Is four-dimensional CT angiography as effective as digital subtraction angiography in the detection of the underlying causes of intracerebral haemorrhage: a systematic review
PURPOSE: To determine whether the sensitivity and specificity of four-dimensional CTA (4D-CTA) are equivalent to digital subtraction angiography (DSA) in the detection of underlying vascular abnormalities in patients with intracerebral haemorrhage (ICH). METHODS: A systematic review of studies compa...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7044254/ https://www.ncbi.nlm.nih.gov/pubmed/31901972 http://dx.doi.org/10.1007/s00234-019-02349-z |
_version_ | 1783501529915850752 |
---|---|
author | Denby, C. E. Chatterjee, K. Pullicino, R. Lane, S. Radon, M. R. Das, K. V. |
author_facet | Denby, C. E. Chatterjee, K. Pullicino, R. Lane, S. Radon, M. R. Das, K. V. |
author_sort | Denby, C. E. |
collection | PubMed |
description | PURPOSE: To determine whether the sensitivity and specificity of four-dimensional CTA (4D-CTA) are equivalent to digital subtraction angiography (DSA) in the detection of underlying vascular abnormalities in patients with intracerebral haemorrhage (ICH). METHODS: A systematic review of studies comparing 4D-CTA with DSA in the detection of the underlying structural causes of ICH was performed on the literature published between 1998 and 2019. RESULTS: We identified a total of 237 articles from PubMed, SCOPUS and Web of Science using the following Medical Subject Headings (MeSH) terms: primary intracerebral haemorrhage, 4D-CTA, DSA, cerebral haemorrhage, angiography, digital subtraction, arteriovenous malformations, 4D, CTA, dynamic-CTA and time-resolved CTA. Following the removal of duplicate publications and articles failing to meet our inclusion criteria, there were four articles potentially viable for analysis. Therefore, there were not sufficient studies to provide a statistically meaningful meta-analysis. CONCLUSION: The review of current literature has demonstrated that there are few published studies comparing 4D-CTA with DSA in spontaneous ICH, with only four suitable studies identified for potential analysis. However, due to the restricted number of patients and high sensitivity and specificity of 3 studies (100%), performing a meta-analysis was not meaningful. Qualitative analysis of the data concluded that 4D-CTA has the diagnostic potential to replace invasive DSA in certain cases with vascular abnormalities. However, further research studies directly comparing 4D-CTA with DSA using larger prospective patient cohorts are required to strengthen the evidence base. |
format | Online Article Text |
id | pubmed-7044254 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-70442542020-03-10 Is four-dimensional CT angiography as effective as digital subtraction angiography in the detection of the underlying causes of intracerebral haemorrhage: a systematic review Denby, C. E. Chatterjee, K. Pullicino, R. Lane, S. Radon, M. R. Das, K. V. Neuroradiology Review PURPOSE: To determine whether the sensitivity and specificity of four-dimensional CTA (4D-CTA) are equivalent to digital subtraction angiography (DSA) in the detection of underlying vascular abnormalities in patients with intracerebral haemorrhage (ICH). METHODS: A systematic review of studies comparing 4D-CTA with DSA in the detection of the underlying structural causes of ICH was performed on the literature published between 1998 and 2019. RESULTS: We identified a total of 237 articles from PubMed, SCOPUS and Web of Science using the following Medical Subject Headings (MeSH) terms: primary intracerebral haemorrhage, 4D-CTA, DSA, cerebral haemorrhage, angiography, digital subtraction, arteriovenous malformations, 4D, CTA, dynamic-CTA and time-resolved CTA. Following the removal of duplicate publications and articles failing to meet our inclusion criteria, there were four articles potentially viable for analysis. Therefore, there were not sufficient studies to provide a statistically meaningful meta-analysis. CONCLUSION: The review of current literature has demonstrated that there are few published studies comparing 4D-CTA with DSA in spontaneous ICH, with only four suitable studies identified for potential analysis. However, due to the restricted number of patients and high sensitivity and specificity of 3 studies (100%), performing a meta-analysis was not meaningful. Qualitative analysis of the data concluded that 4D-CTA has the diagnostic potential to replace invasive DSA in certain cases with vascular abnormalities. However, further research studies directly comparing 4D-CTA with DSA using larger prospective patient cohorts are required to strengthen the evidence base. Springer Berlin Heidelberg 2020-01-04 2020 /pmc/articles/PMC7044254/ /pubmed/31901972 http://dx.doi.org/10.1007/s00234-019-02349-z Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Review Denby, C. E. Chatterjee, K. Pullicino, R. Lane, S. Radon, M. R. Das, K. V. Is four-dimensional CT angiography as effective as digital subtraction angiography in the detection of the underlying causes of intracerebral haemorrhage: a systematic review |
title | Is four-dimensional CT angiography as effective as digital subtraction angiography in the detection of the underlying causes of intracerebral haemorrhage: a systematic review |
title_full | Is four-dimensional CT angiography as effective as digital subtraction angiography in the detection of the underlying causes of intracerebral haemorrhage: a systematic review |
title_fullStr | Is four-dimensional CT angiography as effective as digital subtraction angiography in the detection of the underlying causes of intracerebral haemorrhage: a systematic review |
title_full_unstemmed | Is four-dimensional CT angiography as effective as digital subtraction angiography in the detection of the underlying causes of intracerebral haemorrhage: a systematic review |
title_short | Is four-dimensional CT angiography as effective as digital subtraction angiography in the detection of the underlying causes of intracerebral haemorrhage: a systematic review |
title_sort | is four-dimensional ct angiography as effective as digital subtraction angiography in the detection of the underlying causes of intracerebral haemorrhage: a systematic review |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7044254/ https://www.ncbi.nlm.nih.gov/pubmed/31901972 http://dx.doi.org/10.1007/s00234-019-02349-z |
work_keys_str_mv | AT denbyce isfourdimensionalctangiographyaseffectiveasdigitalsubtractionangiographyinthedetectionoftheunderlyingcausesofintracerebralhaemorrhageasystematicreview AT chatterjeek isfourdimensionalctangiographyaseffectiveasdigitalsubtractionangiographyinthedetectionoftheunderlyingcausesofintracerebralhaemorrhageasystematicreview AT pullicinor isfourdimensionalctangiographyaseffectiveasdigitalsubtractionangiographyinthedetectionoftheunderlyingcausesofintracerebralhaemorrhageasystematicreview AT lanes isfourdimensionalctangiographyaseffectiveasdigitalsubtractionangiographyinthedetectionoftheunderlyingcausesofintracerebralhaemorrhageasystematicreview AT radonmr isfourdimensionalctangiographyaseffectiveasdigitalsubtractionangiographyinthedetectionoftheunderlyingcausesofintracerebralhaemorrhageasystematicreview AT daskv isfourdimensionalctangiographyaseffectiveasdigitalsubtractionangiographyinthedetectionoftheunderlyingcausesofintracerebralhaemorrhageasystematicreview |