Online
Article
Text
id pubmed-7040450
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The Korean Academy of Prosthodontics
record_format MEDLINE/PubMed
spelling pubmed-70404502020-03-03 Influence of zirconia and lithium disilicate tooth- or implant-supported crowns on wear of antagonistic and adjacent teeth Rosentritt, Martin Schumann, Frederik Krifka, Stephanie Preis, Verena J Adv Prosthodont Original Article PURPOSE: To investigate the influence of crown material (lithium-disilicate, 3Y-TZP zirconia) and abutment type (rigid implant, resin tooth with artificial periodontium) on wear performance of their antagonist teeth and adjacent teeth. MATERIALS AND METHODS: A mandibular left first molar (#36) with adjacent human teeth (mandibular left second premolar: #35, mandibular left second molar: #37) and antagonistic human teeth (maxillary left second premolar: #25, maxillary left first molar: #26, maxillary left second molar: #27) was prepared simulating a section of the jaw. Samples were made with extracted human molars (Reference), crowned implants (Implant), or crowned resin tooth analogues (Tooth). Crowns (tooth #36; n = 16/material) were milled from lithium-disilicate (Li, IPS e.max CAD) or 3Y-TZP zirconia (Zr, IPS e.max ZirCAD, both Ivoclar Vivadent). Thermal cycling and mechanical loading (TCML) in the chewing simulator were applied simulating 15 years of clinical service. Wear traces were analyzed (frequency [n], depth [µm]) and evaluated using scanning electron pictures. Wear results were compared by one-way-ANOVA and post-hoc-Bonferroni (α = 0.05). RESULTS: After TCML, no visible wear traces were found on Zr. Li showed more wear traces (n = 30–31) than the reference (n = 21). Antagonistic teeth #26 showed more wear traces in contact to both ceramics (n = 27–29) than to the reference (n = 21). Strong wear traces (> 350 µm) on antagonists and their adjacent teeth were found only in crowned groups. Abutment type influenced number and depth of wear facets on the antagonistic and adjacent teeth. CONCLUSION: The clinically relevant model with human antagonistic and adjacent teeth allowed for a limited comparison of the wear situation. The total number of wear traces and strong wear on crowns, antagonistic and adjacent teeth were influenced by crown material. The Korean Academy of Prosthodontics 2020-02 2020-02-20 /pmc/articles/PMC7040450/ /pubmed/32128080 http://dx.doi.org/10.4047/jap.2020.12.1.1 Text en © 2020 The Korean Academy of Prosthodontics http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Rosentritt, Martin
Schumann, Frederik
Krifka, Stephanie
Preis, Verena
Influence of zirconia and lithium disilicate tooth- or implant-supported crowns on wear of antagonistic and adjacent teeth
title Influence of zirconia and lithium disilicate tooth- or implant-supported crowns on wear of antagonistic and adjacent teeth
title_full Influence of zirconia and lithium disilicate tooth- or implant-supported crowns on wear of antagonistic and adjacent teeth
title_fullStr Influence of zirconia and lithium disilicate tooth- or implant-supported crowns on wear of antagonistic and adjacent teeth
title_full_unstemmed Influence of zirconia and lithium disilicate tooth- or implant-supported crowns on wear of antagonistic and adjacent teeth
title_short Influence of zirconia and lithium disilicate tooth- or implant-supported crowns on wear of antagonistic and adjacent teeth
title_sort influence of zirconia and lithium disilicate tooth- or implant-supported crowns on wear of antagonistic and adjacent teeth
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7040450/
https://www.ncbi.nlm.nih.gov/pubmed/32128080
http://dx.doi.org/10.4047/jap.2020.12.1.1
work_keys_str_mv AT rosentrittmartin influenceofzirconiaandlithiumdisilicatetoothorimplantsupportedcrownsonwearofantagonisticandadjacentteeth
AT schumannfrederik influenceofzirconiaandlithiumdisilicatetoothorimplantsupportedcrownsonwearofantagonisticandadjacentteeth
AT krifkastephanie influenceofzirconiaandlithiumdisilicatetoothorimplantsupportedcrownsonwearofantagonisticandadjacentteeth
AT preisverena influenceofzirconiaandlithiumdisilicatetoothorimplantsupportedcrownsonwearofantagonisticandadjacentteeth