Cargando…

Micro-respirometry of whole cells and isolated mitochondria

Oxygen consumption is a key metric of metabolism in aerobic organisms. Current respirometric methods led to seminal discoveries despite limitations such as high sample demand, exchange with atmospheric O(2), and cumulative titration protocols leading to limited choice of useable tissue, complex data...

Descripción completa

Detalles Bibliográficos
Autores principales: Levitsky, Yan, Pegouske, David J., Hammer, Sandra S., Frantz, Nathan L., Fisher, Kiera P., Muchnik, Artem B., Saripalli, Anand R., Kirschner, Philip, Bazil, Jason N., Busik, Julia V., Proshlyakov, Denis A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society of Chemistry 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7051014/
https://www.ncbi.nlm.nih.gov/pubmed/32123561
http://dx.doi.org/10.1039/c9ra05289e
_version_ 1783502698729963520
author Levitsky, Yan
Pegouske, David J.
Hammer, Sandra S.
Frantz, Nathan L.
Fisher, Kiera P.
Muchnik, Artem B.
Saripalli, Anand R.
Kirschner, Philip
Bazil, Jason N.
Busik, Julia V.
Proshlyakov, Denis A.
author_facet Levitsky, Yan
Pegouske, David J.
Hammer, Sandra S.
Frantz, Nathan L.
Fisher, Kiera P.
Muchnik, Artem B.
Saripalli, Anand R.
Kirschner, Philip
Bazil, Jason N.
Busik, Julia V.
Proshlyakov, Denis A.
author_sort Levitsky, Yan
collection PubMed
description Oxygen consumption is a key metric of metabolism in aerobic organisms. Current respirometric methods led to seminal discoveries despite limitations such as high sample demand, exchange with atmospheric O(2), and cumulative titration protocols leading to limited choice of useable tissue, complex data interpretation, and restricted experimental design. We developed a sensitive and customizable method of measuring O(2) consumption rates by a variety of biological samples in microliter volumes without interference from the aerobic environment. We demonstrate that O(2) permeability of the photopolymer, VeroClear, is comparable to that of polyetheretherketone (0.125 vs. 0.143 barrer, respectively) providing an efficient barrier to oxygen ingress. Optical transparency of VeroClear, combined with high resolution 3D printing, allows for optode-based oxygen detection in enclosed samples. These properties yield a microrespirometer with over 100× dynamic range for O(2) consumption rates. Importantly, the enclosed respirometer configuration and very low oxygen permeability of materials makes it suitable, with resin pre-conditioning, for quantitative assessment of O(2) consumption rates at any desired [O(2)], including hyperbaric, physiological or hypoxic conditions as necessary for each cell type. We characterized two configurations to study soluble enzymes, isolated mitochondria, cells in suspension, and adherent cells cultured on-chip. Improved sensitivity allows for routine quantitative detection of respiration by as few as several hundred cells. Specific activity of cell suspensions in the microrespirometer was in close agreement with that obtained by high-resolution polarographic respirometry. Adherent cell protocols allowed for physiologically relevant assessment of respiration in retinal pigment epithelial cells, ARPE-19, which displayed lower metabolic rates compared with those in suspension. By exchanging medium composition, we demonstrate that cells can be transiently inhibited by cyanide and that 99.6% of basal O(2) uptake is recovered upon its removal. This approach is amenable to new experimental designs and precision measurements on limited sample quantities across basic research and applied fields.
format Online
Article
Text
id pubmed-7051014
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Royal Society of Chemistry
record_format MEDLINE/PubMed
