Cargando…
Treatment of severe aortic stenosis and left ventricular outflow tract mass with transcutaneous aortic valve implantation: a case report
BACKGROUND: Percutaneous implantation of aortic valve for severe aortic stenosis (AS) in the presence of pedunculated mobile left ventricular outflow tract (LVOT) mass not reported before. In this case report, we address the feasibility of this procedure. CASE SUMMARY: An 80-year-old patient who pre...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7042132/ https://www.ncbi.nlm.nih.gov/pubmed/32123789 http://dx.doi.org/10.1093/ehjcr/ytz194 |
_version_ | 1783501246407114752 |
---|---|
author | Naeim, Hesham A Saeed, Waleed Alharbi, Ibraheem Abuelatta, Reda |
author_facet | Naeim, Hesham A Saeed, Waleed Alharbi, Ibraheem Abuelatta, Reda |
author_sort | Naeim, Hesham A |
collection | PubMed |
description | BACKGROUND: Percutaneous implantation of aortic valve for severe aortic stenosis (AS) in the presence of pedunculated mobile left ventricular outflow tract (LVOT) mass not reported before. In this case report, we address the feasibility of this procedure. CASE SUMMARY: An 80-year-old patient who presented with presyncope, transthoracic echocardiogram (TTE), and transoesophageal echocardiography (TOE) revealed severe calcific AS and LVOT mass measuring 2.1*1.5 cm. The patient was turned down for surgery. It was decided that transcatheter aortic valve implantation (TAVI) be performed because the valve compresses the mass against the proximal part of the interventricular septum. The mass peduncle was 1.4 cm, and it was 4 mm away from the annulus. This meant the valve was needed to be deployed 18 mm below the annulus to cover the mass completely. Gentle manipulation and direct valve deployment without preballoon dilation to decrease the possibility of fragment embolization were necessary. Self-expandable core valve deployed as low as possible, after initial deployment, the distance of LVOT covered by the valve measured by TOE 1.66 cm, the whole mass was covered, then the valve was fully deployed. The patient was extubated in the catheterization room; there was no clinical evidence of embolization. The patient was discharged home after 2 days. A follow-up TTE after 6 months showed a well-functioning valve and the LVOT mass then disappeared. DISCUSSION: Pedunculated LVOT mass should be resected surgically. In high-risk surgical patients, direct TAVI to compress the mass is feasible in experienced canters. The safety issues need more research and more cases to judge. Transoesophageal echocardiography during the procedure is mandatory to guide the valve position. |
format | Online Article Text |
id | pubmed-7042132 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-70421322020-03-02 Treatment of severe aortic stenosis and left ventricular outflow tract mass with transcutaneous aortic valve implantation: a case report Naeim, Hesham A Saeed, Waleed Alharbi, Ibraheem Abuelatta, Reda Eur Heart J Case Rep Case Reports BACKGROUND: Percutaneous implantation of aortic valve for severe aortic stenosis (AS) in the presence of pedunculated mobile left ventricular outflow tract (LVOT) mass not reported before. In this case report, we address the feasibility of this procedure. CASE SUMMARY: An 80-year-old patient who presented with presyncope, transthoracic echocardiogram (TTE), and transoesophageal echocardiography (TOE) revealed severe calcific AS and LVOT mass measuring 2.1*1.5 cm. The patient was turned down for surgery. It was decided that transcatheter aortic valve implantation (TAVI) be performed because the valve compresses the mass against the proximal part of the interventricular septum. The mass peduncle was 1.4 cm, and it was 4 mm away from the annulus. This meant the valve was needed to be deployed 18 mm below the annulus to cover the mass completely. Gentle manipulation and direct valve deployment without preballoon dilation to decrease the possibility of fragment embolization were necessary. Self-expandable core valve deployed as low as possible, after initial deployment, the distance of LVOT covered by the valve measured by TOE 1.66 cm, the whole mass was covered, then the valve was fully deployed. The patient was extubated in the catheterization room; there was no clinical evidence of embolization. The patient was discharged home after 2 days. A follow-up TTE after 6 months showed a well-functioning valve and the LVOT mass then disappeared. DISCUSSION: Pedunculated LVOT mass should be resected surgically. In high-risk surgical patients, direct TAVI to compress the mass is feasible in experienced canters. The safety issues need more research and more cases to judge. Transoesophageal echocardiography during the procedure is mandatory to guide the valve position. Oxford University Press 2019-10-24 /pmc/articles/PMC7042132/ /pubmed/32123789 http://dx.doi.org/10.1093/ehjcr/ytz194 Text en © The Author(s) 2019. Published by Oxford University Press on behalf of the European Society of Cardiology. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Case Reports Naeim, Hesham A Saeed, Waleed Alharbi, Ibraheem Abuelatta, Reda Treatment of severe aortic stenosis and left ventricular outflow tract mass with transcutaneous aortic valve implantation: a case report |
title | Treatment of severe aortic stenosis and left ventricular outflow tract mass with transcutaneous aortic valve implantation: a case report |
title_full | Treatment of severe aortic stenosis and left ventricular outflow tract mass with transcutaneous aortic valve implantation: a case report |
title_fullStr | Treatment of severe aortic stenosis and left ventricular outflow tract mass with transcutaneous aortic valve implantation: a case report |
title_full_unstemmed | Treatment of severe aortic stenosis and left ventricular outflow tract mass with transcutaneous aortic valve implantation: a case report |
title_short | Treatment of severe aortic stenosis and left ventricular outflow tract mass with transcutaneous aortic valve implantation: a case report |
title_sort | treatment of severe aortic stenosis and left ventricular outflow tract mass with transcutaneous aortic valve implantation: a case report |
topic | Case Reports |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7042132/ https://www.ncbi.nlm.nih.gov/pubmed/32123789 http://dx.doi.org/10.1093/ehjcr/ytz194 |
work_keys_str_mv | AT naeimheshama treatmentofsevereaorticstenosisandleftventricularoutflowtractmasswithtranscutaneousaorticvalveimplantationacasereport AT saeedwaleed treatmentofsevereaorticstenosisandleftventricularoutflowtractmasswithtranscutaneousaorticvalveimplantationacasereport AT alharbiibraheem treatmentofsevereaorticstenosisandleftventricularoutflowtractmasswithtranscutaneousaorticvalveimplantationacasereport AT abuelattareda treatmentofsevereaorticstenosisandleftventricularoutflowtractmasswithtranscutaneousaorticvalveimplantationacasereport |