Cargando…

TGV-regularized inversion of the Radon transform for photoacoustic tomography

We propose and study a reconstruction method for photoacoustic tomography (PAT) based on total generalized variation (TGV) regularization for the inversion of the slice-wise 2D-Radon transform in 3D. The latter problem occurs for recently-developed PAT imaging techniques with parallelized integratin...

Descripción completa

Detalles Bibliográficos
Autores principales: Bredies, Kristian, Nuster, Robert, Watschinger, Raphael
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Optical Society of America 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7041474/
https://www.ncbi.nlm.nih.gov/pubmed/32133234
http://dx.doi.org/10.1364/BOE.379941
_version_ 1783501160115601408
author Bredies, Kristian
Nuster, Robert
Watschinger, Raphael
author_facet Bredies, Kristian
Nuster, Robert
Watschinger, Raphael
author_sort Bredies, Kristian
collection PubMed
description We propose and study a reconstruction method for photoacoustic tomography (PAT) based on total generalized variation (TGV) regularization for the inversion of the slice-wise 2D-Radon transform in 3D. The latter problem occurs for recently-developed PAT imaging techniques with parallelized integrating ultrasound detection where projection data from various directions is sequentially acquired. As the imaging speed is presently limited to 20 seconds per 3D image, the reconstruction of temporally-resolved 3D sequences of, e.g., one heartbeat or breathing cycle, is very challenging and currently, the presence of motion artifacts in the reconstructions obstructs the applicability for biomedical research. In order to push these techniques forward towards real time, it thus becomes necessary to reconstruct from less measured data such as few-projection data and consequently, to employ sophisticated reconstruction methods in order to avoid typical artifacts. The proposed TGV-regularized Radon inversion is a variational method that is shown to be capable of such artifact-free inversion. It is validated by numerical simulations, compared to filtered back projection (FBP), and performance-tested on real data from phantom as well as in-vivo mouse experiments. The results indicate that a speed-up factor of four is possible without compromising reconstruction quality.
format Online
Article
Text
id pubmed-7041474
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Optical Society of America
record_format MEDLINE/PubMed
spelling pubmed-70414742020-03-04 TGV-regularized inversion of the Radon transform for photoacoustic tomography Bredies, Kristian Nuster, Robert Watschinger, Raphael Biomed Opt Express Article We propose and study a reconstruction method for photoacoustic tomography (PAT) based on total generalized variation (TGV) regularization for the inversion of the slice-wise 2D-Radon transform in 3D. The latter problem occurs for recently-developed PAT imaging techniques with parallelized integrating ultrasound detection where projection data from various directions is sequentially acquired. As the imaging speed is presently limited to 20 seconds per 3D image, the reconstruction of temporally-resolved 3D sequences of, e.g., one heartbeat or breathing cycle, is very challenging and currently, the presence of motion artifacts in the reconstructions obstructs the applicability for biomedical research. In order to push these techniques forward towards real time, it thus becomes necessary to reconstruct from less measured data such as few-projection data and consequently, to employ sophisticated reconstruction methods in order to avoid typical artifacts. The proposed TGV-regularized Radon inversion is a variational method that is shown to be capable of such artifact-free inversion. It is validated by numerical simulations, compared to filtered back projection (FBP), and performance-tested on real data from phantom as well as in-vivo mouse experiments. The results indicate that a speed-up factor of four is possible without compromising reconstruction quality. Optical Society of America 2020-01-22 /pmc/articles/PMC7041474/ /pubmed/32133234 http://dx.doi.org/10.1364/BOE.379941 Text en Published by The Optical Society under the terms of the Creative Commons Attribution 4.0 License. Further distribution of this work must maintain attribution to the author(s) and the published article’s title, journal citation, and DOI. Published by The Optical Society under the terms of the Creative Commons Attribution 4.0 License (http://creativecommons.org/licenses/by/4.0/) . Further distribution of this work must maintain attribution to the author(s) and the published article’s title, journal citation, and DOI.
spellingShingle Article
Bredies, Kristian
Nuster, Robert
Watschinger, Raphael
TGV-regularized inversion of the Radon transform for photoacoustic tomography
title TGV-regularized inversion of the Radon transform for photoacoustic tomography
title_full TGV-regularized inversion of the Radon transform for photoacoustic tomography
title_fullStr TGV-regularized inversion of the Radon transform for photoacoustic tomography
title_full_unstemmed TGV-regularized inversion of the Radon transform for photoacoustic tomography
title_short TGV-regularized inversion of the Radon transform for photoacoustic tomography
title_sort tgv-regularized inversion of the radon transform for photoacoustic tomography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7041474/
https://www.ncbi.nlm.nih.gov/pubmed/32133234
http://dx.doi.org/10.1364/BOE.379941
work_keys_str_mv AT bredieskristian tgvregularizedinversionoftheradontransformforphotoacoustictomography
AT nusterrobert tgvregularizedinversionoftheradontransformforphotoacoustictomography
AT watschingerraphael tgvregularizedinversionoftheradontransformforphotoacoustictomography