Proposed treatment algorithm for cardiac device-related subclavian vein stenosis: a case series

BACKGROUND: Subclavian vein obstruction may occur in patients with pacemaker leads, which may make the implantation of new pacemaker leads difficult. CASE SUMMARY: We report two cases in which upgrading to cardiac resynchronization therapy pacemaker was challenging due to total central vein occlusio...

Descripción completa

Detalles Bibliográficos
Autores principales: Lu, Wei-Da, Chen, Ju-Yi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7047064/
https://www.ncbi.nlm.nih.gov/pubmed/32128496
http://dx.doi.org/10.1093/ehjcr/ytz245
_version_ 1783502071732895744
author Lu, Wei-Da
Chen, Ju-Yi
author_facet Lu, Wei-Da
Chen, Ju-Yi
author_sort Lu, Wei-Da
collection PubMed
description BACKGROUND: Subclavian vein obstruction may occur in patients with pacemaker leads, which may make the implantation of new pacemaker leads difficult. CASE SUMMARY: We report two cases in which upgrading to cardiac resynchronization therapy pacemaker was challenging due to total central vein occlusion. In the first case, a 78-year-old woman with permanent pacemaker implantation, 5 years ago, was successfully treated by balloon venoplasty. In the second case, balloon venoplasty was unsuccessful in a 46-year-old woman who has received twice single-chamber implantable cardioverter-defibrillator, 12 years and 5 years ago, due to vessel crowding, so a contralateral side puncture, along with a tunnel technique, was performed to solve this problem. DISCUSSION: Cardiac implantable electronic device-related subclavian vein stenosis can present a challenge to common cardiac resynchronization therapy device upgrades in the absence of appropriate techniques.
format Online
Article
Text
id pubmed-7047064
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-70470642020-03-03 Proposed treatment algorithm for cardiac device-related subclavian vein stenosis: a case series Lu, Wei-Da Chen, Ju-Yi Eur Heart J Case Rep Case Reports BACKGROUND: Subclavian vein obstruction may occur in patients with pacemaker leads, which may make the implantation of new pacemaker leads difficult. CASE SUMMARY: We report two cases in which upgrading to cardiac resynchronization therapy pacemaker was challenging due to total central vein occlusion. In the first case, a 78-year-old woman with permanent pacemaker implantation, 5 years ago, was successfully treated by balloon venoplasty. In the second case, balloon venoplasty was unsuccessful in a 46-year-old woman who has received twice single-chamber implantable cardioverter-defibrillator, 12 years and 5 years ago, due to vessel crowding, so a contralateral side puncture, along with a tunnel technique, was performed to solve this problem. DISCUSSION: Cardiac implantable electronic device-related subclavian vein stenosis can present a challenge to common cardiac resynchronization therapy device upgrades in the absence of appropriate techniques. Oxford University Press 2020-01-20 /pmc/articles/PMC7047064/ /pubmed/32128496 http://dx.doi.org/10.1093/ehjcr/ytz245 Text en © The Author(s) 2020. Published by Oxford University Press on behalf of the European Society of Cardiology. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Case Reports
Lu, Wei-Da
Chen, Ju-Yi
Proposed treatment algorithm for cardiac device-related subclavian vein stenosis: a case series
title Proposed treatment algorithm for cardiac device-related subclavian vein stenosis: a case series
title_full Proposed treatment algorithm for cardiac device-related subclavian vein stenosis: a case series
title_fullStr Proposed treatment algorithm for cardiac device-related subclavian vein stenosis: a case series
title_full_unstemmed Proposed treatment algorithm for cardiac device-related subclavian vein stenosis: a case series
title_short Proposed treatment algorithm for cardiac device-related subclavian vein stenosis: a case series
title_sort proposed treatment algorithm for cardiac device-related subclavian vein stenosis: a case series
topic Case Reports
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7047064/
https://www.ncbi.nlm.nih.gov/pubmed/32128496
http://dx.doi.org/10.1093/ehjcr/ytz245
work_keys_str_mv AT luweida proposedtreatmentalgorithmforcardiacdevicerelatedsubclavianveinstenosisacaseseries
AT chenjuyi proposedtreatmentalgorithmforcardiacdevicerelatedsubclavianveinstenosisacaseseries