Cargando…
Intra-Trial Reliability and Usefulness of Isometric Mid-Thigh Pull Testing on Portable Force Plates
The aim of this study was to assess the intra-trial reliability and usefulness of portable force plates and a customised Isometric Mid-Thigh Pull rig. Twenty males (age: 24.1 ± 2.5 years, body height: 177.7 ± 0.09 cm, body mass: 88.4 ± 17.9 kg) with weightlifting experience ± 12 months attended 1 fa...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Sciendo
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7052723/ https://www.ncbi.nlm.nih.gov/pubmed/32148571 http://dx.doi.org/10.2478/hukin-2019-0094 |
_version_ | 1783502913090355200 |
---|---|
author | Keogh, Ciarán Collins, D.J. Warrington, Giles Comyns, Tom |
author_facet | Keogh, Ciarán Collins, D.J. Warrington, Giles Comyns, Tom |
author_sort | Keogh, Ciarán |
collection | PubMed |
description | The aim of this study was to assess the intra-trial reliability and usefulness of portable force plates and a customised Isometric Mid-Thigh Pull rig. Twenty males (age: 24.1 ± 2.5 years, body height: 177.7 ± 0.09 cm, body mass: 88.4 ± 17.9 kg) with weightlifting experience ± 12 months attended 1 familiarisation session and 1 testing session where 4 isometric mid-thigh pulls were performed. Maximum force, absolute peak force (PF), relative PF, allometrically scaled PF, and force (150, 200, 250 ms) were deemed reliable (ICC ≥ 0.91 and CV ≤ 9.8%) based on predetermined criteria (ICC ≥ 0.8 and CV ≤ 10%). The impulse and the rate of force development (RFD) were deemed unreliable (ICC ≤ 0.91 and CV ≥ 10 %) at all time points. Maximum force, absolute PF, relative PF to body weight and body mass, rand allometrically scaled PF, had a typical error (TE) lower than the smallest worthwhile change small effect (SWC0.2) and moderate effect (SWC0.5) and were rated as good with regard to usefulness. The TE for force at selected time points (150, 200, 250 ms) was also higher than the SWC0.2, achieving a rating of marginal, but TE was higher than SWC0.5, achieving a rating of good with regard to usefulness. Portable force plates and customised rigs can reliably determine peak force and force output at different time points and for detecting the SWC in maximum and absolute force measures, greater familiarisation may be required to establish reliability of other variables such as the impulse and the RFD. |
format | Online Article Text |
id | pubmed-7052723 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Sciendo |
record_format | MEDLINE/PubMed |
spelling | pubmed-70527232020-03-06 Intra-Trial Reliability and Usefulness of Isometric Mid-Thigh Pull Testing on Portable Force Plates Keogh, Ciarán Collins, D.J. Warrington, Giles Comyns, Tom J Hum Kinet Section I - Kinesiology The aim of this study was to assess the intra-trial reliability and usefulness of portable force plates and a customised Isometric Mid-Thigh Pull rig. Twenty males (age: 24.1 ± 2.5 years, body height: 177.7 ± 0.09 cm, body mass: 88.4 ± 17.9 kg) with weightlifting experience ± 12 months attended 1 familiarisation session and 1 testing session where 4 isometric mid-thigh pulls were performed. Maximum force, absolute peak force (PF), relative PF, allometrically scaled PF, and force (150, 200, 250 ms) were deemed reliable (ICC ≥ 0.91 and CV ≤ 9.8%) based on predetermined criteria (ICC ≥ 0.8 and CV ≤ 10%). The impulse and the rate of force development (RFD) were deemed unreliable (ICC ≤ 0.91 and CV ≥ 10 %) at all time points. Maximum force, absolute PF, relative PF to body weight and body mass, rand allometrically scaled PF, had a typical error (TE) lower than the smallest worthwhile change small effect (SWC0.2) and moderate effect (SWC0.5) and were rated as good with regard to usefulness. The TE for force at selected time points (150, 200, 250 ms) was also higher than the SWC0.2, achieving a rating of marginal, but TE was higher than SWC0.5, achieving a rating of good with regard to usefulness. Portable force plates and customised rigs can reliably determine peak force and force output at different time points and for detecting the SWC in maximum and absolute force measures, greater familiarisation may be required to establish reliability of other variables such as the impulse and the RFD. Sciendo 2020-01-31 /pmc/articles/PMC7052723/ /pubmed/32148571 http://dx.doi.org/10.2478/hukin-2019-0094 Text en © 2020 Ciarán Keogh, D.J. Collins, Giles Warrington, Tom Comyns, published by Sciendo http://creativecommons.org/licenses/by-nc-nd/3.0 This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License. |
spellingShingle | Section I - Kinesiology Keogh, Ciarán Collins, D.J. Warrington, Giles Comyns, Tom Intra-Trial Reliability and Usefulness of Isometric Mid-Thigh Pull Testing on Portable Force Plates |
title | Intra-Trial Reliability and Usefulness of Isometric Mid-Thigh Pull Testing on Portable Force Plates |
title_full | Intra-Trial Reliability and Usefulness of Isometric Mid-Thigh Pull Testing on Portable Force Plates |
title_fullStr | Intra-Trial Reliability and Usefulness of Isometric Mid-Thigh Pull Testing on Portable Force Plates |
title_full_unstemmed | Intra-Trial Reliability and Usefulness of Isometric Mid-Thigh Pull Testing on Portable Force Plates |
title_short | Intra-Trial Reliability and Usefulness of Isometric Mid-Thigh Pull Testing on Portable Force Plates |
title_sort | intra-trial reliability and usefulness of isometric mid-thigh pull testing on portable force plates |
topic | Section I - Kinesiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7052723/ https://www.ncbi.nlm.nih.gov/pubmed/32148571 http://dx.doi.org/10.2478/hukin-2019-0094 |
work_keys_str_mv | AT keoghciaran intratrialreliabilityandusefulnessofisometricmidthighpulltestingonportableforceplates AT collinsdj intratrialreliabilityandusefulnessofisometricmidthighpulltestingonportableforceplates AT warringtongiles intratrialreliabilityandusefulnessofisometricmidthighpulltestingonportableforceplates AT comynstom intratrialreliabilityandusefulnessofisometricmidthighpulltestingonportableforceplates |