Cargando…
Eosinophil counts in colonic tissue eosinophilia: Investigating specificity and sensitivity of cutoff points and comparing two counting methods
BACKGROUND/AIMS: The aim of this study was to investigate the specificity and sensitivity of eosinophil cutoff points defining the colonic tissue eosinophilia (TE) and compare the yield of reporting the highest count versus the mean of five high-power fields (HPFs). MATERIALS AND METHODS: One hundre...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7045768/ https://www.ncbi.nlm.nih.gov/pubmed/31997777 http://dx.doi.org/10.4103/sjg.SJG_381_19 |
_version_ | 1783501842042322944 |
---|---|
author | Awad, Heyam A. Abu Osba, Yousef E. Shaheen, Mohammad A. Sfeira, Ammar R. |
author_facet | Awad, Heyam A. Abu Osba, Yousef E. Shaheen, Mohammad A. Sfeira, Ammar R. |
author_sort | Awad, Heyam A. |
collection | PubMed |
description | BACKGROUND/AIMS: The aim of this study was to investigate the specificity and sensitivity of eosinophil cutoff points defining the colonic tissue eosinophilia (TE) and compare the yield of reporting the highest count versus the mean of five high-power fields (HPFs). MATERIALS AND METHODS: One hundred and seventy-one cases of colonic TE, including 22 primary eosinophilic colitis (PEC) cases, were compared to one hundred and twenty-one normal controls in the University of Jordan. The highest eosinophil count (EC) and the mean of five HPFs were recorded. The receiver operating characteristic curve (ROC) analysis was used to find the cutoff point with the best sensitivity and specificity. RESULTS: There was no significant advantage of counting five fields over counting the most densely populated HPF. Using 30 eosinophils per HPF achieved 80% sensitivity and 65% specificity. This point is close to the mean in normal controls plus one standard deviation (SD) (29 per HPF). However, there was overlap between normal counts and TE, using 30 as a cutoff point resulted in 35% false-positive rate. There was no reliable cutoff point to differentiate PEC from secondary TE. CONCLUSION: We recommend reporting the highest EC in colonic biopsies and using 30 as a cutoff point, bearing in mind the overlap with normal and correlating with the clinical team to not treat asymptomatic patients. Clinicopathological correlation is essential to separate PEC from secondary TE. |
format | Online Article Text |
id | pubmed-7045768 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-70457682020-03-12 Eosinophil counts in colonic tissue eosinophilia: Investigating specificity and sensitivity of cutoff points and comparing two counting methods Awad, Heyam A. Abu Osba, Yousef E. Shaheen, Mohammad A. Sfeira, Ammar R. Saudi J Gastroenterol Original Article BACKGROUND/AIMS: The aim of this study was to investigate the specificity and sensitivity of eosinophil cutoff points defining the colonic tissue eosinophilia (TE) and compare the yield of reporting the highest count versus the mean of five high-power fields (HPFs). MATERIALS AND METHODS: One hundred and seventy-one cases of colonic TE, including 22 primary eosinophilic colitis (PEC) cases, were compared to one hundred and twenty-one normal controls in the University of Jordan. The highest eosinophil count (EC) and the mean of five HPFs were recorded. The receiver operating characteristic curve (ROC) analysis was used to find the cutoff point with the best sensitivity and specificity. RESULTS: There was no significant advantage of counting five fields over counting the most densely populated HPF. Using 30 eosinophils per HPF achieved 80% sensitivity and 65% specificity. This point is close to the mean in normal controls plus one standard deviation (SD) (29 per HPF). However, there was overlap between normal counts and TE, using 30 as a cutoff point resulted in 35% false-positive rate. There was no reliable cutoff point to differentiate PEC from secondary TE. CONCLUSION: We recommend reporting the highest EC in colonic biopsies and using 30 as a cutoff point, bearing in mind the overlap with normal and correlating with the clinical team to not treat asymptomatic patients. Clinicopathological correlation is essential to separate PEC from secondary TE. Wolters Kluwer - Medknow 2019-02-18 /pmc/articles/PMC7045768/ /pubmed/31997777 http://dx.doi.org/10.4103/sjg.SJG_381_19 Text en Copyright: © 2019 Saudi Journal of Gastroenterology http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Awad, Heyam A. Abu Osba, Yousef E. Shaheen, Mohammad A. Sfeira, Ammar R. Eosinophil counts in colonic tissue eosinophilia: Investigating specificity and sensitivity of cutoff points and comparing two counting methods |
title | Eosinophil counts in colonic tissue eosinophilia: Investigating specificity and sensitivity of cutoff points and comparing two counting methods |
title_full | Eosinophil counts in colonic tissue eosinophilia: Investigating specificity and sensitivity of cutoff points and comparing two counting methods |
title_fullStr | Eosinophil counts in colonic tissue eosinophilia: Investigating specificity and sensitivity of cutoff points and comparing two counting methods |
title_full_unstemmed | Eosinophil counts in colonic tissue eosinophilia: Investigating specificity and sensitivity of cutoff points and comparing two counting methods |
title_short | Eosinophil counts in colonic tissue eosinophilia: Investigating specificity and sensitivity of cutoff points and comparing two counting methods |
title_sort | eosinophil counts in colonic tissue eosinophilia: investigating specificity and sensitivity of cutoff points and comparing two counting methods |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7045768/ https://www.ncbi.nlm.nih.gov/pubmed/31997777 http://dx.doi.org/10.4103/sjg.SJG_381_19 |
work_keys_str_mv | AT awadheyama eosinophilcountsincolonictissueeosinophiliainvestigatingspecificityandsensitivityofcutoffpointsandcomparingtwocountingmethods AT abuosbayousefe eosinophilcountsincolonictissueeosinophiliainvestigatingspecificityandsensitivityofcutoffpointsandcomparingtwocountingmethods AT shaheenmohammada eosinophilcountsincolonictissueeosinophiliainvestigatingspecificityandsensitivityofcutoffpointsandcomparingtwocountingmethods AT sfeiraammarr eosinophilcountsincolonictissueeosinophiliainvestigatingspecificityandsensitivityofcutoffpointsandcomparingtwocountingmethods |