Cargando…

Is four-dimensional CT angiography as effective as digital subtraction angiography in the detection of the underlying causes of intracerebral haemorrhage: a systematic review

PURPOSE: To determine whether the sensitivity and specificity of four-dimensional CTA (4D-CTA) are equivalent to digital subtraction angiography (DSA) in the detection of underlying vascular abnormalities in patients with intracerebral haemorrhage (ICH). METHODS: A systematic review of studies compa...

Descripción completa

Detalles Bibliográficos
Autores principales: Denby, C. E., Chatterjee, K., Pullicino, R., Lane, S., Radon, M. R., Das, K. V.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7044254/
https://www.ncbi.nlm.nih.gov/pubmed/31901972
http://dx.doi.org/10.1007/s00234-019-02349-z
_version_ 1783501529915850752
author Denby, C. E.
Chatterjee, K.
Pullicino, R.
Lane, S.
Radon, M. R.
Das, K. V.
author_facet Denby, C. E.
Chatterjee, K.
Pullicino, R.
Lane, S.
Radon, M. R.
Das, K. V.
author_sort Denby, C. E.
collection PubMed
description PURPOSE: To determine whether the sensitivity and specificity of four-dimensional CTA (4D-CTA) are equivalent to digital subtraction angiography (DSA) in the detection of underlying vascular abnormalities in patients with intracerebral haemorrhage (ICH). METHODS: A systematic review of studies comparing 4D-CTA with DSA in the detection of the underlying structural causes of ICH was performed on the literature published between 1998 and 2019. RESULTS: We identified a total of 237 articles from PubMed, SCOPUS and Web of Science using the following Medical Subject Headings (MeSH) terms: primary intracerebral haemorrhage, 4D-CTA, DSA, cerebral haemorrhage, angiography, digital subtraction, arteriovenous malformations, 4D, CTA, dynamic-CTA and time-resolved CTA. Following the removal of duplicate publications and articles failing to meet our inclusion criteria, there were four articles potentially viable for analysis. Therefore, there were not sufficient studies to provide a statistically meaningful meta-analysis. CONCLUSION: The review of current literature has demonstrated that there are few published studies comparing 4D-CTA with DSA in spontaneous ICH, with only four suitable studies identified for potential analysis. However, due to the restricted number of patients and high sensitivity and specificity of 3 studies (100%), performing a meta-analysis was not meaningful. Qualitative analysis of the data concluded that 4D-CTA has the diagnostic potential to replace invasive DSA in certain cases with vascular abnormalities. However, further research studies directly comparing 4D-CTA with DSA using larger prospective patient cohorts are required to strengthen the evidence base.
format Online
Article
Text
id pubmed-7044254
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-70442542020-03-10 Is four-dimensional CT angiography as effective as digital subtraction angiography in the detection of the underlying causes of intracerebral haemorrhage: a systematic review Denby, C. E. Chatterjee, K. Pullicino, R. Lane, S. Radon, M. R. Das, K. V. Neuroradiology Review PURPOSE: To determine whether the sensitivity and specificity of four-dimensional CTA (4D-CTA) are equivalent to digital subtraction angiography (DSA) in the detection of underlying vascular abnormalities in patients with intracerebral haemorrhage (ICH). METHODS: A systematic review of studies comparing 4D-CTA with DSA in the detection of the underlying structural causes of ICH was performed on the literature published between 1998 and 2019. RESULTS: We identified a total of 237 articles from PubMed, SCOPUS and Web of Science using the following Medical Subject Headings (MeSH) terms: primary intracerebral haemorrhage, 4D-CTA, DSA, cerebral haemorrhage, angiography, digital subtraction, arteriovenous malformations, 4D, CTA, dynamic-CTA and time-resolved CTA. Following the removal of duplicate publications and articles failing to meet our inclusion criteria, there were four articles potentially viable for analysis. Therefore, there were not sufficient studies to provide a statistically meaningful meta-analysis. CONCLUSION: The review of current literature has demonstrated that there are few published studies comparing 4D-CTA with DSA in spontaneous ICH, with only four suitable studies identified for potential analysis. However, due to the restricted number of patients and high sensitivity and specificity of 3 studies (100%), performing a meta-analysis was not meaningful. Qualitative analysis of the data concluded that 4D-CTA has the diagnostic potential to replace invasive DSA in certain cases with vascular abnormalities. However, further research studies directly comparing 4D-CTA with DSA using larger prospective patient cohorts are required to strengthen the evidence base. Springer Berlin Heidelberg 2020-01-04 2020 /pmc/articles/PMC7044254/ /pubmed/31901972 http://dx.doi.org/10.1007/s00234-019-02349-z Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Review
Denby, C. E.
Chatterjee, K.
Pullicino, R.
Lane, S.
Radon, M. R.
Das, K. V.
Is four-dimensional CT angiography as effective as digital subtraction angiography in the detection of the underlying causes of intracerebral haemorrhage: a systematic review
title Is four-dimensional CT angiography as effective as digital subtraction angiography in the detection of the underlying causes of intracerebral haemorrhage: a systematic review
title_full Is four-dimensional CT angiography as effective as digital subtraction angiography in the detection of the underlying causes of intracerebral haemorrhage: a systematic review
title_fullStr Is four-dimensional CT angiography as effective as digital subtraction angiography in the detection of the underlying causes of intracerebral haemorrhage: a systematic review
title_full_unstemmed Is four-dimensional CT angiography as effective as digital subtraction angiography in the detection of the underlying causes of intracerebral haemorrhage: a systematic review
title_short Is four-dimensional CT angiography as effective as digital subtraction angiography in the detection of the underlying causes of intracerebral haemorrhage: a systematic review
title_sort is four-dimensional ct angiography as effective as digital subtraction angiography in the detection of the underlying causes of intracerebral haemorrhage: a systematic review
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7044254/
https://www.ncbi.nlm.nih.gov/pubmed/31901972
http://dx.doi.org/10.1007/s00234-019-02349-z
work_keys_str_mv AT denbyce isfourdimensionalctangiographyaseffectiveasdigitalsubtractionangiographyinthedetectionoftheunderlyingcausesofintracerebralhaemorrhageasystematicreview
AT chatterjeek isfourdimensionalctangiographyaseffectiveasdigitalsubtractionangiographyinthedetectionoftheunderlyingcausesofintracerebralhaemorrhageasystematicreview
AT pullicinor isfourdimensionalctangiographyaseffectiveasdigitalsubtractionangiographyinthedetectionoftheunderlyingcausesofintracerebralhaemorrhageasystematicreview
AT lanes isfourdimensionalctangiographyaseffectiveasdigitalsubtractionangiographyinthedetectionoftheunderlyingcausesofintracerebralhaemorrhageasystematicreview
AT radonmr isfourdimensionalctangiographyaseffectiveasdigitalsubtractionangiographyinthedetectionoftheunderlyingcausesofintracerebralhaemorrhageasystematicreview
AT daskv isfourdimensionalctangiographyaseffectiveasdigitalsubtractionangiographyinthedetectionoftheunderlyingcausesofintracerebralhaemorrhageasystematicreview