Cargando…

3 Dimensional photonic scans for measuring body volume and muscle mass in the standing horse

REASONS FOR PERFORMING STUDY: Although muscle mass strongly influences performance, there is currently no effective means to measure the 3-dimensional muscle mass of horses. We evaluated a 3-dimensional (3D) scanning methodology for its ability to quantify torso and hindquarter volumes as a proxy fo...

Descripción completa

Detalles Bibliográficos
Autores principales: Valberg, Stephanie J., Borer Matsui, Amanda K., Firshman, Anna M., Bookbinder, Lauren, Katzman, Scott A., Finno, Carrie J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7046215/
https://www.ncbi.nlm.nih.gov/pubmed/32106234
http://dx.doi.org/10.1371/journal.pone.0229656
_version_ 1783501922219589632
author Valberg, Stephanie J.
Borer Matsui, Amanda K.
Firshman, Anna M.
Bookbinder, Lauren
Katzman, Scott A.
Finno, Carrie J.
author_facet Valberg, Stephanie J.
Borer Matsui, Amanda K.
Firshman, Anna M.
Bookbinder, Lauren
Katzman, Scott A.
Finno, Carrie J.
author_sort Valberg, Stephanie J.
collection PubMed
description REASONS FOR PERFORMING STUDY: Although muscle mass strongly influences performance, there is currently no effective means to measure the 3-dimensional muscle mass of horses. We evaluated a 3-dimensional (3D) scanning methodology for its ability to quantify torso and hindquarter volumes as a proxy for regional muscle mass in horses. OBJECTIVES: Determine the repeatability of 3D scanning volume (V) measurements and their correlation to body weight, estimated body volume and muscle/fat ultrasound (US) depth. METHODS: Handheld 3D photonic scans were performed on 16 Quarter Horses of known body weight 56 days apart (n = 32 scans) with each scan performed in duplicate (n = 32 replicates). Tail head fat, gluteal and longissimus dorsi muscle depths were measured using US. Processed scans were cropped to isolate hindquarter (above hock, caudal to tuber coxae) and torso (hindquarter plus dorsal thoracolumbar region) segments and algorithms used to calculate V. Torso and hindquarter volume were correlated with body weight and US using Pearson’s correlation and with estimated torso volume (50% body weight / body density) with Bland-Altman analysis. RESULTS: Scans took 2 min with < 3.5% error for duplicate scans. Torso volume (R = 0.90, P< 0.001) and hindquarter volume (R = 0.82, P< 0.001) strongly correlated with body weight and estimated BV (R = 0.91) with low bias. Torso volume moderately correlated to mean muscle US depth (R = 0.4, P< 0.05) and tail head fat (R = 0.42, P< 0.01). Mean muscle US depth moderately correlated to body weight (R = 0.50, P< 0.01). MAIN LIMITATIONS: 3D Scans determine body volume not muscle volume. CONCLUSIONS: The hand-held 3D scan provided a rapid repeatable assessment of torso and hindquarter volume strongly correlated to body weight and estimated volume. Superimposition of regional scans and volume measures could provide a practical means to follow muscle development when tail head fat depth remain constant.
format Online
Article
Text
id pubmed-7046215
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-70462152020-03-09 3 Dimensional photonic scans for measuring body volume and muscle mass in the standing horse Valberg, Stephanie J. Borer Matsui, Amanda K. Firshman, Anna M. Bookbinder, Lauren Katzman, Scott A. Finno, Carrie J. PLoS One Research Article REASONS FOR PERFORMING STUDY: Although muscle mass strongly influences performance, there is currently no effective means to measure the 3-dimensional muscle mass of horses. We evaluated a 3-dimensional (3D) scanning methodology for its ability to quantify torso and hindquarter volumes as a proxy for regional muscle mass in horses. OBJECTIVES: Determine the repeatability of 3D scanning volume (V) measurements and their correlation to body weight, estimated body volume and muscle/fat ultrasound (US) depth. METHODS: Handheld 3D photonic scans were performed on 16 Quarter Horses of known body weight 56 days apart (n = 32 scans) with each scan performed in duplicate (n = 32 replicates). Tail head fat, gluteal and longissimus dorsi muscle depths were measured using US. Processed scans were cropped to isolate hindquarter (above hock, caudal to tuber coxae) and torso (hindquarter plus dorsal thoracolumbar region) segments and algorithms used to calculate V. Torso and hindquarter volume were correlated with body weight and US using Pearson’s correlation and with estimated torso volume (50% body weight / body density) with Bland-Altman analysis. RESULTS: Scans took 2 min with < 3.5% error for duplicate scans. Torso volume (R = 0.90, P< 0.001) and hindquarter volume (R = 0.82, P< 0.001) strongly correlated with body weight and estimated BV (R = 0.91) with low bias. Torso volume moderately correlated to mean muscle US depth (R = 0.4, P< 0.05) and tail head fat (R = 0.42, P< 0.01). Mean muscle US depth moderately correlated to body weight (R = 0.50, P< 0.01). MAIN LIMITATIONS: 3D Scans determine body volume not muscle volume. CONCLUSIONS: The hand-held 3D scan provided a rapid repeatable assessment of torso and hindquarter volume strongly correlated to body weight and estimated volume. Superimposition of regional scans and volume measures could provide a practical means to follow muscle development when tail head fat depth remain constant. Public Library of Science 2020-02-27 /pmc/articles/PMC7046215/ /pubmed/32106234 http://dx.doi.org/10.1371/journal.pone.0229656 Text en © 2020 Valberg et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Valberg, Stephanie J.
Borer Matsui, Amanda K.
Firshman, Anna M.
Bookbinder, Lauren
Katzman, Scott A.
Finno, Carrie J.
3 Dimensional photonic scans for measuring body volume and muscle mass in the standing horse
title 3 Dimensional photonic scans for measuring body volume and muscle mass in the standing horse
title_full 3 Dimensional photonic scans for measuring body volume and muscle mass in the standing horse
title_fullStr 3 Dimensional photonic scans for measuring body volume and muscle mass in the standing horse
title_full_unstemmed 3 Dimensional photonic scans for measuring body volume and muscle mass in the standing horse
title_short 3 Dimensional photonic scans for measuring body volume and muscle mass in the standing horse
title_sort 3 dimensional photonic scans for measuring body volume and muscle mass in the standing horse
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7046215/
https://www.ncbi.nlm.nih.gov/pubmed/32106234
http://dx.doi.org/10.1371/journal.pone.0229656
work_keys_str_mv AT valbergstephaniej 3dimensionalphotonicscansformeasuringbodyvolumeandmusclemassinthestandinghorse
AT borermatsuiamandak 3dimensionalphotonicscansformeasuringbodyvolumeandmusclemassinthestandinghorse
AT firshmanannam 3dimensionalphotonicscansformeasuringbodyvolumeandmusclemassinthestandinghorse
AT bookbinderlauren 3dimensionalphotonicscansformeasuringbodyvolumeandmusclemassinthestandinghorse
AT katzmanscotta 3dimensionalphotonicscansformeasuringbodyvolumeandmusclemassinthestandinghorse
AT finnocarriej 3dimensionalphotonicscansformeasuringbodyvolumeandmusclemassinthestandinghorse