Cargando…

Performance evaluation of a laboratory developed PCR test for quantitation of HIV-2 viral RNA

Management of Human Immunodeficiency Virus Type 2 (HIV-2) infections present unique challenges due to low viral titers, slow disease progression, and poor response to standard antiviral therapies. The need for a nucleic acid assay to detect and quantify HIV-2 virus has led to the development of a nu...

Descripción completa

Detalles Bibliográficos
Autores principales: Jagodzinski, Linda L., Manak, Mark M., Hack, Holly R., Liu, Ying, Peel, Sheila A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7048284/
https://www.ncbi.nlm.nih.gov/pubmed/32109949
http://dx.doi.org/10.1371/journal.pone.0229424
_version_ 1783502270855380992
author Jagodzinski, Linda L.
Manak, Mark M.
Hack, Holly R.
Liu, Ying
Peel, Sheila A.
author_facet Jagodzinski, Linda L.
Manak, Mark M.
Hack, Holly R.
Liu, Ying
Peel, Sheila A.
author_sort Jagodzinski, Linda L.
collection PubMed
description Management of Human Immunodeficiency Virus Type 2 (HIV-2) infections present unique challenges due to low viral titers, slow disease progression, and poor response to standard antiviral therapies. The need for a nucleic acid assay to detect and quantify HIV-2 virus has led to the development of a number of molecular-based assays for detection and/or quantification of HIV-2 viral RNA in plasma in order to provide laboratory evidence of HIV-2 infection and viral loads for use in treatment decisions. As HIV-2 is less pathogenic and transmissible than HIV-1 and has resistance to several of the antiretroviral drugs, delay of treatment is common. Cross sero-reactivity between HIV-1 and HIV-2 makes it difficult to distinguish between the two viruses based upon serological tests. As such we developed a quantitative reverse transcription PCR (qRT-PCR) assay targeting the 5’ long terminal repeat of HIV-2 for detection and quantification of HIV-2 viral RNA in plasma to identify HIV-2 infection and for use in viral load monitoring. Serial dilutions of cultured HIV-2 virus demonstrated a wide dynamic range (10 to 100,000 copies/ml) with excellent reproducibility (standard deviation from 0.12–0.19), linearity (R(2) = 0.9994), and a lower limit of detection at 79 copies/ml (NIH-Z). The assay is highly specific for HIV-2 Groups A and B and exhibits no cross reactivity to HIV-1, HBV or HCV. Precision of the assay was demonstrated for the High (Mean = 6.41; SD = 0.12) and Medium (Mean = 4.46; SD = 0.13) HIV-2 positive controls. Replicate testing of clinical specimens showed good reproducibility above 1,000 copies/ml, with higher variability under 1,000 copies/ml. Analysis of 220 plasma samples from HIV-2 infected West African individuals demonstrated significantly lower viral loads than those observed in HIV-1 infections, consistent with results of previous studies. Slightly more than seven percent of clinical samples (7.3%) demonstrated viral loads above 100,000 copies/ml, while 37.3% of samples were undetectable. The high sensitivity, specificity, precision, and linearity of the WRAIR qRT-PCR assay makes it well suited for detection and monitoring of HIV-2 RNA levels in plasma of infected individuals.
format Online
Article
Text
id pubmed-7048284
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-70482842020-03-09 Performance evaluation of a laboratory developed PCR test for quantitation of HIV-2 viral RNA Jagodzinski, Linda L. Manak, Mark M. Hack, Holly R. Liu, Ying Peel, Sheila A. PLoS One Research Article Management of Human Immunodeficiency Virus Type 2 (HIV-2) infections present unique challenges due to low viral titers, slow disease progression, and poor response to standard antiviral therapies. The need for a nucleic acid assay to detect and quantify HIV-2 virus has led to the development of a number of molecular-based assays for detection and/or