Cargando…

Reducing overutilisation of serum vitamin D testing at a tertiary care centre

INTRODUCTION: Testing of 25-hydroxy (25-OH) vitamin D serum levels has increased drastically in recent years and much of it is considered inappropriate based on current guidelines. METHODS: In consultation with our physician groups (experts and frequent orderers), we modified existing guidelines and...

Descripción completa

Detalles Bibliográficos
Autores principales: Tai, Felicia, Chin-Yee, Ian, Gob, Alan, Bhayana, Vipin, Rutledge, Angela
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7047492/
https://www.ncbi.nlm.nih.gov/pubmed/32098778
http://dx.doi.org/10.1136/bmjoq-2020-000929
Descripción
Sumario:INTRODUCTION: Testing of 25-hydroxy (25-OH) vitamin D serum levels has increased drastically in recent years and much of it is considered inappropriate based on current guidelines. METHODS: In consultation with our physician groups (experts and frequent orderers), we modified existing guidelines and implemented a rational policy for 25-OH vitamin D testing and 1,25 dihydroxy (1,25 di-OH) vitamin D testing at a tertiary care centre. A computer decision support tool requiring selection of one of five acceptable testing indications was created for each test as part of a computerised physician order entry system. RESULTS: As a result of our intervention, we observed a 27% decrease in the average monthly test volume for 25-OH vitamin D from 504±62 (mean±SD) tests per month to 370±33 (p<0.001). 1,25 di-OH vitamin D testing decreased 58% from 71±18 to 30±10 (p<0.001). The departments ordering the tests were similar during the preintervention and postintervention periods, and further audits, patient chart reviews and individualised physician feedback were required to ensure appropriate ordering of 1,25 di-OH vitamin D. The most common ordering reasons selected were malabsorption/dietary concerns (46%) for 25-OH vitamin D and renal failure (42%) for 1,25 di-OH vitamin D. CONCLUSIONS: Limitations of our computer decision support tool include a dependence on an honour system in selecting the testing indication and an inability to limit ordering frequency. Periodic monitoring of test volumes will be required to ensure adherence to guidelines. Despite these limitations, we have improved appropriate utilisation of these tests and reduced costs by approximately $C60 375 per year.