Cargando…
Comparison of glistenings formation and their effect on forward light scatter between the Acrysof SN60WF and Eternity Natural Uni NW-60 intraocular lenses
AIMS: To compare the characteristics of glistenings and forward light scatter between the Alcon Acrysof SN60WF and Santen Eternity Natural Uni NW-60 intraocular lenses (IOLs). METHODS: Five Acrysof SN60WF and five Eternity Natural Uni NW-60 IOLs were studied. All IOLs were single piece blue blockers...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7044831/ https://www.ncbi.nlm.nih.gov/pubmed/32154371 http://dx.doi.org/10.1136/bmjophth-2019-000399 |
_version_ | 1783501649250091008 |
---|---|
author | Philippaki, Eva O'Brart, David P Hull, Chistopher C. |
author_facet | Philippaki, Eva O'Brart, David P Hull, Chistopher C. |
author_sort | Philippaki, Eva |
collection | PubMed |
description | AIMS: To compare the characteristics of glistenings and forward light scatter between the Alcon Acrysof SN60WF and Santen Eternity Natural Uni NW-60 intraocular lenses (IOLs). METHODS: Five Acrysof SN60WF and five Eternity Natural Uni NW-60 IOLs were studied. All IOLs were single piece blue blockers with the same dioptric power (20D) and optic diameter (6.0 mm). Glistenings were induced by a thermal accelerated ageing process. Glistenings were objectively quantified using bespoke image processing software. The angular distribution of forward light scatter was measured using an optical bench system and the straylight parameter calculated from the light scatter function. RESULTS: The median increase in the number of glistenings was 15 and 525 for the Eternity and Acrysof IOLs, respectively, which was statistically significantly different (p=0.012). Median glistenings diameter was 23.8 μm (Acrysof) and 32.8 μm (Eternity). Four (80%) of the Acrysof lenses had straylight values higher than a 20-year-old CIE standard glare observer and in two cases the straylight exceeded that of the 70-year-old CIE standard glare observer. None of the Eternity lenses had straylight values that exceeded the value for the 20-year-old CIE standard glare observer. CONCLUSIONS: The Eternity Natural Uni NW-60 IOLs resisted the induction of glistenings more than the Acrysof SN60WF IOLs. Although the Acrysof IOLs developed smaller glistenings than the Eternity IOLs, there were sufficient numbers to produce a higher straylight parameter. |
format | Online Article Text |
id | pubmed-7044831 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | BMJ Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-70448312020-03-09 Comparison of glistenings formation and their effect on forward light scatter between the Acrysof SN60WF and Eternity Natural Uni NW-60 intraocular lenses Philippaki, Eva O'Brart, David P Hull, Chistopher C. BMJ Open Ophthalmol Original Research AIMS: To compare the characteristics of glistenings and forward light scatter between the Alcon Acrysof SN60WF and Santen Eternity Natural Uni NW-60 intraocular lenses (IOLs). METHODS: Five Acrysof SN60WF and five Eternity Natural Uni NW-60 IOLs were studied. All IOLs were single piece blue blockers with the same dioptric power (20D) and optic diameter (6.0 mm). Glistenings were induced by a thermal accelerated ageing process. Glistenings were objectively quantified using bespoke image processing software. The angular distribution of forward light scatter was measured using an optical bench system and the straylight parameter calculated from the light scatter function. RESULTS: The median increase in the number of glistenings was 15 and 525 for the Eternity and Acrysof IOLs, respectively, which was statistically significantly different (p=0.012). Median glistenings diameter was 23.8 μm (Acrysof) and 32.8 μm (Eternity). Four (80%) of the Acrysof lenses had straylight values higher than a 20-year-old CIE standard glare observer and in two cases the straylight exceeded that of the 70-year-old CIE standard glare observer. None of the Eternity lenses had straylight values that exceeded the value for the 20-year-old CIE standard glare observer. CONCLUSIONS: The Eternity Natural Uni NW-60 IOLs resisted the induction of glistenings more than the Acrysof SN60WF IOLs. Although the Acrysof IOLs developed smaller glistenings than the Eternity IOLs, there were sufficient numbers to produce a higher straylight parameter. BMJ Publishing Group 2020-02-12 /pmc/articles/PMC7044831/ /pubmed/32154371 http://dx.doi.org/10.1136/bmjophth-2019-000399 Text en © Author(s) (or their employer(s)) 2020. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. http://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/. |
spellingShingle | Original Research Philippaki, Eva O'Brart, David P Hull, Chistopher C. Comparison of glistenings formation and their effect on forward light scatter between the Acrysof SN60WF and Eternity Natural Uni NW-60 intraocular lenses |
title | Comparison of glistenings formation and their effect on forward light scatter between the Acrysof SN60WF and Eternity Natural Uni NW-60 intraocular lenses |
title_full | Comparison of glistenings formation and their effect on forward light scatter between the Acrysof SN60WF and Eternity Natural Uni NW-60 intraocular lenses |
title_fullStr | Comparison of glistenings formation and their effect on forward light scatter between the Acrysof SN60WF and Eternity Natural Uni NW-60 intraocular lenses |
title_full_unstemmed | Comparison of glistenings formation and their effect on forward light scatter between the Acrysof SN60WF and Eternity Natural Uni NW-60 intraocular lenses |
title_short | Comparison of glistenings formation and their effect on forward light scatter between the Acrysof SN60WF and Eternity Natural Uni NW-60 intraocular lenses |
title_sort | comparison of glistenings formation and their effect on forward light scatter between the acrysof sn60wf and eternity natural uni nw-60 intraocular lenses |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7044831/ https://www.ncbi.nlm.nih.gov/pubmed/32154371 http://dx.doi.org/10.1136/bmjophth-2019-000399 |
work_keys_str_mv | AT philippakieva comparisonofglisteningsformationandtheireffectonforwardlightscatterbetweentheacrysofsn60wfandeternitynaturaluninw60intraocularlenses AT obrartdavidp comparisonofglisteningsformationandtheireffectonforwardlightscatterbetweentheacrysofsn60wfandeternitynaturaluninw60intraocularlenses AT hullchistopherc comparisonofglisteningsformationandtheireffectonforwardlightscatterbetweentheacrysofsn60wfandeternitynaturaluninw60intraocularlenses |