Cargando…

Effect of orthokeratology on precision and agreement assessment of a new swept-source optical coherence tomography biometer

BACKGROUND: To evaluate the effect of orthokeratology on precision of measurements in children using a new swept-source optical coherence tomography (SS-OCT) optical biometer (OA-2000), and agreement between its measurements and those provided by the commonly used IOLMaster based on partial coherenc...

Descripción completa

Detalles Bibliográficos
Autores principales: Shu, Bao, Bao, Fangjun, Savini, Giacomo, Lu, Weicong, Tu, Ruixue, Chen, Haisi, Song, Benhao, Wang, Qinmei, Huang, Jinhai
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7053116/
https://www.ncbi.nlm.nih.gov/pubmed/32161772
http://dx.doi.org/10.1186/s40662-020-00177-4
_version_ 1783502977481310208
author Shu, Bao
Bao, Fangjun
Savini, Giacomo
Lu, Weicong
Tu, Ruixue
Chen, Haisi
Song, Benhao
Wang, Qinmei
Huang, Jinhai
author_facet Shu, Bao
Bao, Fangjun
Savini, Giacomo
Lu, Weicong
Tu, Ruixue
Chen, Haisi
Song, Benhao
Wang, Qinmei
Huang, Jinhai
author_sort Shu, Bao
collection PubMed
description BACKGROUND: To evaluate the effect of orthokeratology on precision of measurements in children using a new swept-source optical coherence tomography (SS-OCT) optical biometer (OA-2000), and agreement between its measurements and those provided by the commonly used IOLMaster based on partial coherence interferometry (PCI). METHODS: This study recruited fifty-one eyes of 51 normal children (8–16 years). An operator took measurements with the two biometers. Then, a second operator took measurements with the SS-OCT biometer. After orthokeratology was performed for one month, the same operators repeated the same procedures. Axial length (AL), mean keratometry (Km) at 2.5 mm and 3.0 mm diameters (Km(2.5) and Km(3.0)), central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT) and corneal diameter (CD) were analyzed. RESULTS: With the SS-OCT optical biometer, the test-retest repeatability of AL measurements was < 0.06 mm. For all parameters, the coefficients of variation were < 1.23% and the intraclass correlation coefficients were > 0.95. The 95% limits of agreement of difference between the two devices for CD parameter were up to 1.53 mm. After orthokeratology, the fluctuation ranges of difference for Km3.0 measurement was 1.11 times higher than before orthokeratology, while the absolute values of difference for AL, Km2.5, ACD and CD measurements were comparable. CONCLUSIONS: Before and after orthokeratology, the SS-OCT biometer showed high repeatability and reproducibility for all measurements. Wearing orthokeratology contact lenses affected the agreement between SS-OCT and PCI biometers for Km3.0 measurements. The CD measurement showed poor agreement between the two devices.
format Online
Article
Text
id pubmed-7053116
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-70531162020-03-11 Effect of orthokeratology on precision and agreement assessment of a new swept-source optical coherence tomography biometer Shu, Bao Bao, Fangjun Savini, Giacomo Lu, Weicong Tu, Ruixue Chen, Haisi Song, Benhao Wang, Qinmei Huang, Jinhai Eye Vis (Lond) Research BACKGROUND: To evaluate the effect of orthokeratology on precision of measurements in children using a new swept-source optical coherence tomography (SS-OCT) optical biometer (OA-2000), and agreement between its measurements and those provided by the commonly used IOLMaster based on partial coherence interferometry (PCI). METHODS: This study recruited fifty-one eyes of 51 normal children (8–16 years). An operator took measurements with the two biometers. Then, a second operator took measurements with the SS-OCT biometer. After orthokeratology was performed for one month, the same operators repeated the same procedures. Axial length (AL), mean keratometry (Km) at 2.5 mm and 3.0 mm diameters (Km(2.5) and Km(3.0)), central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT) and corneal diameter (CD) were analyzed. RESULTS: With the SS-OCT optical biometer, the test-retest repeatability of AL measurements was < 0.06 mm. For all parameters, the coefficients of variation were < 1.23% and the intraclass correlation coefficients were > 0.95. The 95% limits of agreement of difference between the two devices for CD parameter were up to 1.53 mm. After orthokeratology, the fluctuation ranges of difference for Km3.0 measurement was 1.11 times higher than before orthokeratology, while the absolute values of difference for AL, Km2.5, ACD and CD measurements were comparable. CONCLUSIONS: Before and after orthokeratology, the SS-OCT biometer showed high repeatability and reproducibility for all measurements. Wearing orthokeratology contact lenses affected the agreement between SS-OCT and PCI biometers for Km3.0 measurements. The CD measurement showed poor agreement between the two devices. BioMed Central 2020-03-02 /pmc/articles/PMC7053116/ /pubmed/32161772 http://dx.doi.org/10.1186/s40662-020-00177-4 Text en © The Author(s) 2020 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Shu, Bao
Bao, Fangjun
Savini, Giacomo
Lu, Weicong
Tu, Ruixue
Chen, Haisi
Song, Benhao
Wang, Qinmei
Huang, Jinhai
Effect of orthokeratology on precision and agreement assessment of a new swept-source optical coherence tomography biometer
title Effect of orthokeratology on precision and agreement assessment of a new swept-source optical coherence tomography biometer
title_full Effect of orthokeratology on precision and agreement assessment of a new swept-source optical coherence tomography biometer
title_fullStr Effect of orthokeratology on precision and agreement assessment of a new swept-source optical coherence tomography biometer
title_full_unstemmed Effect of orthokeratology on precision and agreement assessment of a new swept-source optical coherence tomography biometer
title_short Effect of orthokeratology on precision and agreement assessment of a new swept-source optical coherence tomography biometer
title_sort effect of orthokeratology on precision and agreement assessment of a new swept-source optical coherence tomography biometer
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7053116/
https://www.ncbi.nlm.nih.gov/pubmed/32161772
http://dx.doi.org/10.1186/s40662-020-00177-4
work_keys_str_mv AT shubao effectoforthokeratologyonprecisionandagreementassessmentofanewsweptsourceopticalcoherencetomographybiometer
AT baofangjun effectoforthokeratologyonprecisionandagreementassessmentofanewsweptsourceopticalcoherencetomographybiometer
AT savinigiacomo effectoforthokeratologyonprecisionandagreementassessmentofanewsweptsourceopticalcoherencetomographybiometer
AT luweicong effectoforthokeratologyonprecisionandagreementassessmentofanewsweptsourceopticalcoherencetomographybiometer
AT turuixue effectoforthokeratologyonprecisionandagreementassessmentofanewsweptsourceopticalcoherencetomographybiometer
AT chenhaisi effectoforthokeratologyonprecisionandagreementassessmentofanewsweptsourceopticalcoherencetomographybiometer
AT songbenhao effectoforthokeratologyonprecisionandagreementassessmentofanewsweptsourceopticalcoherencetomographybiometer
AT wangqinmei effectoforthokeratologyonprecisionandagreementassessmentofanewsweptsourceopticalcoherencetomographybiometer
AT huangjinhai effectoforthokeratologyonprecisionandagreementassessmentofanewsweptsourceopticalcoherencetomographybiometer