Cargando…

Laser Ablation Electrospray Ionization Hydrogen/Deuterium Exchange Ambient Mass Spectrometry Imaging

[Image: see text] Identification and confirmation of known as well as unknown (bio)chemical entities in ambient mass spectrometry (MS) and MS imaging (MSI) mostly involve accurate mass determination, often in combination with MS/MS or MS(n) work flows. To further improve structural assignment, addit...

Descripción completa

Detalles Bibliográficos
Autores principales: van Geenen, Fred A. M. G., Claassen, Frank W., Franssen, Maurice C. R., Zuilhof, Han, Nielen, Michel W. F.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2020
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7053432/
https://www.ncbi.nlm.nih.gov/pubmed/32031404
http://dx.doi.org/10.1021/jasms.9b00082
_version_ 1783503038497947648
author van Geenen, Fred A. M. G.
Claassen, Frank W.
Franssen, Maurice C. R.
Zuilhof, Han
Nielen, Michel W. F.
author_facet van Geenen, Fred A. M. G.
Claassen, Frank W.
Franssen, Maurice C. R.
Zuilhof, Han
Nielen, Michel W. F.
author_sort van Geenen, Fred A. M. G.
collection PubMed
description [Image: see text] Identification and confirmation of known as well as unknown (bio)chemical entities in ambient mass spectrometry (MS) and MS imaging (MSI) mostly involve accurate mass determination, often in combination with MS/MS or MS(n) work flows. To further improve structural assignment, additional molecular information is required. Here we present an ambient hydrogen/deuterium exchange (HDX) laser ablation electrospray ionization (LAESI) MS method in which, apart from the accurate mass and MS/MS data, the number of exchangeable protons in (un)known molecules is obtained. While eventually presenting ambient HDX-LAESI-MSI, samples were not preincubated with deuterated solvents, but instead HDX occurred following fusion of ablated sample material with microdroplets generated by ESI of deuterated solvents. Therefore, the degree of HDX was first studied following ablation of nondeuterated sample solutions of melamine and monosaccharides. From these experiments, it was concluded that the set-up used could provide meaningful HDX data in support of molecular structure elucidation by significantly reducing the number of structure options from a measured elemental composition. This reduction was demonstrated with an unknown accurate m/z value obtained in the analysis of an orange slice, reducing the possible number of molecular structures having the same elemental composition by 87% due to the number of H/D exchanges observed. Next, deuterated and nondeuterated MS/MS experiments showed the number of exchangeable protons in the substructures from deuterated neutral losses in the product ion spectra, confirming the compound to be arginine. Finally, the potential of ambient HDX-LAESI-MSI was demonstrated by the imaging of (secondary) plant metabolites in a Phalaenopsis petal.
format Online
Article
Text
id pubmed-7053432
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-70534322020-03-04 Laser Ablation Electrospray Ionization Hydrogen/Deuterium Exchange Ambient Mass Spectrometry Imaging van Geenen, Fred A. M. G. Claassen, Frank W. Franssen, Maurice C. R. Zuilhof, Han Nielen, Michel W. F. J Am Soc Mass Spectrom [Image: see text] Identification and confirmation of known as well as unknown (bio)chemical entities in ambient mass spectrometry (MS) and MS imaging (MSI) mostly involve accurate mass determination, often in combination with MS/MS or MS(n) work flows. To further improve structural assignment, additional molecular information is required. Here we present an ambient hydrogen/deuterium exchange (HDX) laser ablation electrospray ionization (LAESI) MS method in which, apart from the accurate mass and MS/MS data, the number of exchangeable protons in (un)known molecules is obtained. While eventually presenting ambient HDX-LAESI-MSI, samples were not preincubated with deuterated solvents, but instead HDX occurred following fusion of ablated sample material with microdroplets generated by ESI of deuterated solvents. Therefore, the degree of HDX was first studied following ablation of nondeuterated sample solutions of melamine and monosaccharides. From these experiments, it was concluded that the set-up used could provide meaningful HDX data in support of molecular structure elucidation by significantly reducing the number of structure options from a measured elemental composition. This reduction was demonstrated with an unknown accurate m/z value obtained in the analysis of an orange slice, reducing the possible number of molecular structures having the same elemental composition by 87% due to the number of H/D exchanges observed. Next, deuterated and nondeuterated MS/MS experiments showed the number of exchangeable protons in the substructures from deuterated neutral losses in the product ion spectra, confirming the compound to be arginine. Finally, the potential of ambient HDX-LAESI-MSI was demonstrated by the imaging of (secondary) plant metabolites in a Phalaenopsis petal. American Chemical Society 2020-01-08 2020-02-05 /pmc/articles/PMC7053432/ /pubmed/32031404 http://dx.doi.org/10.1021/jasms.9b00082 Text en Published by the American Chemical Society. All rights reserved. This is an open access article published under a Creative Commons Non-Commercial No Derivative Works (CC-BY-NC-ND) Attribution License (http://pubs.acs.org/page/policy/authorchoice_ccbyncnd_termsofuse.html) , which permits copying and redistribution of the article, and creation of adaptations, all for non-commercial purposes.
spellingShingle van Geenen, Fred A. M. G.
Claassen, Frank W.
Franssen, Maurice C. R.
Zuilhof, Han
Nielen, Michel W. F.
Laser Ablation Electrospray Ionization Hydrogen/Deuterium Exchange Ambient Mass Spectrometry Imaging
title Laser Ablation Electrospray Ionization Hydrogen/Deuterium Exchange Ambient Mass Spectrometry Imaging
title_full Laser Ablation Electrospray Ionization Hydrogen/Deuterium Exchange Ambient Mass Spectrometry Imaging
title_fullStr Laser Ablation Electrospray Ionization Hydrogen/Deuterium Exchange Ambient Mass Spectrometry Imaging
title_full_unstemmed Laser Ablation Electrospray Ionization Hydrogen/Deuterium Exchange Ambient Mass Spectrometry Imaging
title_short Laser Ablation Electrospray Ionization Hydrogen/Deuterium Exchange Ambient Mass Spectrometry Imaging
title_sort laser ablation electrospray ionization hydrogen/deuterium exchange ambient mass spectrometry imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7053432/
https://www.ncbi.nlm.nih.gov/pubmed/32031404
http://dx.doi.org/10.1021/jasms.9b00082
work_keys_str_mv AT vangeenenfredamg laserablationelectrosprayionizationhydrogendeuteriumexchangeambientmassspectrometryimaging
AT claassenfrankw laserablationelectrosprayionizationhydrogendeuteriumexchangeambientmassspectrometryimaging
AT franssenmauricecr laserablationelectrosprayionizationhydrogendeuteriumexchangeambientmassspectrometryimaging
AT zuilhofhan laserablationelectrosprayionizationhydrogendeuteriumexchangeambientmassspectrometryimaging
AT nielenmichelwf laserablationelectrosprayionizationhydrogendeuteriumexchangeambientmassspectrometryimaging