spelling pubmed-70510142020-03-02 Micro-respirometry of whole cells and isolated mitochondria Levitsky, Yan Pegouske, David J. Hammer, Sandra S. Frantz, Nathan L. Fisher, Kiera P. Muchnik, Artem B. Saripalli, Anand R. Kirschner, Philip Bazil, Jason N. Busik, Julia V. Proshlyakov, Denis A. RSC Adv Chemistry Oxygen consumption is a key metric of metabolism in aerobic organisms. Current respirometric methods led to seminal discoveries despite limitations such as high sample demand, exchange with atmospheric O(2), and cumulative titration protocols leading to limited choice of useable tissue, complex data interpretation, and restricted experimental design. We developed a sensitive and customizable method of measuring O(2) consumption rates by a variety of biological samples in microliter volumes without interference from the aerobic environment. We demonstrate that O(2) permeability of the photopolymer, VeroClear, is comparable to that of polyetheretherketone (0.125 vs. 0.143 barrer, respectively) providing an efficient barrier to oxygen ingress. Optical transparency of VeroClear, combined with high resolution 3D printing, allows for optode-based oxygen detection in enclosed samples. These properties yield a microrespirometer with over 100× dynamic range for O(2) consumption rates. Importantly, the enclosed respirometer configuration and very low oxygen permeability of materials makes it suitable, with resin pre-conditioning, for quantitative assessment of O(2) consumption rates at any desired [O(2)], including hyperbaric, physiological or hypoxic conditions as necessary for each cell type. We characterized two configurations to study soluble enzymes, isolated mitochondria, cells in suspension, and adherent cells cultured on-chip. Improved sensitivity allows for routine quantitative detection of respiration by as few as several hundred cells. Specific activity of cell suspensions in the microrespirometer was in close agreement with that obtained by high-resolution polarographic respirometry. Adherent cell protocols allowed for physiologically relevant assessment of respiration in retinal pigment epithelial cells, ARPE-19, which displayed lower metabolic rates compared with those in suspension. By exchanging medium composition, we demonstrate that cells can be transiently inhibited by cyanide and that 99.6% of basal O(2) uptake is recovered upon its removal. This approach is amenable to new experimental designs and precision measurements on limited sample quantities across basic research and applied fields. The Royal Society of Chemistry 2019-10-17 /pmc/articles/PMC7051014/ /pubmed/32123561 http://dx.doi.org/10.1039/c9ra05289e Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by-nc/3.0/
spellingShingle Chemistry
Levitsky, Yan
Pegouske, David J.
Hammer, Sandra S.
Frantz, Nathan L.
Fisher, Kiera P.
Muchnik, Artem B.
Saripalli, Anand R.
Kirschner, Philip
Bazil, Jason N.
Busik, Julia V.
Proshlyakov, Denis A.
Micro-respirometry of whole cells and isolated mitochondria
title Micro-respirometry of whole cells and isolated mitochondria
title_full Micro-respirometry of whole cells and isolated mitochondria
title_fullStr Micro-respirometry of whole cells and isolated mitochondria
title_full_unstemmed Micro-respirometry of whole cells and isolated mitochondria
title_short Micro-respirometry of whole cells and isolated mitochondria
title_sort micro-respirometry of whole cells and isolated mitochondria
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7051014/
https://www.ncbi.nlm.nih.gov/pubmed/32123561
http://dx.doi.org/10.1039/c9ra05289e
work_keys_str_mv AT levitskyyan microrespirometryofwholecellsandisolatedmitochondria
AT pegouskedavidj microrespirometryofwholecellsandisolatedmitochondria
AT hammersandras microrespirometryofwholecellsandisolatedmitochondria
AT frantznathanl microrespirometryofwholecellsandisolatedmitochondria
AT fisherkierap microrespirometryofwholecellsandisolatedmitochondria
AT muchnikartemb microrespirometryofwholecellsandisolatedmitochondria
AT saripallianandr microrespirometryofwholecellsandisolatedmitochondria
AT kirschnerphilip microrespirometryofwholecellsandisolatedmitochondria
AT baziljasonn microrespirometryofwholecellsandisolatedmitochondria
AT busikjuliav microrespirometryofwholecellsandisolatedmitochondria
AT proshlyakovdenisa microrespirometryofwholecellsandisolatedmitochondria