Precise MEP monitoring with a reduced interval is safe and useful for detecting permissive duration for temporary clipping
Although temporary clipping of the parent artery is an indispensable technique in clipping surgery for intracranial aneurysms, the permissive duration of temporary clipping is still not well known. The aim of this study is to confirm the safety of precise motor evoked potential (MEP) monitoring and...
Autores principales: | Kameda, Masahiro, Hishikawa, Tomohito, Hiramatsu, Masafumi, Yasuhara, Takao, Kurozumi, Kazuhiko, Date, Isao |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7044220/ https://www.ncbi.nlm.nih.gov/pubmed/32103082 http://dx.doi.org/10.1038/s41598-020-60377-9 |
Ejemplares similares
-
Cerebral circulation improves with indirect bypass surgery combined with gene therapy
por: Shear, Alex, et al.
Publicado: (2019) -
An Evaluation of the Safety and Feasibility of Adenosine-assisted Clipping Surgery for Unruptured Cerebral Aneurysms: Study Protocol
por: HISHIKAWA, Tomohito, et al.
Publicado: (2021) -
SURG-21. ENDO- AND EXOSCOPIC SURGERY FOR PEDIATRIC NEUROSURGICAL OPERATION
por: Kurozumi, Kazuhiko, et al.
Publicado: (2020) -
Combination of the tubular retractor and brain spatulas provides an adequate operative field in surgery for deep-seated lesions: Case series and technical note
por: Otani, Yoshihiro, et al.
Publicado: (2018) -
High-Mobility Group Box-1-Induced Angiogenesis After Indirect Bypass Surgery in a Chronic Cerebral Hypoperfusion Model
por: Nishihiro, Shingo, et al.
Publicado: (2019)