Cargando…
Predicting in vivo MRI Gradient-Field Induced Voltage Levels on Implanted Deep Brain Stimulation Systems Using Neural Networks
INTRODUCTION: MRI gradient-fields may induce extrinsic voltage between electrodes and conductive neurostimulator enclosure of implanted deep brain stimulation (DBS) systems, and may cause unintended stimulation and/or malfunction. Electromagnetic (EM) simulations using detailed anatomical human mode...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7044348/ https://www.ncbi.nlm.nih.gov/pubmed/32153375 http://dx.doi.org/10.3389/fnhum.2020.00034 |
_version_ | 1783501551849963520 |
---|---|
author | Erturk, M. Arcan Panken, Eric Conroy, Mark J. Edmonson, Jonathan Kramer, Jeff Chatterton, Jacob Banerjee, S. Riki |
author_facet | Erturk, M. Arcan Panken, Eric Conroy, Mark J. Edmonson, Jonathan Kramer, Jeff Chatterton, Jacob Banerjee, S. Riki |
author_sort | Erturk, M. Arcan |
collection | PubMed |
description | INTRODUCTION: MRI gradient-fields may induce extrinsic voltage between electrodes and conductive neurostimulator enclosure of implanted deep brain stimulation (DBS) systems, and may cause unintended stimulation and/or malfunction. Electromagnetic (EM) simulations using detailed anatomical human models, therapy implant trajectories, and gradient coil models can be used to calculate clinically relevant induced voltage levels. Incorporating additional anatomical human models into the EM simulation library can help to achieve more clinically relevant and accurate induced voltage levels, however, adding new anatomical human models and developing implant trajectories is time-consuming, expensive and not always feasible. METHODS: MRI gradient-field induced voltage levels are simulated in six adult human anatomical models, along clinically relevant DBS implant trajectories to generate the dataset. Predictive artificial neural network (ANN) regression models are trained on the simulated dataset. Leave-one-out cross validation is performed to assess the performance of ANN regressors and quantify model prediction errors. RESULTS: More than 180,000 unique gradient-induced voltage levels are simulated. ANN algorithm with two fully connected layers is selected due to its superior generalizability compared to support vector machine and tree-based algorithms in this particular application. The ANN regression model is capable of producing thousands of gradient-induced voltage predictions in less than a second with mean-squared-error less than 200 mV. CONCLUSION: We have integrated machine learning (ML) with computational modeling and simulations and developed an accurate predictive model to determine MRI gradient-field induced voltage levels on implanted DBS systems. |
format | Online Article Text |
id | pubmed-7044348 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-70443482020-03-09 Predicting in vivo MRI Gradient-Field Induced Voltage Levels on Implanted Deep Brain Stimulation Systems Using Neural Networks Erturk, M. Arcan Panken, Eric Conroy, Mark J. Edmonson, Jonathan Kramer, Jeff Chatterton, Jacob Banerjee, S. Riki Front Hum Neurosci Neuroscience INTRODUCTION: MRI gradient-fields may induce extrinsic voltage between electrodes and conductive neurostimulator enclosure of implanted deep brain stimulation (DBS) systems, and may cause unintended stimulation and/or malfunction. Electromagnetic (EM) simulations using detailed anatomical human models, therapy implant trajectories, and gradient coil models can be used to calculate clinically relevant induced voltage levels. Incorporating additional anatomical human models into the EM simulation library can help to achieve more clinically relevant and accurate induced voltage levels, however, adding new anatomical human models and developing implant trajectories is time-consuming, expensive and not always feasible. METHODS: MRI gradient-field induced voltage levels are simulated in six adult human anatomical models, along clinically relevant DBS implant trajectories to generate the dataset. Predictive artificial neural network (ANN) regression models are trained on the simulated dataset. Leave-one-out cross validation is performed to assess the performance of ANN regressors and quantify model prediction errors. RESULTS: More than 180,000 unique gradient-induced voltage levels are simulated. ANN algorithm with two fully connected layers is selected due to its superior generalizability compared to support vector machine and tree-based algorithms in this particular application. The ANN regression model is capable of producing thousands of gradient-induced voltage predictions in less than a second with mean-squared-error less than 200 mV. CONCLUSION: We have integrated machine learning (ML) with computational modeling and simulations and developed an accurate predictive model to determine MRI gradient-field induced voltage levels on implanted DBS systems. Frontiers Media S.A. 2020-02-20 /pmc/articles/PMC7044348/ /pubmed/32153375 http://dx.doi.org/10.3389/fnhum.2020.00034 Text en Copyright © 2020 Erturk, Panken, Conroy, Edmonson, Kramer, Chatterton and Banerjee. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Neuroscience Erturk, M. Arcan Panken, Eric Conroy, Mark J. Edmonson, Jonathan Kramer, Jeff Chatterton, Jacob Banerjee, S. Riki Predicting in vivo MRI Gradient-Field Induced Voltage Levels on Implanted Deep Brain Stimulation Systems Using Neural Networks |
title | Predicting in vivo MRI Gradient-Field Induced Voltage Levels on Implanted Deep Brain Stimulation Systems Using Neural Networks |
title_full | Predicting in vivo MRI Gradient-Field Induced Voltage Levels on Implanted Deep Brain Stimulation Systems Using Neural Networks |
title_fullStr | Predicting in vivo MRI Gradient-Field Induced Voltage Levels on Implanted Deep Brain Stimulation Systems Using Neural Networks |
title_full_unstemmed | Predicting in vivo MRI Gradient-Field Induced Voltage Levels on Implanted Deep Brain Stimulation Systems Using Neural Networks |
title_short | Predicting in vivo MRI Gradient-Field Induced Voltage Levels on Implanted Deep Brain Stimulation Systems Using Neural Networks |
title_sort | predicting in vivo mri gradient-field induced voltage levels on implanted deep brain stimulation systems using neural networks |
topic | Neuroscience |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7044348/ https://www.ncbi.nlm.nih.gov/pubmed/32153375 http://dx.doi.org/10.3389/fnhum.2020.00034 |
work_keys_str_mv | AT erturkmarcan predictinginvivomrigradientfieldinducedvoltagelevelsonimplanteddeepbrainstimulationsystemsusingneuralnetworks AT pankeneric predictinginvivomrigradientfieldinducedvoltagelevelsonimplanteddeepbrainstimulationsystemsusingneuralnetworks AT conroymarkj predictinginvivomrigradientfieldinducedvoltagelevelsonimplanteddeepbrainstimulationsystemsusingneuralnetworks AT edmonsonjonathan predictinginvivomrigradientfieldinducedvoltagelevelsonimplanteddeepbrainstimulationsystemsusingneuralnetworks AT kramerjeff predictinginvivomrigradientfieldinducedvoltagelevelsonimplanteddeepbrainstimulationsystemsusingneuralnetworks AT chattertonjacob predictinginvivomrigradientfieldinducedvoltagelevelsonimplanteddeepbrainstimulationsystemsusingneuralnetworks AT banerjeesriki predictinginvivomrigradientfieldinducedvoltagelevelsonimplanteddeepbrainstimulationsystemsusingneuralnetworks |