quantification of HIV-2 viral RNA in plasma in order to provide laboratory evidence of HIV-2 infection and viral loads for use in treatment decisions. As HIV-2 is less pathogenic and transmissible than HIV-1 and has resistance to several of the antiretroviral drugs, delay of treatment is common. Cross sero-reactivity between HIV-1 and HIV-2 makes it difficult to distinguish between the two viruses based upon serological tests. As such we developed a quantitative reverse transcription PCR (qRT-PCR) assay targeting the 5’ long terminal repeat of HIV-2 for detection and quantification of HIV-2 viral RNA in plasma to identify HIV-2 infection and for use in viral load monitoring. Serial dilutions of cultured HIV-2 virus demonstrated a wide dynamic range (10 to 100,000 copies/ml) with excellent reproducibility (standard deviation from 0.12–0.19), linearity (R(2) = 0.9994), and a lower limit of detection at 79 copies/ml (NIH-Z). The assay is highly specific for HIV-2 Groups A and B and exhibits no cross reactivity to HIV-1, HBV or HCV. Precision of the assay was demonstrated for the High (Mean = 6.41; SD = 0.12) and Medium (Mean = 4.46; SD = 0.13) HIV-2 positive controls. Replicate testing of clinical specimens showed good reproducibility above 1,000 copies/ml, with higher variability under 1,000 copies/ml. Analysis of 220 plasma samples from HIV-2 infected West African individuals demonstrated significantly lower viral loads than those observed in HIV-1 infections, consistent with results of previous studies. Slightly more than seven percent of clinical samples (7.3%) demonstrated viral loads above 100,000 copies/ml, while 37.3% of samples were undetectable. The high sensitivity, specificity, precision, and linearity of the WRAIR qRT-PCR assay makes it well suited for detection and monitoring of HIV-2 RNA levels in plasma of infected individuals. Public Library of Science 2020-02-28 /pmc/articles/PMC7048284/ /pubmed/32109949 http://dx.doi.org/10.1371/journal.pone.0229424 Text en https://creativecommons.org/publicdomain/zero/1.0/ This is an open access article, free of all copyright, and may be freely reproduced, distributed, transmitted, modified, built upon, or otherwise used by anyone for any lawful purpose. The work is made available under the Creative Commons CC0 (https://creativecommons.org/publicdomain/zero/1.0/) public domain dedication.
spellingShingle Research Article
Jagodzinski, Linda L.
Manak, Mark M.
Hack, Holly R.
Liu, Ying
Peel, Sheila A.
Performance evaluation of a laboratory developed PCR test for quantitation of HIV-2 viral RNA
title Performance evaluation of a laboratory developed PCR test for quantitation of HIV-2 viral RNA
title_full Performance evaluation of a laboratory developed PCR test for quantitation of HIV-2 viral RNA
title_fullStr Performance evaluation of a laboratory developed PCR test for quantitation of HIV-2 viral RNA
title_full_unstemmed Performance evaluation of a laboratory developed PCR test for quantitation of HIV-2 viral RNA
title_short Performance evaluation of a laboratory developed PCR test for quantitation of HIV-2 viral RNA
title_sort performance evaluation of a laboratory developed pcr test for quantitation of hiv-2 viral rna
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7048284/
https://www.ncbi.nlm.nih.gov/pubmed/32109949
http://dx.doi.org/10.1371/journal.pone.0229424
work_keys_str_mv AT jagodzinskilindal performanceevaluationofalaboratorydevelopedpcrtestforquantitationofhiv2viralrna
AT manakmarkm performanceevaluationofalaboratorydevelopedpcrtestforquantitationofhiv2viralrna
AT hackhollyr performanceevaluationofalaboratorydevelopedpcrtestforquantitationofhiv2viralrna
AT liuying performanceevaluationofalaboratorydevelopedpcrtestforquantitationofhiv2viralrna
AT peelsheilaa performanceevaluationofalaboratorydevelopedpcrtestforquantitationofhiv2viralrna